.W i:

~

Arizona Public Service Company August 23, 1984 ANPP-30307-TDS/TRB U. S. Nuclear Regulatory Commission Region V

' Cteekside Oaks Office Park 1450 Maria Lane - Suite 210 Walnut Creek,' CA 94596-5368 Attention: Mr. T. W. Bishop, Director Division of Resident Reactor Projects and Engineering Programs

Subject:

Time Extension For Report - DER 84-38 A 50.55(e) Potentially Reportable Deficiency Relating To Itaproperly Welded Flange In Unit 2.

File: 84-019-026; D.4.33.2

Reference:

(A) Telephone conversation between P. Narbut and T. Bradish on May 25, 1984 (B) ANPP-29814, dated June 25, 1984 (Interim Report)

Dear Sir:

The NRC was notified of a potentially. reportable deficiency in Reference (A), and an Interim Report was transmitted by Reference (B).

At that time, it was estimated that a Final Report would be available by August 24, 1984.

Due to the extensive investigation and evaluation required, it is now expected that this information will be finalized by October 2,1984, at which time a complete report will be submitted.

There is no new information or change to the Interim Report at this time.

Very truly yours, b

cm g{

~-

E. E. Van Brunt, Jr.

APS Vice President i

Nuclear Production ANPP Project Director

'Ni H0193u EEVB/TRB/nj cc: See Page Two

  1. lllii' jg

- 8409100344 840823-PDR ADOCK 05000529 Ol>;f 8

PDR Q3g3

- [O c5j

r-

  • 3

' s-

/

Mr. T.LW.-Bishop DER 84-38 Page Two-cc:

- Richard DeYoung, Director.

Office of Inspection and Enforcement U.. S.. Nuclear Regulatory Commission Washington, D. C. 20555 T. G. Woods, Jr.

D. B. Karner W. E. Ide D. B. Fasnacht A. C. Rogers L. A. Souza D. E. Fowler T. D. Shriver C. N. Russo J. Vorees J. R. Bynum J. M. Allen J. A. Brand A. C. Gehr W. J. Stubblefield W. G. Bingham R. L. Patterson R. W. Welcher H. D. Foster D. R. Hawkinson L. E. Vorderbrueggen R. P. Zimmerman S. R. Prost J. Self M. Woods T. J. Bloom D. Canady Records Center Institute of Nuclear Power Operations 1100 circle 75 Parkway, Suite 1500 Atlanta, GA 30339