- 05000280/LER-1986-026, :on 860919,quadrant-to-average-power-tilt Ratio Exceeded 2% Tech Spec Limit.Caused by Dropped Control Rod P-6 Due to Failed Stationary Gripper Coil in CRD Mechanism. Coil Replaced + (ML20215H213)
- ML20215H214 + (ML20215H214)
- 1CAN108610, Responds to Request for Addl Info Re 860718 & 31 Proposed Tech Spec Amends Concerning High Pressure Trip Setpoint & Anticipatory Reactor Trip (ART) Threshold.No Credit Taken for ART in FSAR Chapter 14 Accident Analysis + (ML20215H216)
- ML20215H217 + (ML20215H217)
- IR 05000483/1986019 + (ML20215H218)
- ML20215H221 + (ML20215H221)
- ML20215H222 + (ML20215H222)
- ML20215H223 + (ML20215H223)
- ML20215H226 + (ML20215H226)
- 05000272/LER-1986-016, :on 860805,steam Generator Feed Pump Tripped on Overspeed Trip.Caused by Failed Diode.Diode Replaced.All Four Steam Generator Feed Pump Electrical Control Panels Completely Refurbished + (ML20215H227)
- ML20215H228 + (ML20215H228)
- ML20215H229 + (ML20215H229)
- ML20215H230 + (ML20215H230)
- ML20215H231 + (ML20215H231)
- IR 05000285/1987007 + (ML20215H233)
- 05000416/LER-1986-032, :on 860916,17 & 1015,inadvertent Secondary Containment Isolations & ESF Sys Actuations Experienced Due to Outage Work Activities.Special Review Team Established to Examine Electrical tag-outs + (ML20215H235)
- 05000374/LER-1986-017-06, :on 860917,remote Shutdown Panel Instrumentation for RHR HX Svc Water Discovered Inoperable. Caused by Insufficient Review of Work Request. Instrumentation Replaced on 860918 + (ML20215H237)
- ML20215H240 + (ML20215H240)
- ML20215H241 + (ML20215H241)
- ML20215H242 + (ML20215H242)
- ML20215H244 + (ML20215H244)
- 05000374/LER-1986-016-06, :on 860914,calibr of HPCS Auto Transfer Suppression Pool High Level Switch Alarm Function Discovered Not Current.Caused by Failure to Recognize Tech Spec Requirements.Suppression Pool Alarms Added + (ML20215H245)
- 05000388/LER-1986-013-01, :on 860919,full Reactor Protection Sys Scram Occurred When Intermediate Range Monitors C & G Spiked Upscale.Caused by Noise Due to Faulty Primary Containment Penetration Connectors.Cables Rebuilt + (ML20215H247)
- ML20215H249 + (ML20215H249)
- IR 05000341/1986030 + (ML20215H252)
- ML20215H255 + (ML20215H255)
- 05000324/LER-1986-021-01, :on 860919,reactor Protection Sys Bus a Inadvertently Deenergized Due to Personnel Error.Bus Output Breakers Opened Instead of Respective Unit 1 Breakers. Personnel Disciplined + (ML20215H260)
- ML20215H263 + (ML20215H263)
- ML20215H265 + (ML20215H265)
- IR 05000313/1987002 + (ML20215H266)
- 05000373/LER-1986-022, :on 860612,shutdown Cooling Isolation Occurred During Performance of LES-PC-107 Re Group 7 Isolation Logic Sys Functional Test.Caused by Operation of Wrong Keylock Switch.Isolation Signal Reset + (ML20215H267)
- IR 05000315/1986032 + (ML20215H269)
- TXX-6024, Interim Deficiency Rept CP-86-65 Re Unconsolidated Concrete in Exterior Wall of Reactor Containment Bldg.Initially Reported on 860915.Evaluation Underway Re Effects of Concrete Void.Next Rept by 861217 + (ML20215H277)
- IR 05000498/1986038 + (ML20215H278)
- ML20215H279 + (ML20215H279)
- NUREG-1225, Submits ACRS Comments on NUREG-1225, Implementation of NRC Policy on Nuclear Power Plant Standardization, Discussed at ACRS 318th Meeting on 861009-11.Rept Should Clarify Scope & Level of Detail of Info Required for Design Certification + (ML20215H280)
- IR 05000259/1987019 + (ML20215H281)
- TXX-6028, Final Deficiency Rept CP-86-57 Re Reinforcing Steel in Facility Reactor Cavity Wall.Initially Reported on 860829. Design Restored to Condition Specified in Revised Drawing. Item Not Reportable Per 10CFR50.55(e) + (ML20215H282)
- ML20215H283 + (ML20215H283)
- TXX-6029, Final Deficiency Rept CP-86-58 Re Drilling/Cutting of Reinforcing Steel in Fuel Handling Bldg.Initially Reported on 860829.Design Change Document Revised.Item Not Reportable Per 10CFR50.55(e) + (ML20215H284)
- ML20215H285 + (ML20215H285)
- ML20215H286 + (ML20215H286)
- ML20215H287 + (ML20215H287)
- ML20215H289 + (ML20215H289)
- ML20215H290 + (ML20215H290)
- ML20215H294 + (ML20215H294)
- ML20215H297 + (ML20215H297)
- ML20215H298 + (ML20215H298)
- PNO-IV-87-016, on 870410,S&W QC Inspector Fell While Performing Fire Barrier Insp in Fuel Bldg.Inspector Not Contaminated But Received Broken Tailbone & Left Elbow + (ML20215H299)