- 05000416/LER-1982-134, Forwards LER 82-134/03L-0 + (ML20079J662)
- ML20079J666 + (ML20079J666)
- RBG-16-768, Interim Deficiency Rept DR-121 Re Motor Control Ctr Equipment Supplied by Ite Gould,Inc.Investigation Incomplete.Interim or Final Status Rept Will Be Provided by 840323 + (ML20079J668)
- 05000416/LER-1982-134-03, /03L-0:on 821201,during Cold Shutdown,Rhr Loop a Shut Down to Allow Flush of RHR Loop B Piping.Caused by Need to Maintain RHR Loop B for Return to Operation.Rhr Loop a Returned to Svc + (ML20079J671)
- AECM-84-0025, RO 83-113/0:on 831202,fire-rated Door 1A201 to Turbine Bldg Reported Inoperable.Caused by Damaged Latching Mechanism Due to Heavy Use.Door Restored on 831213 + (ML20079J674)
- 05000395/LER-1983-139-03, /03L-0:on 831214,remote Info Acquisition Cabinet 12 Tripped,Causing Intermediate Bldg Sprinkler Sys to Go Into Alarm Mode.Caused by Water Entering Panel & Shorting Out Electronic Cards.Cards Replaced + (ML20079J677)
- SNRC-1005, Forwards Field Test of Emergency Diesel Generator 101. Data Used by Failure Analysis Assoc in Investigation of Crankshaft Failure on Diesel Generator 102 + (ML20079J680)
- ML20079J682 + (ML20079J682)
- 05000416/LER-1982-048-99, /99X-0:on 820812,discovered Unsealed Fire Barrier Between Two Control Room Cabinets.Caused by Const Oversight. Fire Barrier Sealed by Maint Work Order on 820919 + (ML20079J685)
- ML20079J686 + (ML20079J686)
- ML20079J690 + (ML20079J690)
- ML20079J698 + (ML20079J698)
- ML20079J699 + (ML20079J699)
- ML20079J703 + (ML20079J703)
- 3F0184-03, Responds to NRC Re Violations Noted in IE Insp Rept 50-302/83-27.Corrective Actions:Rcs Leakage Determination Satisfactorily Completed & Automated Tracking Program for Control Rod 3 Initiated + (ML20079J704)
- ML20079J706 + (ML20079J706)
- ML20079J707 + (ML20079J707)
- PLA-1436, Final Deficiency Rept Re Nonconformance of Bechtel Field Welding.Initially Reported on 821115.Training Sessions Conducted Re Welding QC Requirements & Procedures FP-G-24 & FP-W-1 Will Be Revised.Also Reported Per Part 21 + (ML20079J708)
- ML20079J711 + (ML20079J711)
- ML20079J716 + (ML20079J716)
- ML20079J723 + (ML20079J723)
- ML20079J730 + (ML20079J730)
- TXX-3591, Responds to IE Bulletin 82-01,Revision 1,Suppl 1, Alteration of Radiographs of Welds in Piping Subassemblies. All But Six Welds Will Meet Applicable Code Requirements + (ML20079J732)
- ML20079J733 + (ML20079J733)
- ML20079J735 + (ML20079J735)
- ML20079J736 + (ML20079J736)
- ML20079J741 + (ML20079J741)
- ML20079J742 + (ML20079J742)
- ML20079J745 + (ML20079J745)
- ML20079J748 + (ML20079J748)
- ML20079J750 + (ML20079J750)
- ML20079J751 + (ML20079J751)
- ML20079J752 + (ML20079J752)
- DCL-84-011, Forwards Attachments A,B & C to Rev 11 to Security Plan. Attachments Withheld (Ref 10CFR73.21) + (ML20079J753)
- SNRC-1008, Forwards List of Active Safety-Related Equipment at Qualification Level, Per SER Issue 8, Dynamic Qualification & Util 821123 Commitment + (ML20079J756)
- ML20079J760 + (ML20079J760)
- PLA-1439, Interim Deficiency Rept Re Design Verification of Max Permissible Lengths of Wire in Low Voltage Power & Control Circuits.Caused by Bechtel Failure to Follow Procedures. Final Rept by 830415.Also Reportable Per Part 21 + (ML20079J762)
- ML20079J764 + (ML20079J764)
- 05000416/LER-1982-033-99, /99X-1:on 820814,HPCS Diesel Generator 13 Started on Low Reactor Vessel Level Indication & Tripped on Overspeed.Caused by Faulty Tachometer Relay.Dynalco Relay Replaced & Sys Restored on 820818 + (ML20079J767)
- ML20079J772 + (ML20079J772)
- ML20079J774 + (ML20079J774)
- ML20079J776 + (ML20079J776)
- 05000335/LER-1982-060, Forwards LER 82-060/03L-0 + (ML20079J778)
- ML20079J784 + (ML20079J784)
- ML20079J787 + (ML20079J787)
- ML20079J792 + (ML20079J792)
- 05000335/LER-1982-060-03, /03L-0:on 821117,during Full Power Operation, Auxiliary Feedwater Flow Recorder 1B & Sigma Indicated Flow When Actual Flow Zero.Caused by Defective Force Motor Internal to Transmitter.Transmitter Replaced + (ML20079J799)
- ML20079J806 + (ML20079J806)
- ML20079J811 + (ML20079J811)
- ML20079J812 + (ML20079J812)
- ML20079J825 + (ML20079J825)