05000237/FIN-2014007-01
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | Failure to Adequately Incorporate GE Operating Experience into Vendor Manual |
| Description | The inspectors identified a finding of very low safety significance and associated non-cited violation of 10 CFR Part 50, Appendix B, Criterion V, Instructions, Procedures, and Drawings, for the licensees failure to ensure that operating experience provided via a vendor Service Information Letter (SIL) was properly evaluated and incorporated into the vendor manual contrary to the requirements of procedure RSAA115, Operating Experience. The failure to properly assess operating experience for alternating current (AC) Motors resulted in a condition where specific deficiencies could go unrealized under the licensees conditioned based monitoring program. The licensee initiated action request (AR) 1633528 and 1635766 to document and develop corrective actions for the issue. The finding was determined to be more than minor because it was associated with the Mitigating Systems Cornerstone attribute of design control and affected the cornerstone objective of ensuring the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. Specifically, the failure to adequately evaluate and document the basis for the use or rejection of 9 out of 10 experiences presented in General Electric (GE) SIL 484, Supplement 6, could cause a reduction in reliability for safety related systems that use AC motors. The inspectors determined the finding could be evaluated using the SDP in accordance with IMC 0609, Significance Determination Process, Appendix A, The Significance Determination Process (SDP) for Findings At-Power. The finding was screened against the Mitigating Systems Cornerstone, Exhibit 2 of Appendix A, and determined to be of very low safety significance because the answer was no to all of the screening questions. This finding has a cross-cutting aspect in the area of Human Performance, Avoid Complacency (H.12), because individuals failed to recognize and plan for the possibility of mistakes, latent issues, and inherent risk, even while expecting successful outcomes. |
| Site: | Dresden |
|---|---|
| Report | IR 05000237/2014007 Section 4OA2 |
| Date counted | Mar 31, 2014 (2014Q1) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71152 |
| Inspectors (proximate) | C Tilton D Szwarc J Cameron J Rutkowski M Jones |
| Violation of: | 10 CFR 50 Appendix B Criterion V |
| CCA | H.12, Avoid Complacency |
| INPO aspect | QA.4 |
| ' | |
Finding - Dresden - IR 05000237/2014007 | |||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Dresden) @ 2014Q1
Self-Identified List (Dresden)
| |||||||||||||||||||||||||||||||||||||||||