| Title | High Pressure Core Spray Declared Inoperable |
| Event Description | On February 18, 2013, at 0318 hours0.00368 days <br />0.0883 hours <br />5.257936e-4 weeks <br />1.20999e-4 months <br /> (CST), the Main Control Room received an alarm associated with a transfer of the Division 4 Nuclear System Protection System (NSPS) inverter to the alternate source. Plant Technicians were performing a Technical Specification (TS) Surveillance, 'Average Power Range Monitor Flow Biased/Neutron Flux Response Time Test,' when a test cable connector contacted a fuse block staple jumper, causing the transfer of the Division 4 NSPS bus from normal inverter source to its alternate source.
TS 3.8.7, 'Inverters - Operating' Surveillance Requirement 3.8.7.1 is not met with the inverter on the alternate source, and Condition C, requires High Pressure Core Spray (HPCS) system to be declared inoperable immediately since the Division 4 NSPS bus was not energized from the inverter. Since HPCS is an emergency core cooling system and is a single train safety system, this is a condition that could have prevented fulfillment of a safety function and is reportable under 10 CFR 50.72(b)(3)(v)(D), system needed to mitigate the consequences of an accident. At 0925 CST, the Division 4 NSPS bus has been restored to service on the normal source. At 0925 CST, HPCS has been declared Operable. The NRC Resident has been notified. |
| Where | |
|---|---|
| Clinton Illinois (NRC Region 3) | |
| Reporting | |
| 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident | |
| Time - Person (Reporting Time:+2.28 h0.095 days <br />0.0136 weeks <br />0.00312 months <br />) | |
| Opened: | Mark Dodds 11:35 Feb 18, 2013 |
| NRC Officer: | Charles Teal |
| Last Updated: | Feb 18, 2013 |
| 48765 - NRC Website
Loading map... | |
Unit 1 | |
|---|---|
| Reactor critical | Critical |
| Scram | No |
| Before | Power Operation (90 %) |
| After | Power Operation (90 %) |