- ML20210T610 + (ML20210T610)
- ML20210T611 + (ML20210T611)
- ML20210T614 + (ML20210T614)
- IR 05000331/1986020 + (ML20210T615)
- 05000370/LER-1986-005, :on 860326,fire Watch Patrols Not Performed as Required by Tech Spec 3.7.11.Caused by Personnel Error. Hourly Patrols Instituted & Continued Until Penetration Sealed + (ML20210T619)
- ML20210T620 + (ML20210T620)
- ML20210T621 + (ML20210T621)
- ML20210T623 + (ML20210T623)
- ML20210T625 + (ML20210T625)
- ML20210T627 + (ML20210T627)
- ML20210T629 + (ML20210T629)
- ML20210T631 + (ML20210T631)
- ML20210T632 + (ML20210T632)
- ML20210T633 + (ML20210T633)
- 3F0986-26, Responds to Violations Noted in Insp Rept 50-302/86-21. Corrective Actions:Reactor Operators Evaluated & Procedure TDP-203 Revised to Clarify Simulator Evaluation Requirements + (ML20210T635)
- ML20210T637 + (ML20210T637)
- 05000454/LER-1987-001-06, :on 870111,radioactive Release Tank Not Sampled Prior to Release Per Tech Spec 4.11.1.1.1.Caused by Personnel Error.Radiation Chemistry Technician Counseled & Tanks Relabeled + (ML20210T638)
- ML20210T641 + (ML20210T641)
- ML20210T642 + (ML20210T642)
- ML20210T645 + (ML20210T645)
- ML20210T646 + (ML20210T646)
- ML20210T650 + (ML20210T650)
- ML20210T651 + (ML20210T651)
- ML20210T654 + (ML20210T654)
- ML20210T655 + (ML20210T655)
- ML20210T658 + (ML20210T658)
- ML20210T659 + (ML20210T659)
- ML20210T660 + (ML20210T660)
- ML20210T663 + (ML20210T663)
- ML20210T664 + (ML20210T664)
- ML20210T665 + (ML20210T665)
- ML20210T668 + (ML20210T668)
- ML20210T669 + (ML20210T669)
- 3F0986-24, Responds to Violations Noted in Insp Rept 50-302/86-26. Corrective Actions:Memo Issued to Health Physics Personnel to Reemphasize Policy on Surveying for Alpha Contamination. Addl Guidance Provided in Procedure HPP-202 + (ML20210T670)
- ML20210T673 + (ML20210T673)
- ML20210T674 + (ML20210T674)
- TXX-5043, Interim Deficiency Rept CP-85-54 Re Seismic Qualification of HVAC Supports.Initially Reported on 851220.Engineering Evaluations Will Be Performed to Ensure Compliance W/Fsar Commitments.Next Rept Will Be Submitted on or About 861120 + (ML20210T675)
- TXX-4823, Interim Deficiency Rept CP-85-39 Re Conduit Not Installed Per Design Documents.Initially Reported on 850918.Review, Including Flexibility Problems of Conduit Between Raceway & Equipment,Continuing.Next Rept Expected by 860627 + (ML20210T677)
- ML20210T678 + (ML20210T678)
- ML20210T679 + (ML20210T679)
- TXX-4824, Interim Deficiency Rept CP-86-19 Re Installation of Steam Svc Pressure Transmitters Above Root Valves W/O Steam Traps or Wet Legs.Initially Reported on 860321.Evaluation of Corrective Action & Next Rept Expected by 860730 + (ML20210T683)
- ML20210T686 + (ML20210T686)
- TXX-4822, Interim Deficiency Rept CP-86-26 Re Steam Generator Upper Lateral Restraint Embedment Design.Initially Reported on 850719.Deviation from FSAR Design Criteria Evaluated Under Util Program Plan,Item V.B.Next Rept by 860627 + (ML20210T687)
- U-600704, Responds to NRC Re Violations Noted in Insp Rept 50-461/86-48.Corrective Actions:Functional Test of Annunciator Window & Computer Points Satisfactorily Completed + (ML20210T688)
- NRC-97-0083, Requests Relief from Performing Sys Leakage Test at Nominal RCS Pressure During Fall 1997 Midcycle Outage.Asme Section XI Relief Request RR-A15,encl.Util Requests That NRC Approve Relief Request No Later than 971008 + (ML20210T689)
- ML20210T690 + (ML20210T690)
- 3F0986-25, Responds to Violations Noted in Insp Rept 50-302/86-25. Corrective Actions:Senior & Nuclear Fire Protection Specialists Completed Fire Brigade Requalifications. Qualification Requirement Added to Fire Protection Program + (ML20210T691)
- IR 05000291/2010001 + (ML20210T693)
- ML20210T694 + (ML20210T694)
- ML20210T696 + (ML20210T696)
- TXX-5033, Interim Deficiency Rept CP-86-36 Re Pipe Support Mods. Initially Reported on 860609.No Addl Instances Reportable Per 10CFR50.55(e) Identified During Continuing Engineering Evaluation.Next Rept Will Be Submitted on or About 861029 + (ML20210T697)