- ML19323B499 + (04:23:37, 1 January 2025)
- 05000325/LER-1980-024-03, /03L-0:on 800405,operator Discovered Drywell Equipment Drain Integrators Indicating Flow W/Pump Secured & Respective Isolation Valve Shut.Caused by Air in Instrument Line + (04:23:41, 1 January 2025)
- ML19323B497 + (04:23:47, 1 January 2025)
- ML19323B496 + (04:23:48, 1 January 2025)
- 05000325/LER-1980-024, Forwards LER 80-024/03L-0 + (04:24:19, 1 January 2025)
- ML19323B492 + (04:24:59, 1 January 2025)
- ML19323B491 + (04:25:02, 1 January 2025)
- ML19323B488 + (04:25:36, 1 January 2025)
- 05000029/LER-1980-011-03, /03L-0:on 800407,during Maint Outage in Mode 5, Voltage Indication Lost for Fire Detection Sys.Caused by Failure of Voltage Indicating Light.Fire Patrol Established Until Sys Returned to Svc.Light Was Replaced + (04:25:40, 1 January 2025)
- ML19323B486 + (04:25:43, 1 January 2025)
- 05000029/LER-1980-011, Forwards LER 80-011/03L-0 + (04:25:47, 1 January 2025)
- 05000346/LER-1980-035-03, /03L-0:on 800410,while Attempting to Switch from Decay Heat Removal Train 1 to Train 2,cooler 2 Outlet Valve Would Not Open.Caused by Malfunctioning of Valve Operator Radial Arm.Radial Arm Was Readjusted + (04:26:19, 1 January 2025)
- ML19323B482 + (04:27:27, 1 January 2025)
- 05000346/LER-1980-035, Forwards LER 80-035/O3L-0 + (04:28:01, 1 January 2025)
- 05000325/LER-1980-035-03, /03L-0:on 800407,while Performing Reactor Low Water Level 1 Channel Calibr,Switch 1 of 1-B21-LTS-N017B&C Was Out of Tolerance.Caused by Instrument Drift.Instruments Were Calibr & Returned to Svc.Plant Mod Has Been Written + (04:29:27, 1 January 2025)
- ML19323B478 + (04:29:32, 1 January 2025)
- ML19323B476 + (04:29:34, 1 January 2025)
- 05000325/LER-1980-035, Forwards LER 80-035/03L-0 + (04:30:02, 1 January 2025)
- ML19323B473 + (04:30:07, 1 January 2025)
- 05000312/LER-1978-001, Responds to NRC Expressing Concern That 780320 Transient,Reported as LER 78-1,could Have Led to Results as Serious as Tmi.Operator Recognized That once-through Steam Generators Were Dry & Therefore Admitted Main Feedwater + (04:30:12, 1 January 2025)
- IR 05000367/1980001 + (04:30:16, 1 January 2025)
- ML19323B470 + (04:30:20, 1 January 2025)
- ML19323B469 + (04:30:22, 1 January 2025)
- ML19323B467 + (04:30:24, 1 January 2025)
- ML19323B466 + (04:30:25, 1 January 2025)
- ML19323B465 + (04:30:27, 1 January 2025)
- ML19323B463 + (04:30:28, 1 January 2025)
- ML19323B461 + (04:30:30, 1 January 2025)
- ML19323B460 + (04:30:32, 1 January 2025)
- ML19323B459 + (04:30:34, 1 January 2025)
- ML19323B457 + (04:30:35, 1 January 2025)
- ML19323B456 + (04:30:43, 1 January 2025)
- 05000259/LER-1980-030-03, /03L-0:on 800406,during Normal Operation,Hpci Steam Line Space High Temp Switch TS-73-2A Operated Incorrectly During SI 4.2.B-37.Caused by Installation of Wrong Type Switch.Switch Replaced & Tech Specs Revised + (04:31:02, 1 January 2025)
- 05000259/LER-1980-030, Forwards LER 80-030/03L-0 + (04:31:38, 1 January 2025)
- 05000346/LER-1980-034-03, /03L-0:on 800411,during Auxiliary Feed Pump Instrumentation Calibr Test,Turbine 1 Steam Inlet Pressure Switch PSL-106B Actuated at Pressure Above Setpoint.Caused by Failure of Static O-ring Pressure Switch + (04:31:55, 1 January 2025)
- ML19323B451 + (04:31:59, 1 January 2025)
- 05000346/LER-1980-034, Forwards LER 80-034/03L-0 + (04:32:01, 1 January 2025)
- 05000313/LER-1980-013-03, /03L-0:on 800407,during Reactor Trip of Offsite Power,High Pressure Injection Was Manually Initiated & CV-1227 High Pressure Injection Valve,Loop B Failed to Open on Demand.Caused by Stuck Engaging Lever + (04:32:09, 1 January 2025)
- 05000313/LER-1980-013, Forwards LER 80-013/03L-0 + (04:32:15, 1 January 2025)
- 05000348/LER-1980-027-03, /03L-0:on 800408,during Surveillance Test,Turbine First Stage Pressure Bistable PB447E Found to Trip,At Value Less than Tech Spec 3.3.2.1 Limit.Caused by Instrument Setpoint Drift.Loop Power Supply Card Adjusted + (04:32:20, 1 January 2025)
- ML19323B444 + (04:32:22, 1 January 2025)
- 05000348/LER-1980-026-03, /03L-0:on 800405,erroneous Temp Change Alarm Was Received.Upon investigation,lead-lag Card in Circuit Found to Have Unstable Output.Cause unstated.Lead-lag Card Replaced + (04:32:25, 1 January 2025)
- ML19323B442 + (04:32:28, 1 January 2025)
- ML19323B440 + (04:32:29, 1 January 2025)
- 05000029/LER-1980-010-03, /03L-0:on 800406,during Maint Outage in Mode 5, Fire Detection Sys Became Inoperable Due to Loss of Voltage. Caused by Loose Wiring Connections in Power Supply.Wiring Connectors Were Replaced.All Connectors Were Tightened + (04:32:33, 1 January 2025)
- ML19323B438 + (04:32:36, 1 January 2025)
- 05000029/LER-1980-010, Forwards LER 80-010/03L-0 + (04:32:40, 1 January 2025)
- ML19323B435 + (04:32:43, 1 January 2025)
- 05000309/LER-1980-010-03, /03L-0:on 800408,during Routine Surveillance Test of Auxiliary Feedwater Pump P-25A,small Amount of Oil Was Discharged from Pump Thrust Bearing.Cause Unknown.Personnel Have Been Instructed to Be Alert for Repetition of Event + (04:32:48, 1 January 2025)
- ML19323B433 + (04:32:51, 1 January 2025)
- 05000309/LER-1980-010, Forwards LER 80-010/03L-0 + (04:32:55, 1 January 2025)