- ML20086Q770 + (ML20086Q770)
- 05000281/LER-1975-004-01, /01T:on 750214,steam Generator C Narrow Range Level Channel 1 Indication Found Drifted High.Caused by Leaking Condensate Pot Isolation Valve Preventing Pot from Maintaining Proper Water Level + (ML20086Q776)
- ML20086Q780 + (ML20086Q780)
- ML20086Q790 + (ML20086Q790)
- 05000280/LER-1975-007-01, /01T:on 750313,uncontrolled & Unplanned Release of Low Level Radioactive Matl Made to Discharge Canal.Caused by Personnel Oversight.Operators Reinstructed on Maintaining Proper Control & Documentation + (ML20086Q792)
- ML20086Q794 + (ML20086Q794)
- ML20086Q802 + (ML20086Q802)
- ML20086Q810 + (ML20086Q810)
- 05000280/LER-1975-006, Supplemental LER 75-06/010:on 750215,module S/N D401 Failed Due to Capacitor C-37 Being Open Circuit.Capacitors Replaced + (ML20086Q811)
- 05000280/LER-1975-006-01, /01T:on 750215 & 19,channel 1 Overpower Setpoint Failed High.Caused Under Investigation.Low Level Amplifier TM-1-412A Replaced & Instrument Calibr Performed + (ML20086Q814)
- ML20086Q817 + (ML20086Q817)
- ML20086Q818 + (ML20086Q818)
- ML20086Q822 + (ML20086Q822)
- ML20086Q825 + (ML20086Q825)
- ML20086Q829 + (ML20086Q829)
- ML20086Q836 + (ML20086Q836)
- ML20086Q837 + (ML20086Q837)
- ML20086Q846 + (ML20086Q846)
- 05000280/LER-1975-005-01, /01T:on 750214,pressurizer Pressure Comparator Found Out of Calibr.Caused by Component Failure of Hagan Computer Sys Model 118 Signal Comparator A56Y 4111082-001. Comparator Replaced + (ML20086Q850)
- ML20086Q854 + (ML20086Q854)
- ML20086Q877 + (ML20086Q877)
- ML20086Q883 + (ML20086Q883)
- ML20086Q884 + (ML20086Q884)
- ML20086Q894 + (ML20086Q894)
- ML20086Q903 + (ML20086Q903)
- ML20086Q904 + (ML20086Q904)
- 05000280/LER-1975-004-01, /01T:on 750131,steam Generator C Narrow Range Level Channel 2 Indication Found Drifted 65%.Caused by Magnetic Sludge Deposits in Sensing Lines.Channel Placed in Trip Mode & Lines Blown Down + (ML20086Q906)
- ML20086Q914 + (ML20086Q914)
- ML20086Q917 + (ML20086Q917)
- ML20086Q918 + (ML20086Q918)
- ML20086Q923 + (ML20086Q923)
- ML20086Q925 + (ML20086Q925)
- ML20086Q928 + (ML20086Q928)
- ML20086Q929 + (ML20086Q929)
- ML20086Q932 + (ML20086Q932)
- ML20086Q933 + (ML20086Q933)
- ML20086Q939 + (ML20086Q939)
- ML20086Q947 + (ML20086Q947)
- ML20086Q949 + (ML20086Q949)
- ML20086Q957 + (ML20086Q957)
- ML20086Q959 + (ML20086Q959)
- ML20086Q967 + (ML20086Q967)
- ML20086Q969 + (ML20086Q969)
- ML20086Q972 + (ML20086Q972)
- ML20086Q980 + (ML20086Q980)
- 05000280/LER-1975-001-03, /03L:on 750218,pump 1-SW-P-6 Supplying Radiation Monitor RM-SW-107 Failed.Caused by Erosion.Sampling Initiated Until Design Mod Installed + (ML20086Q983)
- ML20086Q987 + (ML20086Q987)
- ML20086Q989 + (ML20086Q989)
- ML20086Q995 + (ML20086Q995)
- ML20086Q996 + (ML20086Q996)
- ML20086Q997 + (ML20086Q997)