Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000333/LER-1997-011, Forwards LER 97-011-00 Re Invalid ESF Actuation & Failure to Perform TS Required Acltions While Performing Troubleshooting Activities + (ML20202B689)
- ML20202B693 + (ML20202B693)
- ML20202B695 + (ML20202B695)
- ML20202B698 + (ML20202B698)
- ML20202B699 + (ML20202B699)
- ML20202B701 + (ML20202B701)
- ML20202B702 + (ML20202B702)
- IR 05000416/1986013 + (ML20202B703)
- ML20202B704 + (ML20202B704)
- ML20202B705 + (ML20202B705)
- ML20202B708 + (ML20202B708)
- ML20202B716 + (ML20202B716)
- ML20202B717 + (ML20202B717)
- ML20202B719 + (ML20202B719)
- ML20202B721 + (ML20202B721)
- ML20202B722 + (ML20202B722)
- ML20202B723 + (ML20202B723)
- 05000322/LER-1986-015, :on 860310,in Shutdown Mode,Continuous Fire Watch Patrol Required by Tech Spec 3.7.8 Not Kept.Caused by Watch Being Stuck in Elevator for 25 Minutes.Elevator Repaired & Fire Watch Resumed + (ML20202B725)
- ML20202B726 + (ML20202B726)
- ML20202B728 + (ML20202B728)
- 05000528/LER-1986-012, :on 860306,discovered That 860304 Surveillance Test 41ST-1ZZ16 Performed Beyond Max Allowable Time for Three Consecutive Tests.Caused by Personnel Error.Dept Guideline Developed + (ML20202B730)
- ML20202B731 + (ML20202B731)
- ML20202B739 + (ML20202B739)
- ML20202B740 + (ML20202B740)
- 3F0298-09, Provides NRC W/Actions Carried Forward as non-restart follow-up Items for Which Util Committed Future NRC Submittal or Where NRC Action on Submittal Pending + (ML20202B742)
- ML20202B746 + (ML20202B746)
- ML20202B747 + (ML20202B747)
- ML20202B753 + (ML20202B753)
- ML20202B755 + (ML20202B755)
- ML20202B758 + (ML20202B758)
- ML20202B761 + (ML20202B761)
- ML20202B763 + (ML20202B763)
- ML20202B766 + (ML20202B766)
- IR 05000482/1999001 + (ML20202B769)
- ML20202B770 + (ML20202B770)
- ML20202B772 + (ML20202B772)
- ML20202B779 + (ML20202B779)
- ML20202B784 + (ML20202B784)
- ML20202B786 + (ML20202B786)
- ML20202B788 + (ML20202B788)
- ML20202B789 + (ML20202B789)
- IR 05000313/1999002 + (ML20202B792)
- ML20202B794 + (ML20202B794)
- ML20202B796 + (ML20202B796)
- ML20202B798 + (ML20202B798)
- ML20202B800 + (ML20202B800)
- ML20202B801 + (ML20202B801)
- ML20202B802 + (ML20202B802)
- ML20202B803 + (ML20202B803)
- ML20202B804 + (ML20202B804)
- 05000528/LER-1986-034, :on 860606 & 07,operator Recorded Safety Injection Tank Level,Which Was Below Acceptable Range,W/O Taking Appropriate Action.Caused by Personnel Error.Operator Counseled + (ML20202B806)