- ML20081H045 + (ML20081H045)
- ML20081H050 + (ML20081H050)
- ML20081H052 + (ML20081H052)
- 3F0395-14, Forwards Rev 20 to QA Program + (ML20081H058)
- ML20081H059 + (ML20081H059)
- ML20081H062 + (ML20081H062)
- ML20081H067 + (ML20081H067)
- GO2-83-952, Final Deficiency Rept,Condition 277,re Dc Motor Starting Resistors on Class IE Dc Motors Used in Valve Operators & Pump Drives.Initially Reported on 830805.Complete Review of Dc Current Motor Performed Using Appropriate Vendor Info + (ML20081H068)
- ML20081H070 + (ML20081H070)
- ML20081H072 + (ML20081H072)
- ML20081H073 + (ML20081H073)
- RBG-16-285, Responds to Generic Ltr 83-28 Required Actions Based on Generic Implications of Salem ATWS Events. Current Plans & Schedules Submitted.Util Participating in BWR Owners Group Efforts Re Functional Testing of Reactor Protection Sys + (ML20081H075)
- RBG-16-245, Final Deficiency Rept DR-93 Re Interconnecting Piping Between Reactor Water Cleanup Hx.Condition Determined Not Reportable Under 10CFR50.55(e) + (ML20081H085)
- 05000316/LER-1983-098-03, /03L-0:on 831003,operator Recorded Wrong Data for Containment Particulate Activity.Caused by Operator Misreading Column Readings.Crt Display Edited to Reduce Operation Confusion + (ML20081H087)
- ML20081H088 + (ML20081H088)
- ML20081H096 + (ML20081H096)
- ML20081H102 + (ML20081H102)
- ML20081H103 + (ML20081H103)
- 05000302/LER-1995-003, :on 950217,correction of Errors Resulted in Peak Cladding Temp Above 2,200 F Limit.Caused by non- Conservative Design Assumptions Due to Vendor Personnel Error.Core Operating Limits Revised + (ML20081H107)
- ML20081H116 + (ML20081H116)
- ML20081H126 + (ML20081H126)
- ML20081H130 + (ML20081H130)
- ML20081H133 + (ML20081H133)
- ML20081H137 + (ML20081H137)
- ML20081H138 + (ML20081H138)
- ML20081H141 + (ML20081H141)
- RBG-16-248, Interim Deficiency Rept DR-122.Investigation Ongoing.Interim or Final Status Rept Will Be Provided by 831216 + (ML20081H154)
- ML20081H157 + (ML20081H157)
- ML20081H159 + (ML20081H159)
- ML20081H163 + (ML20081H163)
- 05000331/LER-1995-002, :on 950224,group 1 Primary Containment Isolation Occurred.Caused by Seat Leakage Past Rack Isolation Valves.Isolation Valves Will Be Replaced + (ML20081H168)
- ML20081H193 + (ML20081H193)
- ML20081H200 + (ML20081H200)
- 05000387/LER-1983-125-03, /03L-0:on 830903,average Drywell Air Temp Exceeded Tech Specs by 1 Degree.Cause Not Stated.Plant Startup & Heatup Procedures Revised + (ML20081H216)
- GO2-83-954, Final Deficiency Rept 275 Re Reactor Water Cleanup Sys Leak Detection.Initially Reported on 830727.Temp Elements Existing in Rooms R-509 & R-511 Not Requiring Leak Detection Relocated.Completion Expected Prior to Fuel Load + (ML20081H218)
- 05000346/LER-1983-053-03, /03L-0:on 830925,fuel Handling/Spent Fuel Pool Area Radiation Monitor RE8446 Found Deenergized.Cause Unknown.Readout Module Switch Found in Off Position + (ML20081H226)
- 05000220/LER-1983-030-01, /01T-0:on 831003,while Carbon Dioxide Fire Suppression Sys Out of Svc for Surveillance Testing, Continuous Fire Watch Changed to Unapproved Continuous Fire Patrol.Caused by Manpower Problem + (ML20081H238)
- ML20081H244 + (ML20081H244)
- ML20081H252 + (ML20081H252)
- ML20081H254 + (ML20081H254)
- ML20081H271 + (ML20081H271)
- ML20081H285 + (ML20081H285)
- 05000374/LER-1995-005-01, :on 950218,outboard MSIV Failed to Close When Switch Placed in Closed Position.Caused by Sticking of Solenoid Pilot Valve.Valves Replaced + (ML20081H298)
- ML20081H306 + (ML20081H306)
- 05000313/LER-1983-021-03, /03L-0:on 830909,during Surveillance Test on Reactor Bldg Fire Sprinkler Sys,Discovered Wiring Discrepancy.Caused by Erroneous Terminations Since Plant Const.Valve Wiring Terminated + (ML20081H309)
- 05000362/LER-1983-070-03, /03L-0:on 830923,control Element Assembly Calculator 1 Declared Inoperable When Control Element Assembly 15 Indicated Spurious Rod Movement.Caused by Failed Circuit Board + (ML20081H316)
- ML20081H333 + (ML20081H333)
- ML20081H347 + (ML20081H347)
- ML20081H353 + (ML20081H353)
- 05000267/LER-1983-034-03, /03L-0:on 830921,problems Experienced W/Diesel Generator Set 1A During Weekly Surveillance Test.Caused by Diesel Engine 1A Overheating Due to Failure of Cooling Water Temp Control Valve to Open.Generator Shut Down + (ML20081H365)
- ML20081H370 + (ML20081H370)