Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20135G197 + (ML20135G197)
- ML20135G198 + (ML20135G198)
- ML20135G202 + (ML20135G202)
- ML20135G204 + (ML20135G204)
- ML20135G205 + (ML20135G205)
- ML20135G206 + (ML20135G206)
- ML20135G211 + (ML20135G211)
- ML20135G218 + (ML20135G218)
- ML20135G226 + (ML20135G226)
- ML20135G232 + (ML20135G232)
- ML20135G233 + (ML20135G233)
- ML20135G234 + (ML20135G234)
- ML20135G236 + (ML20135G236)
- ML20135G237 + (ML20135G237)
- ML20135G249 + (ML20135G249)
- ML20135G272 + (ML20135G272)
- 05000293/LER-1985-022, :on 850812,part of Maint Hot Shop Ventilation Contaminated & Provided Unmonitored Release Path to Environ. Caused by Design Inadequacy.Associated Fan & Breaker Tagged & Ductwork Inlet Sealed + (ML20135G279)
- 05000413/LER-1985-050, :on 850807,both Discharge Headers of Fire Protection Pumps Isolated.Caused by Personnel Error.Ry Header Unisolated & Accountable Engineer Changed Chlorination Loop Designations on Flow Diagram + (ML20135G296)
- 05000325/LER-1985-045, :on 850815,spurious Upscale Trip of Reactor Power Intermediate Range Monitor Occurred.Caused by Electronic Noise Spike on Intermediate Range Monitor Channel D Circuitry.Channels Reset + (ML20135G298)
- ML20135G300 + (ML20135G300)
- ML20135G301 + (ML20135G301)
- 05000327/LER-1985-032-01, :on 850816,both Trains of Emergency Gas Treatment Sys Declared Inoperable Due to Failure to Meet Environ Qualification for Instrumentation.Setpoint Change Initiated + (ML20135G303)
- ML20135G304 + (ML20135G304)
- 05000373/LER-1985-060-01, :on 850813,ammonia & Chlorine Detectors for Train a of Control Room/Auxiliary Electrical Equipment Room HVAC Sys Tripped.Caused by Momentary Loss of Power to Sys. Power Restored + (ML20135G305)
- 05000338/LER-1985-014, :on 850909,station Employee W/Restricted Clearance Had Unauthorized Access to Station Vital Areas. Caused by Improperly Encoded Key Card.New Badge Number Issued to Employee.Key Cards Checked + (ML20135G310)
- ML20135G313 + (ML20135G313)
- ML20135G315 + (ML20135G315)
- ML20135G317 + (ML20135G317)
- 05000373/LER-1985-061-01, :on 850814,diesel Generator 1A Not Run within 1 H of Generator 2A Being Declared Inoperable.Caused by Difficulty in Interpreting Tech Spec Requirements.Diesel Generator 1A Run & Tech Spec 3.8.1 Revised + (ML20135G321)
- 05000341/LER-1985-050, :on 850814,reactor Water Cleanup Sys Isolated. Caused by Spurious Actuation of Temp Switches in Reactor Water Cleanup Sys Steam Leak Detection Sys.Engineering Evaluating Sys to Prepare Design Change + (ML20135G322)
- ML20135G325 + (ML20135G325)
- 05000311/LER-1985-017, :on 850808,during Testing of Solid State Protection Sys Train B,Reactor Trip Occurred.Caused by Loose Wire Supplying Power to Undervoltage Trip Mechanism for Reactor Trip Breaker A.Wire Tightened + (ML20135G326)
- 05000265/LER-1985-017-05, :on 850815,reactor Water Cleanup Sys Shut Down. Caused by Failed Cleanup Nonregenerative HX Outlet High Temp Switch.Defective Power Supply Replaced & Calibr Temp Switch Calibr + (ML20135G327)
- ML20135G328 + (ML20135G328)
- ML20135G330 + (ML20135G330)
- ML20135G331 + (ML20135G331)
- ML20135G332 + (ML20135G332)
- 05000315/LER-1985-041, :on 850813,Loop 1 Feedwater Isolation Valve Failed to Close Upon Receipt of Safety Injection Signal. Caused by Inadequate Terminated Lead at Terminal Block. Procedural Requirements Should Prevent Events + (ML20135G333)
- ML20135G334 + (ML20135G334)
- ML20135G335 + (ML20135G335)
- ML20135G340 + (ML20135G340)
- JAFP-85-0706, Effluent & Waste Disposal Semiannual Rept,Jan-June 1985 + (ML20135G341)
- 05000255/LER-1985-010, :on 850811,reactor Trip Occurred from Loss of Generator Load.Caused by Erratic Response in motor-operated auto-transformer (Mot) During Voltage Adjustment,Resulting in Underexcitation of Generator.Mot Replaced + (ML20135G343)
- ML20135G344 + (ML20135G344)
- ML20135G350 + (ML20135G350)
- IR 05000395/1985028 + (ML20135G358)
- IR 05000302/1985012 + (ML20135G362)
- 05000255/LER-1984-017, :on 840903,LPSI Flow Control Valve CV-3006 (Fcv:Bp) Not Fully Open.Caused by Misadjusted Packing During Refurbishing of Valve in 1983 & 1984 + (ML20135G368)
- ML20135G371 + (ML20135G371)
- ML20135G372 + (ML20135G372)
- ML20135G384 + (ML20135G384)