- ML20076H983 + (ML20076H983)
- 05000369/LER-1983-029-03, /03L-0:on 830510 & 15,boron Concentration Dropped Below 1,900 Ppm in Cold Leg Injection Accumulator.Caused by Leakage Into Accumulator from RCS Through Check Valves 1NI70 & 1NI71.Valves Repaired + (ML20076H986)
- 05000370/LER-1983-008-03, /03L-0:on 830418,upper & Lower Personnel Airlocks Declared Inoperable When Blown & Ruptured Inner Seals, Respectively,Discovered on Auxiliary Bldg Door.Caused by Design Deficiency + (ML20076H989)
- ML20076H995 + (ML20076H995)
- 05000369/LER-1983-028-01, /01T-0:on 830525,impulse Lines for Two Redundant Steam Generator 1D Level Instruments Came within 2 Inches of Each Other at One Point.Caused by Const/Installation Deficiency.One Line Rerouted + (ML20076J006)
- ML20076J009 + (ML20076J009)
- ML20076J016 + (ML20076J016)
- LD-83-053, Forwards Basis for Design of Plant W/O Pipe Whip Restraints for RCS Main Loop Piping, to Demonstrate That guillotine-type Failure of RCS Main Loop Piping Need Not Be Considered in Design Basis for Sys 80 + (ML20076J018)
- ML20076J027 + (ML20076J027)
- 05000321/LER-1983-052-03, /03L-0:on 830506,alarms Received Indicating Trouble W/Diesel Generator Auxiliaries.Generator Untied & Tripped.Caused by Normal Supply Breaker Control Power Toggle Switch Being in Off Position.Position Adjusted + (ML20076J029)
- ML20076J032 + (ML20076J032)
- 05000369/LER-1983-032-03, /03L-0:on 830513,control Area Ventilation Sys Train a Failed to Meet Pressurization Criteria.Caused by Degradation of Door Seals & Lack of Trip Interlocks.Door Seals Taped & Later Replaced.Test Rerun + (ML20076J035)
- ML20076J038 + (ML20076J038)
- ML20076J042 + (ML20076J042)
- ML20076J044 + (ML20076J044)
- ML20076J048 + (ML20076J048)
- ML20076J051 + (ML20076J051)
- ML20076J053 + (ML20076J053)
- ML20076J055 + (ML20076J055)
- ML20076J064 + (ML20076J064)
- ML20076J066 + (ML20076J066)
- ML20076J073 + (ML20076J073)
- ML20076J076 + (ML20076J076)
- ML20076J079 + (ML20076J079)
- ML20076J085 + (ML20076J085)
- ML20076J094 + (ML20076J094)
- ML20076J095 + (ML20076J095)
- ML20076J102 + (ML20076J102)
- ML20076J108 + (ML20076J108)
- ML20076J109 + (ML20076J109)
- ML20076J120 + (ML20076J120)
- 05000348/LER-1983-022-03, /03L-0:on 830511,during Monthly Operability Check, Charging Pump 1C Declared Inoperable When Breaker DG06 Would Not Close.Caused by Broken follower-roller in Breaker Spring Charging Mechanism.Broken Part Replaced + (ML20076J124)
- ML20076J127 + (ML20076J127)
- ML20076J133 + (ML20076J133)
- ML20076J134 + (ML20076J134)
- ML20076J136 + (ML20076J136)
- ML20076J139 + (ML20076J139)
- IR 05000077/1983002 + (ML20076J144)
- ML20076J146 + (ML20076J146)
- JAFP-83-0561, Responds to NRC Re Violations Noted in IE Insp Rept 50-333/82-28.Corrective Actions:Work Procedure Revised to Include Insp & Hold Points as Appropriate,During Biennial Review of Procedure + (ML20076J149)
- ML20076J152 + (ML20076J152)
- ML20076J155 + (ML20076J155)
- NRC-94-4315, Forwards Errata to Proprietary AP600 Testing Program Rept, WCAP-14135,adding Listed Sentence to End of First Paragraph on Page 3-6.Errata Withheld.Also See 9809290284 + (ML20076J157)
- ML20076J158 + (ML20076J158)
- ML20076J160 + (ML20076J160)
- ML20076J161 + (ML20076J161)
- ML20076J164 + (ML20076J164)
- ML20076J166 + (ML20076J166)
- ML20076J169 + (ML20076J169)
- ML20076J172 + (ML20076J172)
- ML20076J174 + (ML20076J174)