- ML20073D898 + (ML20073D898)
- ML20073D907 + (ML20073D907)
- ML20073D909 + (ML20073D909)
- ML20073D910 + (ML20073D910)
- ML20073D911 + (ML20073D911)
- 05000260/LER-1991-005-01, :on 910327,unplanned ESF Actuation Occurred. Caused by Unexpected Failure of Relay Coil.Replacing Relay Coil & Realigning Affected Sys,Work Requests Issued & Replacing GE Type Relays + (ML20073D912)
- ML20073D914 + (ML20073D914)
- ML20073D915 + (ML20073D915)
- ML20073D920 + (ML20073D920)
- ML20073D922 + (ML20073D922)
- 05000374/LER-1991-003-06, :on 910328,reactor Bldg Ventilation Isolation Occurred.Caused by Personnel Error.Personnel Involved Tailgated Operating Crews on Importance of Procedural Adherence + (ML20073D932)
- JAFP-91-0228, Forwards Update of Status of Activities for Emergency Svc Water Sys Per NRC 901009 Request Re 900821 Enforcement Conference.Updated Response to Generic Ltr 89-13 Will Be Provided by 910430 + (ML20073D934)
- ML20073D935 + (ML20073D935)
- ML20073D939 + (ML20073D939)
- 05000298/LER-1991-003, :on 910325,unplanned Actuation of Group IV Isolation Occurred During Testing.Caused by Personnel Error & Procedure Deficiency.Procedure Change Being Processed Providing Improved Direction for Action + (ML20073D941)
- ML20073D942 + (ML20073D942)
- 05000458/LER-1991-005, :on 910322,design Deficiencies in Fire Doors. Discovered.Caused by Design Error.Hourly Fire Watch Established,Fire Doors Inspected & Surveillance Procedure STP-000-3001 Revised + (ML20073D943)
- ML20073D955 + (ML20073D955)
- ML20073D956 + (ML20073D956)
- 05000298/LER-1991-004, :on 910326,unplanned Automatic Startup of Diesel Generator 1 Occurred.Caused by Inadequate Planning & Poor Communications.Shutdown Cooling Restored & Sys Realigned Prior to Configuration + (ML20073D957)
- ML20073D965 + (ML20073D965)
- RBG-40873, Monthly Operating Rept for Aug 1994 for River Bend Station + (ML20073D969)
- ML20073D974 + (ML20073D974)
- ML20073D980 + (ML20073D980)
- GO2-83-178, Forwards Emergency Plan Implementing Procedures,W/Exception of EPIP 13.1.1, Classification of Emergency. EPIP 13.1.1 Will Be Submitted by 830315.W/o Encl + (ML20073D986)
- ML20073D991 + (ML20073D991)
- ML20073D998 + (ML20073D998)
- ML20073E004 + (ML20073E004)
- ML20073E005 + (ML20073E005)
- HL-1586, Responds to NRC Re Violations Noted in Insp Repts 50-321/91-04 & 50-366/91-04.Corrective Actions:Design Change Request 2H91-023 Implemented to Raise Condensate Storage Tank Level Switch Setpoints Approx 22 1/2 Inches + (ML20073E008)
- NLS9100264, Forwards Scope & Objectives for 1991 Emergency Preparedness Exercise Scheduled for 910724-25 + (ML20073E010)
- ML20073E012 + (ML20073E012)
- NPL-94-0354, Provides Listed Info in Response to RAI Re Anchorage Design for Pbnp DG Addition Project + (ML20073E015)
- 05000373/LER-1991-002-08, :on 910326,Div 1,Group 4 Primary Containment Isolation Occurred,Causing Reactor Bldg Ventilation Inboard Dampers to Close.Caused by Loosening Electrical Connection. Temporary Sys Change Procedure Revised + (ML20073E020)
- 05000361/LER-1983-028-01, /01T-0:on 830323,potential Safety Concern Identified,Involving Calibr Shift of Foxboro 2AO-V31 Modules Associated W/Core Protection Calculators.Caused by Problems W/Amplifier.Design Change Approved to Replace Modules + (ML20073E029)
- ML20073E037 + (ML20073E037)
- 05000361/LER-1983-031-01, /01T-0:on 830323,potential Safety Concern Identified,Involving Calibr Shift of 2AO-V31 Modules Associated W/Core Protection Calculators.Caused by Problems W/Amplifier.Design Change Initiated to Replace Modules + (ML20073E049)
- LIC-94-0186, Forwards Fort Calhoun Station Performance Indicators + (ML20073E050)
- ML20073E051 + (ML20073E051)
- BSEP-91-0177, Special Rept 1-SR-91-001:on 910326,limiting Conditions for Operation Initiated Due to Inoperable Fire Doors.Caused by Routine Usage.Fire Doors 207,107 & 214 Repaired & Restored on 910402.Station Fire Watches Were Maintained + (ML20073E052)
- 05000361/LER-1983-025, Forwards LER 83-025/03L-0.Detailed Event Analysis Submitted + (ML20073E057)
- ML20073E068 + (ML20073E068)
- ML20073E072 + (ML20073E072)
- 05000361/LER-1983-025-03, /03L-0:telephone Rept Made Re Failure of Reactor Trip Circuit Breakers to Trip on Undervoltage.Caused by Inadequacies in Certain Maint Activities.Return to Power Rept Scheduled for Submittal by Apr 1983 + (ML20073E073)
- ML20073E083 + (ML20073E083)
- ML20073E087 + (ML20073E087)
- ML20073E088 + (ML20073E088)
- ML20073E089 + (ML20073E089)
- ML20073E094 + (ML20073E094)
- ML20073E100 + (ML20073E100)
- ML20073E101 + (ML20073E101)