List of results
- ML20080P894 + (ML20080P894)
- ML20080P897 + (ML20080P897)
- ML20080P900 + (ML20080P900)
- ML20080P907 + (ML20080P907)
- ML20080P909 + (ML20080P909)
- ML20080P913 + (ML20080P913)
- ST-HL-AE-4999, Forwards Summary Description of Proposed Vehicle Control Measures & Results of Vehicle Bomb Comparison.Encl Withheld + (ML20080P914)
- 05000282/LER-1983-021-03, /03L-0:on 830830,during Surveillance Test MV-32035,cooling Water Header Isolation Valve B Failed to Close.Caused by Failure of GE Auxiliary Switch,Part CR105X100P.Switch Replaced + (ML20080P915)
- ML20080P918 + (ML20080P918)
- ML20080P921 + (ML20080P921)
- 05000237/LER-1983-063-03, /03L-0:on 830830,while Performing MSIV 1090 Closure Test Procedure DOS-250-1,double Indication Occurred on MSIV 2-203-1B When Test Button Released.Caused by Ground on Limit Switch 1B.Circuit Will Be Corrected + (ML20080P922)
- ML20080P924 + (ML20080P924)
- ML20080P926 + (ML20080P926)
- AECM-84-0103, Comprehensive Rept on Standby Diesel Generators - Significant Activities to Enhance & Verify Reliability + (ML20080P932)
- 05000373/LER-1983-105-01, /01T-0:on 830914,reactor Water Level Rapidly Decreased from 50 Inches to 0 Inches Causing Group VI PCIS Initiation at 12.5 Inches During Valve Lineup.Caused by Injection Check Valve Being Stuck Open + (ML20080P933)
- ML20080P934 + (ML20080P934)
- NG-95-0482, Requests That RM Herdegen & Jm Pladsen Tkae BWR Generic Fundamental Exam Section of Written Operator Licensing Exam + (ML20080P936)
- ML20080P937 + (ML20080P937)
- ML20080P942 + (ML20080P942)
- ML20080P945 + (ML20080P945)
- 05000361/LER-1983-113-03, /03L-0:on 830825,while in Mode 1,shiftly Surveillance on Control Element Assembly Calculator 2 Revealed That Three Auto Restarts Occurred within 12 H. Caused by Poorly Seated Disc Interface Card + (ML20080P946)
- ML20080P949 + (ML20080P949)
- ML20080P957 + (ML20080P957)
- ML20080P959 + (ML20080P959)
- ML20080P960 + (ML20080P960)
- ML20080P963 + (ML20080P963)
- ML20080P968 + (ML20080P968)
- 05000333/LER-1993-019-02, Forwards Updated CR Habitability Rept, Response to NUREG-0737,III.D.3.4 CR Habitability for JAFNPP, Per Commitment to Submit Rept as Corrective Action Associated W/ LER-93-019-02 + (ML20080P969)
- ML20080P976 + (ML20080P976)
- 05000361/LER-1983-114-03, /03L-0:on 830825,while in Mode 1,containment Isolation Valve 2HV-0512 Gave Dual Position Indication. Cause Unknown.Investigation Suspended Pending Containment Entry During Next Outage + (ML20080P977)
- ML20080P983 + (ML20080P983)
- ML20080P986 + (ML20080P986)
- 05000275/LER-1983-022-03, /03L-0:on 830831,valve MU-0-268 Shut for 36 Minutes,Isolating Raw Water Reservoir from Fire Suppression Header,Rendering Fire Suppression Water Sys Inoperable. Caused by Broken Underground Water Supply Line + (ML20080P988)
- ML20080Q001 + (ML20080Q001)
- ML20080Q002 + (ML20080Q002)
- 05000361/LER-1983-119-03, /03L-0:on 830828,Group 6 Control Element Assemblies (CEA) Inserted to Control Axial Shape Index. Reactor Coolant Cold Leg Temp Observed Below Limits.Caused by Effects of Xenon build-in & CEA Insertion + (ML20080Q018)
- ML20080Q020 + (ML20080Q020)
- ML20080Q027 + (ML20080Q027)
- ML20080Q032 + (ML20080Q032)
- 05000361/LER-1983-117-01, /01T-0:on 830905,pressurizer Level Instrument 2LI-0103A on Essential Plant Parameter Monitoring Sys Panel 2L-411 Varied from Correct Reading by Approx 15%.Level Correction Applied + (ML20080Q035)
- ML20080Q049 + (ML20080Q049)
- 05000254/LER-1983-032-03, /03L-0:on 830901,while Preparing for Refuel Outage,Secondary Containment Capability Test Revealed Vacuum Attainment of 0.15-inch Water.Caused by Aged Gaskets on Personnel Access Doors.Gaskets Replaced + (ML20080Q050)
- NG-95-0759, Application for Amend to License DPR-49,to Modify Pump & Valve Surveillance Criteria for LPCI & Core Spray Subsystems,Rhr Svc Water,Hpci,Esw & River Water Supply Systems + (ML20080Q061)
- 05000361/LER-1983-115-03, /03L-0:on 830829,toxic Gas Isolation Sys Train a Ammonia Analyzer Declared Inoperable.Failure Caused by Change in Amplifier Gain.Amplifier Board & Analyzer Recalibr + (ML20080Q062)
- 05000362/LER-1983-060-03, /03L-0:on 830830,control Element Assembly Calculator 1 & Core Protection Calculator Channel B Inoperable.Caused by Failed Input Amplifier Card.Card Replaced + (ML20080Q075)
- ML20080Q076 + (ML20080Q076)
- ML20080Q085 + (ML20080Q085)
- ML20080Q087 + (ML20080Q087)
- ML20080Q091 + (ML20080Q091)
- ML20080Q092 + (ML20080Q092)
- 05000362/LER-1983-066-03, /03L-0:on 830829 & 31,while in Mode 2,control Element Assembly Calculator 2 Experienced Excessive Auto Restarts.First Event Caused by Faulty Central Processing Unit Board.Cause for Second Event Unknown + (ML20080Q094)