- ML20151C645 + (11:59:12, 11 December 2024)
- ML20151C643 + (11:59:14, 11 December 2024)
- ML20151C639 + (11:59:15, 11 December 2024)
- ML20151C638 + (11:59:16, 11 December 2024)
- ML20151C633 + (11:59:18, 11 December 2024)
- ML20151C631 + (11:59:18, 11 December 2024)
- NRC-88-0084, Deletes Commitment Made in to Change Actuator on RCIC Valve F012,in Response to IE Bulletin 85-003.Design Change to RCIC Sys Will Be Implemented During Local Leak Rate Test Outage to Remove Power to RCIC Valve F012 + (11:59:20, 11 December 2024)
- ML20151C630 + (11:59:20, 11 December 2024)
- ML20151C625 + (11:59:21, 11 December 2024)
- ML20151C627 + (11:59:21, 11 December 2024)
- ML20151C622 + (11:59:25, 11 December 2024)
- ML20151C620 + (11:59:26, 11 December 2024)
- ML20151C618 + (11:59:30, 11 December 2024)
- ML20151C615 + (11:59:31, 11 December 2024)
- BECO-87-155, Forwards Response to Apparent Violations Noted in Insp Rept 50-293/87-30 & 870909 Enforcement Conference.Encl Withheld + (11:59:32, 11 December 2024)
- ML20151C614 + (11:59:32, 11 December 2024)
- ML20151C609 + (11:59:33, 11 December 2024)
- 05000334/LER-1988-001, :on 880208,steam Generator Tubes Plugged Due to Excessive Degradation.Caused by Cold Leg Support Plate thinning,U-bend Cracking & Hot Leg Support Plate Damage. Degraded Tubes Preventively Plugged + (11:59:35, 11 December 2024)
- ML20151C603 + (11:59:36, 11 December 2024)
- ML20151C597 + (11:59:37, 11 December 2024)
- ML20151C601 + (11:59:37, 11 December 2024)
- ML20151C596 + (11:59:38, 11 December 2024)
- 05000338/LER-1988-011, :on 880311,post-mod Testing Not Performed as Required by Two Tech Specs.Caused by Inadequacy of Original Engineering Work Request.Investigation Performed to Determine If Valves Been Stroke Time Tested + (11:59:40, 11 December 2024)
- ML20151C594 + (11:59:44, 11 December 2024)
- ML20151C592 + (11:59:45, 11 December 2024)
- ML20151C591 + (11:59:46, 11 December 2024)
- ML20151C587 + (11:59:47, 11 December 2024)
- ML20151C589 + (11:59:47, 11 December 2024)
- ML20151C585 + (11:59:49, 11 December 2024)
- ML20151C582 + (11:59:49, 11 December 2024)
- ML20151C580 + (11:59:50, 11 December 2024)
- ML20151C581 + (11:59:50, 11 December 2024)
- ML20151C575 + (11:59:51, 11 December 2024)
- ML20151C577 + (11:59:51, 11 December 2024)
- 05000352/LER-1988-007, :on 880309,HPCI Sys Declared Inoperable.Caused by Pressure Transmitter Failure.Transmitter Replaced & Tested & Cause for False Signal Due to Failed Amplifier Board + (11:59:53, 11 December 2024)
- ML20151C570 + (11:59:54, 11 December 2024)
- ML20151C567 + (11:59:54, 11 December 2024)
- ML20151C565 + (11:59:56, 11 December 2024)
- ML20151C562 + (11:59:57, 11 December 2024)
- ML20151C563 + (11:59:57, 11 December 2024)
- ML20151C558 + (11:59:58, 11 December 2024)
- ML20151C561 + (11:59:58, 11 December 2024)
- ML20151C557 + (11:59:59, 11 December 2024)
- 05000277/LER-1988-004, :on 880302,relay Trip Causing Breaker Trip Resulted in Containment Isolations & Inoperable Fire Pumps. Caused by Severe Heat Damage on Relay Coil.Coil Shipped to Mfg.Temporary Feed Installed + (12:00:01, 11 December 2024)
- ML20151C550 + (12:00:02, 11 December 2024)
- ML20151C555 + (12:00:02, 11 December 2024)
- ML20151C545 + (12:00:03, 11 December 2024)
- 05000213/LER-1988-007, :on 880310,RHR Sys Discovered Inoperable for More than 1 H.Operations Log Review Revealed Similar Occurrence on 880305.Caused by Failure to Observe Operating Procedures.Licensed Operators Counseled + (12:00:05, 11 December 2024)
- ML20151C541 + (12:00:06, 11 December 2024)
- ML20151C540 + (12:00:07, 11 December 2024)
- ML20151C538 + (12:00:07, 11 December 2024)
- ML20151C537 + (12:00:08, 11 December 2024)