- 05000374/LER-1984-054, :on 840818,isolations of Reactor Water Cleanup Occurred.Under Same Conditions,Two Other Reactor Water Cleanup Isolations Occurred.Caused by High Differential Flow.Corrective Actions Under Review + (ML20098D674)
- ML20098D675 + (ML20098D675)
- ML20098D676 + (ML20098D676)
- ML20098D685 + (ML20098D685)
- ML20098D686 + (ML20098D686)
- ML20098D695 + (ML20098D695)
- ML20098D699 + (ML20098D699)
- 05000461/LER-1992-006, :on 920425,containment & Drywell Instrument Air Sys Isolation Valves Closed Unexpectedly.Caused by Design of Instrument Air Isolation Logic.Mod to Change Logic Will Be Evaluated + (ML20098D709)
- ML20098D711 + (ML20098D711)
- 05000259/LER-1984-032-01, :on 840814,during Core Spray Logic Test, Solenoid Which Controls Air to Actuator of Inboard Isolation Valve Caused Actuator to Hold Check Valve in Open Position. Caused by Personnel Error.Solenoid Repaired + (ML20098D712)
- ML20098D714 + (ML20098D714)
- ML20098D715 + (ML20098D715)
- ML20098D717 + (ML20098D717)
- ML20098D718 + (ML20098D718)
- ML20098D722 + (ML20098D722)
- ML20098D725 + (ML20098D725)
- ML20098D729 + (ML20098D729)
- Press Release-I-20-002, NRC to Conduct Public Webinar on April 21 to Discuss Indian Point Nuclear Power Plant Decommissioning Topics + (ML20098D730)
- ML20098D733 + (ML20098D733)
- ML20098D735 + (ML20098D735)
- ML20098D736 + (ML20098D736)
- 05000373/LER-1992-006-04, :on 920427,determined That Design Setpoint of 4 Kv Degraded Voltage Relays May Be Insufficient to Assure Proper Operation.On 920429,discovered That HPCS Pump Cooler Fan Voltage Lower than Required + (ML20098D737)
- ML20098D738 + (ML20098D738)
- ML20098D739 + (ML20098D739)
- 05000265/LER-1992-013, :on 920423,determined That Degraded Voltage Setpoints Nonconservative,Based on Preliminary Calculations. Caused by Faulty Calculation Methodology.Second Level Voltage Relays Replaced + (ML20098D741)
- ML20098D743 + (ML20098D743)
- ML20098D749 + (ML20098D749)
- 05000324/LER-1984-010-01, :on 840827,during Refueling/Maint Outage, Automatic Trip of Both Reactor Protection Sys Channels a & B Occurred.Caused by Possible Welding or Mechanical Shock During Outage + (ML20098D756)
- 05000254/LER-1992-014-02, :on 920424,determined That LPCI Valves Would Not Open During Degraded Voltage Condition Due to Improper Setting of Trip Setpoints.Caused by Design Error.Valve Contactors Replaced + (ML20098D760)
- CNL-20-031, Supplement to Application to Revise Watts Bar Nuclear Plant (Wbn), Unit 2 Technical Specifications for Steam Generator Tube Repair Sleeve (WBN-TS-391-1913) + (ML20098D779)
- ML20098D780 + (ML20098D780)
- ML20098D786 + (ML20098D786)
- ML20098D801 + (ML20098D801)
- ML20098D802 + (ML20098D802)
- ML20098D830 + (ML20098D830)
- RBG-18893, Final Deficiency Rept DR-196 Re Five Undersized Fillet Welds for Battery Rack 1EB*BAT01A.Uncorrected Condition Would Not Affect Safety of Plant.Item Not Reportable Under 10CFR50.55(e) + (ML20098D834)
- W3P84-2547, Fifth Interim Significant Const Deficiency Rept 108 Re Potential Failure to Comply W/Fsar Safe Shutdown Commitment. Next Rept Delayed Until 840928 + (ML20098D853)
- W3P84-2552, Third Interim Significant Const Deficiency Rept 114 Re Possible Damage to safety-related Equipment Due to Water Hammers.Next Rept Delayed Until 840921 + (ML20098D855)