- ML20081M294 + (ML20081M294)
- ML20081M304 + (ML20081M304)
- ML20081M308 + (ML20081M308)
- 1CAN108303, Monthly Operating Rept for Sept 1983 + (ML20081M316)
- ML20081M318 + (ML20081M318)
- ML20081M326 + (ML20081M326)
- ML20081M328 + (ML20081M328)
- ML20081M334 + (ML20081M334)
- ML20081M336 + (ML20081M336)
- ML20081M338 + (ML20081M338)
- ML20081M342 + (ML20081M342)
- 05000321/LER-1983-102-03, /03L-0:on 831011,standby Liquid Relief Valve C41-F029A Declared Inoprable.Caused by Valve Failure.All Internal Parts Cleaned,Reassembled W/New Gaskets & Reinstalled.Valve Adjusted & Returned to Svc + (ML20081M344)
- ML20081M346 + (ML20081M346)
- ML20081M357 + (ML20081M357)
- 05000387/LER-1983-143-03, /03L-0:on 830929,following Replacement of Common Inlet Filter for Reactor Bldg Zone III Refueling Floor Supply Fans,Fans Tripped After Starting.Caused by Low Flow Signals Due to Failure to Adjust Inlet Damper + (ML20081M361)
- ML20081M365 + (ML20081M365)
- 05000289/LER-1983-033-03, /03L-0:on 830928,reactor Bldg High Pressure Switch Setpoint on Reactor Protective Sys Channel a Found Less Conservative than Tech Spec Limit.Caused by Setpoint Drift. Switch Recalibr + (ML20081M367)
- ML20081M373 + (ML20081M373)
- ML20081M375 + (ML20081M375)
- 05000324/LER-1983-074-03, /03L-0:on 831006,reactor Recirculation Pump 2A Tripped Due to Motor Generator Set High Fluid Drive Temp. Caused by Slight Mechanical Shock of Motor Generator Set Fluid Drive High Temp Trip Device + (ML20081M380)
- 2CAN108308, Monthly Operating Rept for Sept 1983 + (ML20081M402)
- ML20081M417 + (ML20081M417)
- AECM-83-0717, RO 83-097/0:on 831003,auxiliary Bldg Steam Line Tunnel Temps Exceeded Tech Spec 3.7.8 Limit.Analysis to Demonstrate Continued Operability in Progress.Update Rept Expected by 831120 + (ML20081M419)
- ML20081M425 + (ML20081M425)
- ML20081M428 + (ML20081M428)
- ML20081M434 + (ML20081M434)
- 05000281/LER-1983-047-03, /03L-0:on 831005 & 23,w/unit at 100%,pump 2-RS-P-2A Tripped on Overload During Monthly Surveillance Tests,Contrary to Tech Spec 3.4.A.2.Caused by Instantaneous Trip Set Below Specs.Overload Setting Adjusted + (ML20081M436)
- BSEP-83-3540, RO 2-83-84:on 830930,determined Rod Worth Minimizer Inoperable Due to Sequencing Overlap.Further Evaluation Concluded Event Not Reportable.Deletion of LER 2-83-84 Requested + (ML20081M460)
- AECM-83-0699, RO 83-095/0:on 830926,fire-rated Assembly Penetrations AE53D & AE590D Discovered Open.Penetrations Not Listed on Schedule.Fire Watch Established Until Penetrations Sealed. Sealing Completion Expected by 831230 + (ML20081M462)
- 05000321/LER-1981-112-03, Torus to Rx Bldg Differential Pressure Switches 1T48-N210,N211,2T48-N210 & N211 Proof Press Not within Tech Spec Limit.Caused by Switch Misapplication.Also Reported Per Part 21 + (ML20081M464)
- ML20081M466 + (ML20081M466)
- ML20081M469 + (ML20081M469)
- ML20081M471 + (ML20081M471)
- 05000280/LER-1983-045-03, /03L-0:on 831010 & 17,core Cooling Monitor a Declared Inoperable Following Erratic Indication.Cause of 831010 Event Not Determined.Event on 831017 Caused by Bad Connector in Power Supply.Supply Replaced + (ML20081M473)
- PLA-1891, Monthly Operating Rept for Sept 1983 + (ML20081M477)
- ML20081M485 + (ML20081M485)
- 05000366/LER-1983-109-03, /03L-0:on 831019,drywell Vent & Purge Isolation Valve 2T48-F340 Gave Double Position Indication & Declared Inoperable.Caused by Unadjusted Closed Position Switch. Switch Adjusted + (ML20081M486)
- 05000328/LER-1983-146-03, /03L-0:on 831012,pressurizer Level Channels 2-LT-68-320 & 2-LT-68-335 Found Out of Calibr During Refueling Operations.Probably Caused by Instrument Drift. Transmitter Recalibr & Returned to Svc + (ML20081M490)
- ML20081M492 + (ML20081M492)
- NLS9100416, Rev to 910425 Application for Amend to License DPR-46, Consisting of Updated Tech Spec Page for Proposed Change 79 Re Reactor Water Level 3 Setpoint & Incorporates Changes to License Through Amend 142 Issued 910522 + (ML20081M499)
- 05000373/LER-1983-121-03, /03L-0:on 831014,while Performing LOS-AA-W1, Control Rod Drive at Core Location 30-19 Indicated Overtravel When Withdrawn to Full Out Position.Caused by Excessive Crud Buildup on Filter + (ML20081M502)
- ML20081M503 + (ML20081M503)
- 05000327/LER-1983-138-03, /03L-0:on 831013,containment Isolation Valve 1-FCV-43-64,steam Generator Blowdown Sample Isolation Valve,Discovered Leaking.Caused by Broken Bellows.Bellows & Bonnet Assembly Replaced + (ML20081M505)
- 05000328/LER-1983-133-03, /03L-0:on 831012,auxiliary Feedwater Pump Declared Inoperable Due to Failure of Automatic Control Valve 2-LCV-3-156 to Open on Demand.Caused by Incorrect Air Pressure Supply Regulator Setting + (ML20081M507)
- ML20081M508 + (ML20081M508)
- ML20081M509 + (ML20081M509)
- 05000369/LER-1983-093-03, /03L-0:on 830926,Fire Door 819A Found Attached to Door Frame by Top Hinge & Door Closer Mechanism Only.Caused by Damage to Threads of Screw Holes.Screw Holes Retopped & New Screws Installed + (ML20081M511)
- NLS9100418, Forwards Results of Independent Audit of Decommissioning Trust Fund for Yr Ending 901231,including Statement of Assets & Fund Balance,Statement of Changes in Fund Balance & Schedule of Investments + (ML20081M512)
- ML20081M513 + (ML20081M513)
- NLS9100405, Requests Extension Until 920131 to Complete Actions in Response to Generic Ltr 88-20 Re Individual Plant Exams for Severe Accident Vulnerability (10CFR50.54(f)) + (ML20081M514)
- 05000325/LER-1983-049-01, /01T-0:on 831021,testing Per IE Bulletin 83-02 Revealed Two Crack Indications in HAZ on Pipe Side of Weld B32-Recirc-28-A-14 & B32-Recirc-28-B-8.Caused by Intergranular Stress Corrosion Cracking + (ML20081M515)