Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20141N918 + (ML20141N918)
- ML20141N919 + (ML20141N919)
- 05000269/LER-1986-003-02, :on 860208,discovered That Effluent Grab Sample from Chemical Treatment Pond 3 Missed.Caused by Personnel Oversight & Misentry Into Log Book.Personnel Counseled. Procedures Will Be Clarified + (ML20141N920)
- 05000331/LER-1986-004, :on 860212,RWCU Sys Isolated Due to High Differential Temp Indication.Caused by Minor Degradation of Manual Valves on Vent & Drain Lines of Regenerative HX A. Valves Tightened + (ML20141N922)
- ML20141N923 + (ML20141N923)
- ML20141N925 + (ML20141N925)
- ML20141N926 + (ML20141N926)
- ML20141N927 + (ML20141N927)
- ML20141N930 + (ML20141N930)
- 05000339/LER-1986-002-02, :on 860220,during Mode 3,reactor Tripped on source-range Neutron Detectors N-35 & N-36 High Flux.Cause Unstated.Detectors Returned to Svc.Investigation Continuing + (ML20141N931)
- IR 05000508/1986002 + (ML20141N932)
- ML20141N933 + (ML20141N933)
- ML20141N938 + (ML20141N938)
- ML20141N939 + (ML20141N939)
- ML20141N940 + (ML20141N940)
- ML20141N941 + (ML20141N941)
- 05000267/LER-1986-013, :on 860212,Surveillance SR 5.2.7a1-A/5.3.4a1-A, Originally Scheduled on 850120,performed.Caused by Personnel Error.Shift Supervisors Instructed to Identify Specific Operational Limits When Rescheduling + (ML20141N942)
- 05000454/LER-1986-009, :on 860222,during Cold Shutdown,Containment Vent Isolation Occurred Due to Undervoltage Condition at Radiation Monitors 1RT-AR011 & 1RT-AR012.Caused by Voltage Transient on 345 Kv Distribution Sys + (ML20141N944)
- ML20141N945 + (ML20141N945)
- PM-86-064, Forwards LERs 86-007,86-008 & 86-009 + (ML20141N946)
- ML20141N947 + (ML20141N947)
- 05000322/LER-1986-007, :on 860212,split of Reactor Bldg Closed Loop Cooling Water (RBCLCW) Into Accident Configuration Occurred Due to lo-lo RBCLCW Head Tank a Level.Caused by Inadequate Station Procedure for Filling Hxs.Procedure Being Revised + (ML20141N948)
- 05000322/LER-1986-008, :on 860214,during Surveillance Procedure,Split of Reactor Bldg Closed Loop Cooling Water (RBCLCW) Sys Occurred.Caused by Technician Accidentally Bumping RBCLCW Head Tank B lo-lo Level Switch.Procedure Revised + (ML20141N949)
- ML20141N950 + (ML20141N950)
- 05000322/LER-1986-009, :on 860217,during APRM Functional Test,Full Reactor Trip Occurred.Caused by Technician Failure to Reset Reactor Protection Sys Trip Signal a Before Initiating Test of Logic Train B.Procedures Being Reviewed + (ML20141N951)
- ML20141N952 + (ML20141N952)
- 05000416/LER-1986-004, :on 860212,reactor Scrammed During Shutdown for Excessive Reactor Coolant Leakage.Caused by Deterioration of Seal on Reactor Recirculation Pump B.Seal Replaced + (ML20141N953)
- ML20141N954 + (ML20141N954)
- 05000389/LER-1986-004-02, :on 860210,discovered That Max Allowable Time Interval Exceeded for 31-day in-core Alarm Setpoint Surveillance.Caused by Personnel Error.Surveillance Performed + (ML20141N955)
- ML20141N957 + (ML20141N957)
- 05000270/LER-1985-004, :on 850422,reactor Trip Occurred on Loss of Main Feedwater.Caused by Loss of Motor Control Ctrs 2XC & 2XB Due to Two Grounded Terminal Boards.Grounded Terminal Boards Replaced + (ML20141N958)
- ML20141N959 + (ML20141N959)
- ML20141N962 + (ML20141N962)
- 05000286/LER-1985-008-01, :on 851018,boric Acid Concentrations Outside Tech Spec Limits.Caused by Difficulties Encountered by Plant Operators When Performing Precipitation Checks.Boric Acid Check Added to Plant Operator Training Program + (ML20141N963)
- ML20141N964 + (ML20141N964)
- ML20141N965 + (ML20141N965)
- ML20141N966 + (ML20141N966)
- ML20141N967 + (ML20141N967)
- ML20141N969 + (ML20141N969)
- ML20141N970 + (ML20141N970)
- 05000245/LER-1983-004, :on 830207,during Performance of Diesel Generator Operational Readiness Demonstration,Diesel Failed to Start.Caused by Failure of Air Start Solenoids to Open Due to Rust.Piston Assemblies Cleaned + (ML20141N971)
- ML20141N972 + (ML20141N972)
- ML20141N973 + (ML20141N973)
- ML20141N974 + (ML20141N974)
- ML20141N975 + (ML20141N975)
- ML20141N976 + (ML20141N976)
- ML20141N977 + (ML20141N977)
- 05000423/LER-1986-014, :on 860210,reactor Trip Signal Received When Level in Steam Generator 2 Decreased to low-low Level Trip Setpoint.Caused by Personnel Error.Temporary Leads in Use Removed.Correct Leads Installed + (ML20141N978)
- ML20141N979 + (ML20141N979)
- ML20141N980 + (ML20141N980)
- ML20141N981 + (ML20141N981)