List of results
- 05000278/LER-1998-004-03, :on 980820,automatic RWCU Isolation Occurred While Placing B RWCU Sys Demineralizer in Svc.Caused by less-than-adequate Control of Equipment.Isolated B Demineralizer & Returned RWCU Sys to Svc + (ML20153E050)
- ML20153E051 + (ML20153E051)
- ML20153E052 + (ML20153E052)
- ML20153E053 + (ML20153E053)
- ML20153E054 + (ML20153E054)
- ML20153E056 + (ML20153E056)
- ML20153E059 + (ML20153E059)
- ML20153E060 + (ML20153E060)
- ML20153E075 + (ML20153E075)
- ML20153E076 + (ML20153E076)
- ML20153E078 + (ML20153E078)
- ML20153E079 + (ML20153E079)
- ML20153E083 + (ML20153E083)
- BSEP-98-0184, Forwards Response to NRC 980617 RAI Re RPV Integrity for BSEP Units 1 & 2.Based on Review of Rept BWRVIP-46, Update of Bounding Assessment of BWR/2-6 RPV Integrity Issues Util Concluded That Listed Previously Submitted Info Valid + (ML20153E085)
- ML20153E086 + (ML20153E086)
- IR 05000029/1988002 + (ML20153E087)
- PY-CEI-NRR-0423, Updates Completion Status of Work Required by Remaining Seven Human Engineering Discrepancies Re Dcrdr Prior to Fuel Load.Discrepancies Required by Fuel Load Completed + (ML20153E090)
- ML20153E091 + (ML20153E091)
- ST-HL-AE-2607, Corrected Ltr Providing Addl Info Re ATWS Mitigating Sys Actuation Circuitry Diversity.W/O Encl + (ML20153E094)
- ML20153E096 + (ML20153E096)
- ML20153E098 + (ML20153E098)
- ML20153E100 + (ML20153E100)
- ML20153E101 + (ML20153E101)
- ML20153E104 + (ML20153E104)
- ML20153E106 + (ML20153E106)
- ML20153E107 + (ML20153E107)
- ML20153E111 + (ML20153E111)
- ML20153E112 + (ML20153E112)
- ML20153E113 + (ML20153E113)
- IR 05000354/1988006 + (ML20153E115)
- ML20153E118 + (ML20153E118)
- ML20153E121 + (ML20153E121)
- ML20153E123 + (ML20153E123)
- B17467, Submits Response to NRC RAI Re Util 980806 Proposed Rev to TS SG Tube Insp Interval (Tscr 3-17-98) + (ML20153E132)
- ML20153E137 + (ML20153E137)
- 05000321/LER-1985-046, :on 851219,at 100% Power,Spurious Initiation of Standby Gas Treatment Trains 1B & 2B Occurred.Cause Undetermined.Trains Shut Down & Returned to Standby Mode + (ML20153E138)
- 05000413/LER-1986-004, :on 860115,invalid Grab Samples Obtained.Caused by Introduction of Flush Water Over 4-day Period Due to Stuck Turbine Bldg Sump Radiation Monitor Flush Inlet Valve. on 851221,valve 1EMF Declared Inoperable + (ML20153E141)
- ML20153E148 + (ML20153E148)
- ML20153E149 + (ML20153E149)
- ML20153E151 + (ML20153E151)
- 05000280/LER-1986-003, :on 860119,at 97% Power,Reactor Tripped Manually Following Drop of Four Fuel Rods Into Core & Turbine Runback.Caused by Control Rod Logic Cabinet Jump Short.Abnormal Procedure 1.4 Changed + (ML20153E156)
- ML20153E160 + (ML20153E160)
- ML20153E161 + (ML20153E161)
- ML20153E164 + (ML20153E164)
- 05000280/LER-1986-002-01, :on 860119,at 100% Power,Excess Leakage of RCS Noted.Caused by Failed motor-operated Valve Packing & Failed Diesel Generator Diaphragm.Valve Will Be Repacked & Diaphragm Replaced During Next Suitable Outage + (ML20153E165)
- ML20153E169 + (ML20153E169)
- ML20153E171 + (ML20153E171)
- ML20153E175 + (ML20153E175)
- 05000458/LER-1986-009, Corrected LER 86-009-00:on 860114,radwaste Liquid Effluent Monitor Sample Pump Not Started During Radioactive Liquid Discharge.Caused by Miscommunication & Procedure Ambiguities.Procedures Revised + (ML20153E178)
- 05000482/LER-1988-013, :on 880802,control Room Ventilation Isolation Signal Occurred Due to Chlorine Monitor.Caused by Paper Tape Bunching Up on Chlorine Monitor.Paper Tape Replaced & No Further Problems Identified W/Monitor + (ML20153E179)