- ML20151S143 + (ML20151S143)
- ML20151S145 + (ML20151S145)
- ML20151S147 + (ML20151S147)
- ML20151S155 + (ML20151S155)
- ML20151S157 + (ML20151S157)
- ML20151S159 + (ML20151S159)
- IR 05000285/1988019 + (ML20151S161)
- 05000251/LER-1986-001, :on 860101,auxiliary Feedwater Pumps a & C Started Due to Valve 4-10-320 Not Being Seated Properly. Caused by Broken Guide Stud on Valve.Valve Repaired in Accordance W/Nrc Disposition & Tested + (ML20151S162)
- ML20151S165 + (ML20151S165)
- ML20151S167 + (ML20151S167)
- ML20151S172 + (ML20151S172)
- ML20151S175 + (ML20151S175)
- ML20151S183 + (ML20151S183)
- ML20151S189 + (ML20151S189)
- ML20151S191 + (ML20151S191)
- ML20151S193 + (ML20151S193)
- ML20151S198 + (ML20151S198)
- ML20151S203 + (ML20151S203)
- ML20151S206 + (ML20151S206)
- ML20151S207 + (ML20151S207)
- ML20151S208 + (ML20151S208)
- ML20151S212 + (ML20151S212)
- ML20151S213 + (ML20151S213)
- NSD-NRC-98-5760, Forwards Rev 25 to GW-GL-021, AP600 SSAR, Vols 1-11. Revised Tables of Contents,Change Page Instructions,List of Effective Pages,Document Cover Sheet & Change Roadmap Outlining Changes in Each Section Also Encl + (ML20151S217)
- ML20151S219 + (ML20151S219)
- ML20151S220 + (ML20151S220)
- IR 05000267/1988005 + (ML20151S225)
- ML20151S226 + (ML20151S226)
- ML20151S227 + (ML20151S227)
- ML20151S229 + (ML20151S229)
- ML20151S233 + (ML20151S233)
- ML20151S240 + (ML20151S240)
- ML20151S241 + (ML20151S241)
- IR 05000259/1988020 + (ML20151S243)
- JPN-98-039, Forwards Response to Request for Addl Info Re Response to GL 92-01, Reactor Pressure Vessel Integrity. Ltr Includes New Commitments + (ML20151S244)
- JPN-88-013, Requests Registration as User of Models CNS 1-13C,CNS 1-13G, CNS 3-55,CNS 8-120A & CNS 8-120B + (ML20151S245)
- ML20151S246 + (ML20151S246)
- ML20151S247 + (ML20151S247)
- ML20151S249 + (ML20151S249)
- ML20151S251 + (ML20151S251)
- ML20151S257 + (ML20151S257)
- 05000295/LER-1997-022-01, Forwards LER 97-022-01,IAW 10CFR50.73(a)(2)(v).Commitments Made within Ltr,Encl + (ML20151S259)
- ML20151S261 + (ML20151S261)
- ML20151S263 + (ML20151S263)
- ML20151S267 + (ML20151S267)
- ML20151S269 + (ML20151S269)
- ML20151S270 + (ML20151S270)
- ML20151S273 + (ML20151S273)
- ML20151S276 + (ML20151S276)
- 05000267/LER-1988-011, :on 880706,core Support Floor Vent Valve, V-111063,not Full Open Following Reactor Shutdown & Depressurization.Caused by Failure of Set Screw in Valve. V-111063 Will Be Repaired/Replaced + (ML20151S277)