- ML20077F527 + (ML20077F527)
- 05000254/LER-1991-012, :on 910507,HPCI Turbine Stop Valve Failed to Stroke Fully Open During Manual Initiation Test.Caused by Long Bushing in Stuffing Box of Stop Valve Sliding Down. Stuffing Boxes,Bushings & Pins Replaced + (ML20077F530)
- 05000277/LER-1991-012-01, :on 910514,discovered That Primary Containment Isolation Valve on Units TIP Sys Purge Lines Not Being Leak Tested.Caused by Inadequate Review of TIP Sys Purge Piping. Procedure Revised to Allow Testing Downstream + (ML20077F533)
- B15050, Provides Relief Requests Identified as R-24,R-33 & R-34.New Relief Request R-33 Provides for full-stroke Time Testing of Pressurizer Power Operated Relief Valves at Test Facility + (ML20077F537)
- ML20077F538 + (ML20077F538)
- 05000259/LER-1983-038-03, /03L-0:on 830627,trouble Alarm Came in for Control Bay Elevation 593 Fire Protection Panel 1-25-325,Zone 14,due to Power Loss to Some Smoke Detectors.Power Loss Caused by Loose Wire Connected to Detector XS-39-104BE + (ML20077F547)
- ML20077F561 + (ML20077F561)
- ML20077F563 + (ML20077F563)
- 05000244/LER-1983-025-03, /03L-0:on 830620,small Leak Found in 3/8-inch Diameter Swag Lock Compression Fitting Connection Upstream of Pressurizer Liquid Sample Manual Isolation Valve V-956E. Caused by Thermal Stress + (ML20077F569)
- ML20077F570 + (ML20077F570)
- ML20077F573 + (ML20077F573)
- 05000387/LER-1983-095-03, /03L-0:on 830624,during Performance of Monthly Channel Functional Test of HPCI Turbine Exhaust Diaphragm, Pressure Channel Isolation Signal Received.Meter Incorrectly Installed Across Terminals + (ML20077F575)
- ML20077F576 + (ML20077F576)
- ML20077F579 + (ML20077F579)
- ML20077F582 + (ML20077F582)
- ML20077F584 + (ML20077F584)
- ML20077F587 + (ML20077F587)
- ML20077F590 + (ML20077F590)
- ML20077F593 + (ML20077F593)
- ML20077F596 + (ML20077F596)
- 05000250/LER-1983-011-03, /03L-0:on 830624,malfunction of Fire Ionization Detector 3-10 Caused Inside Containment Fire Detection Zone 3 to Be Disabled for Longer than 14 Days.Root Cause Unknown. Repairs to Be Performed During Next Outage + (ML20077F602)
- ML20077F611 + (ML20077F611)
- ML20077F615 + (ML20077F615)
- ML20077F616 + (ML20077F616)
- ML20077F617 + (ML20077F617)
- 05000389/LER-1983-031-03, /03L-0:on 830624,hot Shutdown Control Panel Steam Generator a Narrow Range Level Indication Failed. Caused by Failure of Level Transmitter.Transmitter Replaced + (ML20077F618)
- ML20077F622 + (ML20077F622)
- ML20077F624 + (ML20077F624)
- ML20077F625 + (ML20077F625)
- ML20077F627 + (ML20077F627)
- ML20077F629 + (ML20077F629)
- ML20077F630 + (ML20077F630)
- ML20077F632 + (ML20077F632)
- ML20077F633 + (ML20077F633)
- 05000346/LER-1994-005, :on 941103,RPS Channel 4 Response Times Exceeded.Caused by Incorrect Buffer Amplifier Module Ordered from Warehouse.Correct Buffer Amplifier Installed + (ML20077F637)
- ML20077F638 + (ML20077F638)
- HL-1677, Forwards Util Response to SALP Repts 50-321/91-07 & 50-366/91-07 + (ML20077F643)
- ML20077F652 + (ML20077F652)
- ML20077F656 + (ML20077F656)
- ML20077F662 + (ML20077F662)
- ML20077F666 + (ML20077F666)
- 05000416/LER-1983-073-03, /03L-0:on 830623,review Revealed That 30 Closure Times for Scram Discharge Vol Vent & Drain Valves Not Verified on 820901.Caused by License Restrictions.Change to Tech Specs for 4.0.4 Applicability Requested + (ML20077F671)
- LIC-94-0236, Comment Supporting Proposed Rule 10CFR20 Re Frequency of Medical Exams for Use of Respiratory Protection Equipment. Util Feels Proposed Change Would Be Beneficial in Terms of Cost Savings + (ML20077F679)
- 05000416/LER-1983-021, Updated LER 83-021/01T-1:on 830519,determined That Standby Gas Treatment Sys Flow Monitoring Instrumentation Reading in Error.Caused by Incorrect Calibr Range Based on Postulated Instead of Std Conditions.Instruments Recalibr + (ML20077F683)
- RC-94-0292, Comment Supporting Proposed Rule 10CFR20 Re Frequency of Medical Exams for Use of Respiratory Protection Equipment. Util Agrees That Frequency of Medical Exams Should Be Determined by Physician + (ML20077F684)
- ML20077F686 + (ML20077F686)
- ML20077F688 + (ML20077F688)
- ML20077F691 + (ML20077F691)
- ML20077F694 + (ML20077F694)
- ML20077F695 + (ML20077F695)
- ML20077F697 + (ML20077F697)