- ENS 47988 +
- ENS 48765 +
- 05000316/LER-2002-007, Re Technical Specification 3.8.1.1 Allowed Outage Time Exceeded +
- 05000440/LER-2001-001 +
- IR 05000277/2005004 +
- ML15051A367 +
- ML17332A567 +
- ML17332A529 +
- ML17332A351 +
- ML17328A888 +
- ML17319A922 +
- ML17317B508 +
- ML083510752 +
- ENS 41832 +
- ML19345D398 +
- ML041060609 +
- ML023120013 +
- ML20080G313 +
- ML20077R303 +
- ML20097A465 +
- ML20107F654 +
- ML20137Z926 +
- ML20148L567 +
- ML20138P498 +
- IR 05000440/1999005 +
- ML20195B727 +
- ML20206P598 +
- IR 05000289/1986013 +
- ML20066B323 +
- IR 05000219/1988009 +
- ML20217C759 +
- ML20211J170 +
- ML17309A427 +
- BVY-99-102, Monthly Operating Rept for July 1999 for Vermont Yankee. with +
- IR 05000334/2021004 +
- ST-HL-AE-4283, Responds to NRC Re Violations Noted in Insp Repts 50-498/92-29 & 50-499/92-29.Corrective Actions:Engineering Will Evaluate Design Change of Sdg Circuitry to Automatically Release Sdg from Emergency Mode +
- BVY-92-079, Monthly Operating Rept for June 1992 for Vermont Yankee Nuclear Power Station +
- ML23338A191 +
- ML23338A231 +
- 05000333/LER-1989-001-01, :on 890228,ECCS Pumps Made Inoperable After Loose Motor Leads Terminal Box Discovered.Cause Apparently Due to age-related Hardening of Gasket.Bolts Replaced. Revs for Periodic Insp to Be Implemented +
- 05000373/LER-1987-032-01, :on 870917,reactor Scram Occurred on Low Reactor Water Level Signal.Caused by Difficulty of Controlling Reactor Water Level.Low Load Regulating Valve Will Be Added to Feedwater Sys +
- 05000338/LER-1987-002, :on 870213 & 16,cardreader Which Permits Access to Auxiliary Feedwater Pump House Malfunctioned & Created Potential for Unauthorized Entry to Vital Area.Cause Not Stated.Cardreader Repaired +
- 05000312/LER-1987-021, :on 861121,pressurizer Heater Bundles Damaged Following Heater Breaker Trips.Caused by Energization of Heaters W/O Adequate Water Level & Inadequate Administrative Controls.Root Cause Investigation 86-34 Issued +
- 05000341/LER-1988-023, :on 880528 & 0713,RWCU Sys Manually Isolated by Operator Action.Caused by Separate Instrument Line Compression Failures.Instrument Lines Repaired & RWCU Sys Operating Procedures Revised +
- 05000286/LER-1985-011-01, :on 851130,turbine Trip & Subsequent Reactor Trip Initiated Automatically by High Water Level in Steam Generator 32.Caused by Feedwater Perturbations During Flow Transfer Maneuvers +
- 05000498/LER-1992-016, :on 921004,unplanned ESF Actuation of Component Cooling Water Pump Occurred Due to Inadequate Procedure. CCW Surge Tank Level Recovered & CCW Sys Realigned in Accordance W/Procedure +
- 05000313/LER-1996-005-02, :on 960519,automatic Reactor Trip on High RCS Pressure Occurred.Caused by Component Failure in a MFW Pump Control Sys.Failed Speed Sensor Replaced +
- 05000336/LER-1995-014, :on 950404,continuous Fire Watch Was Found Sleeping in West 480 Volt Switchgear Room Due to Personnel Error.Posted Another Individual as Fire Watch +
- 05000338/LER-1983-049-03, /03L-0:on 830710,following Reactor Trip from 100% power,I-131 Dose Equivalent Specific Activity Exceeded 1.0 Mci/G.Caused by Minor Fuel Element Defects in Reactor Core.Sampling Frequency Accelerated +
- 05000498/LER-1993-013, :on 930408,TS 3.1.2.1 & 3.1.2.3 Violated. Caused by Use of Less than Effective Sys for Tracking Inoperable TS Equipment & Actions During Outage.Temporary Labels Placed on Control Board +