Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20096G100 + (ML20096G100)
- 05000374/LER-1984-044-01, :on 840801,reactor Water Cleanup Isolated on High Differential Flow.Caused by Lifted Relief Valve Combined W/Reactor Start Up.Work Request Written to Investigate Relief Valve Problem + (ML20096G103)
- ML20096G106 + (ML20096G106)
- 05000424/LER-1992-002-03, :on 920424,potential for Delays in Cycling ESFAS Sequencer Discovered & Sequencers Operated Outside Design Basis.Circuitry Defeated & Vendor Plan of Action Being Developed + (ML20096G108)
- 05000425/LER-1992-006-01, :on 920428,upstream Loop 4 MSIV Opened,Causing Level in SG to Swell & Resulting in Feedwater Isolation. Caused by Procedure Inadequacy.Procedure Revised to Ensure Appropriate Steamline Temp + (ML20096G123)
- 05000374/LER-1984-047, :on 840805,digital Volt Meter Inadvertently Connected Causing Turbine Control Valves to Shut & Reactor to Scram on High Neutron Flux.Caused by Personnel Error. Personnel Retrained on Startup Procedures + (ML20096G128)
- 05000424/LER-1992-003-03, :on 920502,high Level Radiation Alarm Annunciated for Fuel Handling Bldg Radiation Monitors & Fuel Handling Bldg Isolation Occurred.Cause Not Determined. Performance Monitoring Will Continue + (ML20096G137)
- 05000425/LER-1992-007-01, :on 920429,SG Level Transmitter 2LT-553 Momentarily Spiked Offscale High,Causing Main Feedwater Sys Isolation.Caused by Drain Valve for Level Transmitter Partially Open.Valve Closed & Plug Tightened + (ML20096G152)
- ML20096G155 + (ML20096G155)
- 05000368/LER-1992-004-01, :on 920412,foreign Matl Discovered in EDG Fuel Oil Tank.Caused by Inadequate Cleanliness & Foreign Matl Exclusion Controls.Foot Valve in Fuel Oil Day Tank Removed & Cleaned & Fuel Oil Filters Replaced + (ML20096G160)
- 05000302/LER-1992-003-03, :on 910801,determined That Two Procedures for Documenting Vol of Fuel Stored in DG Fuel Oil Storage Tank Erroneously Revised.Caused by Procedure Rev Error. Relationship of Suction Point Will Be Verified + (ML20096G161)
- ML20096G165 + (ML20096G165)
- ML20096G171 + (ML20096G171)
- ML20096G172 + (ML20096G172)
- ML20096G175 + (ML20096G175)
- ML20096G188 + (ML20096G188)
- ML20096G195 + (ML20096G195)
- ML20096G199 + (ML20096G199)
- ML20096G210 + (ML20096G210)
- ML20096G219 + (ML20096G219)
- 05000338/LER-1984-007-01, :on 840802,17 Cycle 4 Fuel Assemblies Determined to Be Leaking Based on Sipping Exams.Possibly Caused by Primary Hydriding,Debris Induced Fretting,Weld & Stress Related Defects.Evaluation Incomplete + (ML20096G227)
- ML20096G232 + (ML20096G232)
- ST-HL-AE-4103, Advises That Aw Harrison Will Represent Util at 920623 & 24 NRC Current Licensing Basis Workshop.Recommended Topics for Discussion Listed + (ML20096G252)
- ML20096G258 + (ML20096G258)
- ML20096G259 + (ML20096G259)
- ML20096G261 + (ML20096G261)
- 05000361/LER-1984-042, :on 840730,spurious Toxic Gas Isolation Sys Actuation Occurred.Caused by Overly Conservative Alarm Setpoints.Tech Spec Amend Requesting More Appropriate Setpoints Proposed + (ML20096G264)
- ML20096G265 + (ML20096G265)
- B14141, Submits Schedule Change for Installation of Alternate Ac Source,Per Station Blackout Rule (10CFR50.63).New DG & Associated Equipment Scheduled to Be Delivered in Fall 1992 & Testing Will Be Completed During 1993 Refueling Outage + (ML20096G266)
- ML20096G272 + (ML20096G272)
- ML20096G278 + (ML20096G278)
- 05000397/LER-1984-083, :840802,manual Scram Implemented Due to High Reactor Water Conductivity.Caused by Condenser Water in Leakage.Condenser Tube Plugged & Sys Returned to Svc + (ML20096G279)
- 05000254/LER-1984-005-02, :on 840414,insps Revealed Several Welds W/ Circumferential &/Or Axial Linear Indications & Areas W/ Small Cracks.Caused by Igscc.Welds Repaired + (ML20096G291)
- ML20096G326 + (ML20096G326)
- 05000397/LER-1984-081, :on 840816 & 18,reactor Water Cleanup & RCIC Sys Isolations Occurred During Surveillance of Leak Detection Sys Temp Monitor.Caused by Logic Switch in Normal Position.Isolation Signal Reset + (ML20096G338)
- ML20096G341 + (ML20096G341)
- 05000338/LER-1984-006-03, :on 840801,air Cooling & Purging Sys Galvanized Ductwork & Supports Improperly Coated to Mitigate Corrosion. Caused by Insufficient Controls Due to Ductwork Painting Designated nonsafety-related + (ML20096G343)
- RBG-36852, Special Rept:On 920517,employee Sustained Head Injury in Drywell.Employee Considered Contaminated Because Area Was Contaminated.Subsequent Surveys of Injured Employee Found No Contamination + (ML20096G344)
- ML20096G353 + (ML20096G353)
- ML20096G354 + (ML20096G354)
- ML20096G388 + (ML20096G388)
- ML20096G389 + (ML20096G389)
- ML20096G406 + (ML20096G406)
- ELV-03730, Informs That Corrections to Rev 14 Commitments Will Be as Indicated on Encl Emergency Plan Pages,Per 920429 Telcon + (ML20096G424)
- ML20096G432 + (ML20096G432)
- ML20096G453 + (ML20096G453)
- 05000361/LER-1992-007, :on 920226,TDAFWP P-140 Tripped on Overspeed During Startup for Inservice Test Surveillance.Caused by Introduction of Accumulated Condensed Steam Into Pump Turbine.Replaced Clogged Steam Trap Strainer + (ML20096G461)
- ML20096G467 + (ML20096G467)
- ML20096G470 + (ML20096G470)
- U-601980, Forwards Rev 0 to Clinton Power Station Raw Water Treatment & Enhancement Program, as Followup to 900129, 1231 & 910404 Responses to Generic Ltr 89-13, Svc Water Sys Problems Affecting Safety-Related Equipment + (ML20096G492)
- ML20096G499 + (ML20096G499)