Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20091C224 + (ML20091C224)
- ML20091C233 + (ML20091C233)
- ML20091C235 + (ML20091C235)
- ML20091C236 + (ML20091C236)
- JAFP-91-0455, Forwards Engineering Assessment Turbine Bldg Fire Area IE Ja Fitzpatrick Nuclear Power Plant, to Support App R Exemption for area-wide Detection in Turbine Bldg + (ML20091C244)
- ML20091C247 + (ML20091C247)
- JAFP-91-0454, Forwards Engineering Assessment,Battery Room Corridor,Ja Fitzpatrick Nuclear Power Plant, to Support 10CFR50,App R Exemption for area-wide Suppression in Battery Room Corridor + (ML20091C252)
- ML20091C257 + (ML20091C257)
- ST-HL-AE-4037, Special Rept Re Evaluation of Unit 2 Third Yr Containment Tendon Surveillance.Refilling of Grease Accomplished Simultaneously W/Discoveries of Voids as Result of Insp Process Used + (ML20091C260)
- ML20091C270 + (ML20091C270)
- ML20091C286 + (ML20091C286)
- ML20091C289 + (ML20091C289)
- ML20091C299 + (ML20091C299)
- 05000254/LER-1992-007-01, :on 920228,control Room Isolation Dampers Closed & Ventilation Sys Automatically Entered Recirculation Mode.Caused by Inadequate Calibr & Probe Fitting Procedure. Analyzer Will Be Repaired & Procedures Revised + (ML20091C323)
- 0CAN039210, Forwards ANI Certificates of Insurance for Maelu Policies 92143,X92143R & Neilia Policy X91-002 as Evidence of Primary & Excess Onsite Property Damage Insurance Coverage + (ML20091C324)
- ML20091C338 + (ML20091C338)
- ML20091C341 + (ML20091C341)
- ML20091C344 + (ML20091C344)
- ML20091C348 + (ML20091C348)
- ML20091C352 + (ML20091C352)
- ML20091C358 + (ML20091C358)
- ML20091C359 + (ML20091C359)
- 05000259/LER-1992-002-02, :on 920302,unplanned ESF Actuations Occurred, Resulting from Short in Indicating Light Socket.Caused by Adequate Design Requirement.Esfs Reset to Normal Configuration + (ML20091C361)
- ML20091C363 + (ML20091C363)
- ML20091C377 + (ML20091C377)
- ML20091C378 + (ML20091C378)
- ML20091C393 + (ML20091C393)
- ML20091C405 + (ML20091C405)
- ML20091C412 + (ML20091C412)
- ML20091C414 + (ML20091C414)
- ML20091C420 + (ML20091C420)
- ML20091C440 + (ML20091C440)
- PLA-2218, Ro:On 840323,results of Filtration Sys Test,Following Painting in Reactor Bldg,Revealed Charcoal in Equipment Compartment Exhaust Charcoal Absorbers 2F257A & B Required Replacement.Work Authorization Issued + (ML20091C442)
- ML20091C445 + (ML20091C445)
- ML20091C454 + (ML20091C454)
- ML20091C464 + (ML20091C464)
- ST-HL-AE-3826, Forwards Endorsements 3,8,9,10,11 & 12 to Maelu Policy M-113,Endorsements 1-5 & 7-12 to Maelu Policy M-116, Endorsements 2,3,7,8,9 & 10 to Nelia Policy N-113 & Endorsements 1-10 to Nelia Policy N-116 + (ML20091C465)
- ML20091C467 + (ML20091C467)
- ML20091C468 + (ML20091C468)
- AECM-84-0261, Responds to NRC Re Violations Noted in IE Insp Rept 50-416/84-07.Corrective Actions:Matrix/Punchlist Developed to Track Correct Status of Emergency Preparedness Training of Plant Personnel,Per Procedure 01-S-04-21 + (ML20091C470)
- ML20091C472 + (ML20091C472)
- ML20091C476 + (ML20091C476)
- ML20091C482 + (ML20091C482)
- ML20091C498 + (ML20091C498)
- ML20091C501 + (ML20091C501)
- ML20091C502 + (ML20091C502)
- 1CAN058405, Submits Info Re Reactor Trip Breaker Shunt Trip Installation,In Response to NRC 840124 & 27 Ltrs.Shunt Trip Operable from Automatic Reactor Protection Signal & Tested on Monthly Basis Using safety-related Procedures + (ML20091C513)
- ML20091C516 + (ML20091C516)
- ML20091C522 + (ML20091C522)
- RBG-35-397, Requests Permission to Operate Facility Addl 5000 Hours Until Fourth Refueling Outage W/O Reperforming Exam of N4A-2 Feedwater Nozzle to safe-end Weld & That NRC Amend Safety Evaluation Reflecting Info Contained in Encl Rept + (ML20091C526)
- 3F0484-22, Forwards Revised Response to NRC Re Violations Noted in IE Insp Rept 50-302/84-02.Corrective Actions: Personnel Counseled on Importance of Procedural Adherence & Procedure CH-338 Revised + (ML20091C533)