- 3F0885-10, Special Rept 85-03:on 850807,discovered That mid- & high- Range Channels of Gaseous Effluent Release Monitors Out of Calibr.Caused by Delays in Contractual Arrangements for Supplies.Action Taken to Obtain Matls.Part 21 Related + (ML20135D391)
- IR 05000483/1996014 + (ML20135D392)
- ML20135D394 + (ML20135D394)
- ML20135D395 + (ML20135D395)
- ML20135D397 + (ML20135D397)
- ML20135D399 + (ML20135D399)
- ML20135D401 + (ML20135D401)
- ML20135D402 + (ML20135D402)
- ML20135D403 + (ML20135D403)
- ML20135D404 + (ML20135D404)
- IR 05000295/1996018 + (ML20135D406)
- ML20135D410 + (ML20135D410)
- ML20135D412 + (ML20135D412)
- ML20135D413 + (ML20135D413)
- ML20135D416 + (ML20135D416)
- ML20135D417 + (ML20135D417)
- ML20135D418 + (ML20135D418)
- IR 05000382/1996024 + (ML20135D421)
- ML20135D426 + (ML20135D426)
- ML20135D434 + (ML20135D434)
- ML20135D436 + (ML20135D436)
- ML20135D438 + (ML20135D438)
- ML20135D439 + (ML20135D439)
- ML20135D441 + (ML20135D441)
- ML20135D442 + (ML20135D442)
- ML20135D443 + (ML20135D443)
- IR 05000302/1985018 + (ML20135D444)
- 05000312/LER-1984-019, :on 840608,Tech Specs Violated When Diesel Generators No Longer in Ambient State Prior to Tests Being Performed.Caused by Rev to Procedures EM.177A & B.Maint Startup Deleted from Procedures + (ML20135D445)
- IR 05000155/1996012 + (ML20135D446)
- ML20135D447 + (ML20135D447)
- ML20135D448 + (ML20135D448)
- ML20135D449 + (ML20135D449)
- IR 05000268/1984036 + (ML20135D450)
- ML20135D451 + (ML20135D451)
- 05000304/LER-1984-030-04, :on 841210,while Replacing Switch for Portion of Containment Isolation Phase a Circuitry on Train A,Two Leads Accidentally Shorted Together,Opening All Five Train a Isolation Valve Seal Water Valves + (ML20135D453)
- ML20135D454 + (ML20135D454)
- ML20135D458 + (ML20135D458)
- ML20135D460 + (ML20135D460)
- ML20135D461 + (ML20135D461)
- 05000304/LER-1984-005-04, :on 840215,during Maint,Instrument Five Valve Test Manifold for 2PDT-RV85 Found W/Equalizing Valve Open. Cause Not Stated.Manifold to Be Replaced W/Single Valve. Verification Being Conducted Weekly + (ML20135D463)
- ML20135D464 + (ML20135D464)
- ML20135D466 + (ML20135D466)
- ML20135D467 + (ML20135D467)
- ML20135D468 + (ML20135D468)
- ML20135D470 + (ML20135D470)
- 05000295/LER-1985-030-04, :on 850802,all Three Penetration Pressurization Air Compressors Auto Started Due to Low Supply Pressure from Instrument Air Sys.Caused by Spurious High Vibration Trip of 2A Instrument Air Compressor + (ML20135D472)
- 05000280/LER-1984-011-03, :on 840518,operations Personnel Performing Sys Walkdown Following Maint Discovered Intended Heat Sink for Charging Pump Component Cooling Water Sys Isolated.Caused by Inadequate Procedures + (ML20135D474)
- HL-5270, Application for Amend to License NPF-5,revising SLMCPR Values Based Upon Unique plant-evaluations for Current Cycle 13 & Use of GE Fuel in Next Cycle 14 + (ML20135D478)