Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20086N963 + (05000003)
- 05000247/LER-1983-015-03, Shutdown Initiated When Containment Spray Pump 21 Operability Criteria Not Met & Diesel Generator 23 Out of Svc for Maint.Pump 21 Removed from Svc Due to High Vibrations + (05000247)
- ML20073H005 + (05000003)
- ML20073N108 + (05000003)
- ML20069G698 + (05000003)
- ML20064D106 + (05000003)
- ML20065D290 + (05000000)
- 05000247/LER-1982-024-03, /03L-0:on 820608,charging Pump 23 Developed Leak & Declared Inoperable.Cause of Leaking Head Gasket Not Stated.Head Gasket Replaced.Pump Tested Satisfactorily & Returned to Svc + (05000247)
- 05000247/LER-1982-023-03, /03L-0:on 820606,boron Injection Tank Level Channel 944E Drifted High.Caused by Failure of Bellows Assembly of Associated Level Transmitter.Transmitter Replaced.Failed Channel Replaced W/Spare Channel 944J + (05000247)
- 05000247/LER-1982-022-03, /03L-0:on 820526,boric Acid Transfer Pump 22 Found Leaking.Caused by Failure of Mechanical Shaft Seal.New Mechanical Seal Assembly Installed + (05000247)
- ML20054L050 + (05000247)
- 05000247/LER-1982-020-03, /03L-0:on 820519,during Hot Shutdown,Turbine Driven Auxiliary Boiler Feed Pump 22 Tripped.Caused by Erratic Speed Control by Governor on Steam Turbine Drive. Governor & Governor Valve Rebuilt + (05000247)
- 05000247/LER-1982-021-03, /03L-0:on 820524,while Performing Functional Testing of Main Steam Stop Valves,Valve MS-1-22 Did Not Close within Required Time Limit.Caused by Lack of Lubrication in Valve Linkages.Linkages Lubricated + (05000247)
- 05000247/LER-1982-012-03, /03L-0:on 820309,boron Injection Tank Level Channel 944E Signal Drifted Down to 48% Level.Caused by Solidification of Boric Acid in Instrument Impulse Line Resulting in Erroneous Indication Level.Line Cleared + (05000247)
- 05000247/LER-1982-015-03, /03L-0:on 820421,during Routine Surveillance,One of Two Redundant Heat Tracing Circuits Associated W/Safety Injection Pump Train 23 Inoperable.Caused by Lead Wiring Failure.Wiring Repaired & Heaters re-energized + (05000247)
- IR 05000003/2025001 + (05000003)
- ML25156A233 + (05000247)
- ML25204A155 + (05000003)
- ML25231A152 + (05000003)
- ML25219A474 + (05000003)
- ML25268A167 + (05000003)
- ML25338A222 + (05000219)
- ML25239A010 + (05000003)
- ML25114A056 + (05000219)
- ML26015A008 + (05000003)
- ML25273A359 + (05000003)
- IR 05000003/2025003 + (05000003)
- L-25-004, Stations 1, 2, and 3, Palisades, and Big Rock Point - Nuclear Onsite Property Damage Insurance + (05000219)
- ML25346A221 + (05000003)
- ML031110094 + (05000003)
- ML14035A576 + (05000248)
- ML13069A007 + (05000248)
- ML12164A572 + (05000248)
- ML103120679 + (05000248)
- ML100260006 + (05000248)
- ML20133G837 + (05000248)
- ML20212K210 + (05000248)
- ML20237J597 + (05000248)
- ML19340A852 + (05000248)
- ML102240216 + (05000248)
- Dresden#Unit 3 + (05000249)
- 05000237/FIN-2016009-01 + (05000237)
- 05000237/FIN-2016003-02 + (05000237)
- 05000237/FIN-2016001-01 + (05000237)
- 05000237/FIN-2016004-01 + (05000237)
- 05000237/FIN-2016004-02 + (05000237)
- 05000237/FIN-2016002-01 + (05000237)
- 05000237/FIN-2016201-01 + (05000237)
- 05000249/FIN-2014002-01 + (05000249)
- 05000237/FIN-2014403-01 + (05000237)
- 05000237/FIN-2015004-01 + (05000237)
- 05000249/FIN-2015003-04 + (05000249)
- 05000237/FIN-2001021-01 + (05000237)
- 05000249/FIN-2009009-01 + (05000249)
- 05000237/FIN-2013002-02 + (05000237)
- 05000249/FIN-2014005-02 + (05000249)
- 05000249/FIN-2016010-01 + (05000249)
- 05000237/FIN-2007201-01 + (05000237)
- 05000237/FIN-2014007-01 + (05000237)
- 05000237/FIN-2017007-01 + (05000237)