O f" " %r UNITE D ST ATES

/

.ft NUCLEAR REGULATORY COMMISSION j q

'

r.

2, 3s r.

g REGloN IV

,

SA

_.

/

611 RY AN PLAZA DRIVE, SUIT E 400

'%,.....#

ARLINGTON TEXAS 76011 8064 FEB271997 Donald F. Schnell, Senior Vice President - Nuclear Union Electric Company P.O. Box 66149 St. Louis, Missouri 63166-6149 SUBJECT: NRC INSPECTION REPORT 50-483/96-14 Thank you for your letter of February 10,1997,in response to our letter and Notice of Violation dated January 16,1997. We have reviewed your reply and find it responsive to the concerns raised in our Notice of Violation. In addition to the corrective actions you describe in your letter, we understand you will also continue to review opportunities for improvement in the labeling of fuses outside the facility power block. We will review the implementation of your corrective actions during a future inspection to determine that full compliance has been achieved and will be maintained.

Sincerely,

"

.L I

Arthur. Howell111,' Acting Director

j Division of Reactor Projects Docket No.: 50-483 License No.: NPF-30 cc:

Professional Nuclear Consulting, Inc.

- 19041 Raines Drive Derwood, Maryland 20855 (

Gerald Charnoff, Esq.

Thomas A. Baxter, Esq.

Shaw, Pittman, Potts & Trowbridge 2300 N. Street, N.W.

Washington, D.C. 20037 m"'nn33 appappp'sau 9703050218 970227

'

    • -

PDR ADOCK 05000483

PDR

-

. _.

_

.

~.._ _

_ _ _ _.

. -

-

_.

.

.

.

Union Electric Company-2-H. D. Bono, Supervising Engineer Site Licensing Union Electric Company P.O. Box 620 Fulton, Missouri 65251 G. L. Randolph, Vice President Nuclear Operations Union Electric Company P.O. Box 620 Fulton, Missouri 65251

twanager - Electric Department

,

Missouri Public Service Commiss?on 301 W. High

P.O. Box 360 Jefferson City, Missouri 65102 Ronald A. Kucera, Deputy Director Department of Natural Resources P.O. Box 176 Jefferson City, Missouri 65102 Otto L. Maynard, President and Chief Executive Officer Wolf Creek Nuclear Operating Corporation P.O. Box 411 Burlington, Kansas 66839 Dan 1. Bolef, President Kay Drey, Representative Board of Directors Coalition for the Environment 6267 Delmar Boulevard University City, Missouri 63130 l

Lee Fritz, Presiding Commissioner Callaway County Court House l

10 East Fifth Street l

Fulton, Missouri 65151 l

l

. - - -

-

.

- -.

-

.-

--

-.

.

l l

l.

!

i Union Electric Company-3-

Alan C. Passwater, Manager Licensing and Fuels Union Electric Company P.O. Box 66149 St. Louis, Missouri 63166-6149 J. V. Laux, Manager Quality Assurance Union Dectric Company P.O. Box 320 l

Fulton, Missouri 65251

I l

.

,

!

Union Electric Company-4-FEB 271997

,

I f

bec to DCD (IE01)

i bec distrib. by RIV:

Regional Administrator Resident inspector J

DRP Director DRS-PSB

Branch Chief (DRP/B)

MIS System Project Engineer (DRP/B)

RIV File Branch Chief (DRP/TSS)

Leah Tremper (OC/LFDCB, MS: TWFN 9E10)

i i

DOCUMENT NAME: R:\\_CW\\CW614AK.DP To receive copy of document, indicate in boxgC" = Copy without enclosures

"E" = Copy with enclosures "N" = No copy RIV:DRP/B C:DRP/B /

/

AD:Q{g?,

DNGraves;df h WDJohns5pf ATtOifvb1$

J 2/p /97 2/7797 V 2tq /97 *

OFFICIAL RECORD COPY

.... _ _... -. - -. - - -

.

- -.

- -....

-

.. -.....

-

- -.. -

.

!:

!

.:-

.

l Union Electric Company-4-FEB 271997 i

l l

l

..

.

l bec to DCD (IE01)

bec distrib. by RIV:

Regional Administrator Resident inspector DRP Director DRS-PSB l

Branch Chief (DRP/B) -

MIS System l

Project Engineer (DRP/B)

RIV File

,

l Branch Chief (DRP/TSS)

Leah Tremper (OC/LFDCB, MS: TWFN 9E10)

'

!

.

I

!

l l

!

l l

l l

l l

f l

!

t DOCUMENT NAME: R:\\_CW\\CW614AK.DP

'

To receive copy of document, Indicate in bougC" = Copy weout enclosures

"E" = Copy we enclosures "N" = No copy RIV:DRP/B C:DRP/B [

/

AD:Q{pf,

{

DNGraves;df,$

WDJohns5p'

ATl46%b11p f

2/p /97 2/2797 V 2/ q /97 *

'

t OFFICIAL RECORD COPY s

l

,

e n.

-. --

-.. -

-

.--

,

., -

-, - - ~.

,

,.---,,,n-

-

.

1901 Chaureau Aven Po. t Gi!>cc 6u 149 St ioua. M=cw: 6?*-

314 554 2550

'

Umon

-

c...i" ~ "

Etscrnic j.+;; ':- ~ cm E

'? I 3.

'

Febniary 10,1997 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Mail Stop PI-137 Washington, DC 20555-0001 ULNRC-3523 Gentlemen:

REPLY TO NOTICE OF VIOLATION INSPECTION REPORT NO. 50-483/96014 CALLAWAY PLANT This responds to Mr. James E. Dyer's letter dated January 16,1997, which transmitted a Notice of Violation for events discussed in Inspection Report 50-483/96014. Our response to the violation is presented in the attachment.

None of the material in the response is considered proprietary by Union Electric.

If you have any questions regarding this response, or if additional information is required, please let me know.

Very truly yours,

/

Donald F. Schnell DFS/tmw Attachment: 1) Response to Violation M n( \\ 7 0

.

ULNRC-3523 February 10,1997

..

Page 2

~

cc: Mr. James E. Dyer Regional Administrator U.S. Nuclear Regulatory Commission Region IV 611 Ryan Plaza Drive, Suite 400 Arlington, TX 76011-8064 Senior Resident Inspector Callaway Resident Office U.S. Nuclear Regulatory Commission

8201 NRC Road l

Steedman,MO 65077 Ms. Kristine M. Thomas (2 copies)

Licensing Project Manager, Callaway Plant Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Mail Stop 13E16 Washington, DC 20555-2738 Manager, Electric Department Missouri Public Service Commission PO Box 360 Jefferson City, MO 65102 Mr. Thomas A. Baxter Shaw, Pittman, Potts, & Trowbridge 2300 N. Street N.W.

Washington, DC 20037 Manager, Plant Support Wolf Creek Nuclear Operating Corporation PO Box 411 Burlington,KS 66839 J

_

__ __ _ _. _ _ _. _ _ _. _ _ _ _ _ _ _. _. _

_. _ _ _ _ _

v i

l

"

-

Attachment to i '-

ULNRC-3523 h*

February 10,1997 l

Page1 i

[

Statement of Violation

)-

During an NRC inspection conducted November 24,1996 through January 4,1997, a t

i violation ofNRC requirements was identi6ed. In accordance with the " General Statement i

of Policy and Procedures for NRC Enforcement Actions," (60 FR 34381; June 30,1995)

I the violation is listed below:

>

l

Callaway Plant Technical Speci6 cation 6.8.1 states, in part, that written procedures

)

i shall be established, implemented, and maintained covering the applicable procedures

recommended in Appendix A ofRegulatory Guide 1.33, Revision 2, February 1978.

l

!

Regulatory Guide 1.33, Appendix A,1.c requires, in part, that administrative procedures be written for equipment control tagging.

i Administrative Procedure ODP-ZZ-00310, " Workman's Protection Assurance

!

Tagging," Revision 2, Step 4.1.10.3, required that the method and order specified on

!

the tagout control sheet be followed when hanging tcgs.

a L

j Contrary to the above, on Deceminr 18,1996, the equipment operator pulled the

incorrect fuses when hanging a tag specified on Workman's Protection Assurance j

tagout control sheet 21672. This personnel error resulted in tripping a circulating l

water pump and a service water pump requiring a power reduction to avoid a turbine j

trip on loss ofvacuum (483/96014-01).

l This is a Severity Level IV violation (Supplement 1).

-

l Reason for the Violation The cause of the violation was determined to be personnel error by a non-licensed j

Equipment Operr.or (EO) when placing Workman's Protection Assurance (WPA) tags j

for tagout control sheet 21672. It was determined the EO was working in cabinet PB12102 instead of PB12104 as speci6ed by the tagout control sheet. The EO thought he

]

l was pulling the secondary fuses for transformer XPB121, when in fact he was pulling the l-secondary fuses for bus PB122, which resulted in the trip of the 'B' circulating water pump and the 'B' service water pump.

Corrective Steps Taken and Results Achieved:

The 'A' Essential Service Water Pump was started to supply service water loads and licensed Reactor Operators reduced power to 92% to minimize the condenser pressure increase. The 'B' circulating water pump was restarted. Plant systems responded as expected. An Event Review Team was assembled. A corrective action document, SOS.

96-1992 was initiated to document and track corrective actions associated with this event.

WPA tagout 21672 was reviewed and veri 6ed to be correct.

'

.

_

_

.

- - _.

_ _.

_.

_-

.

Att:chment to

.

ULNRC-3523

,

February 10,1997

-

Page 2 Corrective Steps to Avoid Further Violations:

The event was reviewed with EOs on shift. " Attention to Detail" was stressed for placement of WPA.

Operations requalification training cycle 97-0 willinclude use of a Stop, Thmk, Act, and Review (STAR) Trainer. This is a control panel simulator that is designed to challenge self checking performance. The simulator provides a hands-on approach to emphasize E

attention to detail in performance of tasks. Operations requalification training cycle 97-1 will include management expectations for placement of WPA as well as a review of this event.

Date when Full ComDiiance will be Achieved:

Full compliance will be achieved upon completion of Operations requalification training.

Training cycle 97-0 will be completed by March 15,1997. Training cycle 97-1 will be completed by May 1,1997.

,

f

!

i 1