Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20069G905 + (ML20069G905)
- 05000317/LER-1980-041-01, 5 Minutes After Svc,Water Head Tanks Went from Normal Operating Level to Full,Isophase Bus Duct Cooling Low Flow Alarm Received.Caused by Air Compressor Failure Due to Cracked After Cooler Tubes + (ML20069G909)
- NG-94-0794, Request for TS (RTS-246A) Rev to RTS-246 to License DPR-49, Revising TS Section 3.7, Containment Sys + (ML20069G911)
- ML20069G912 + (ML20069G912)
- ML20069G914 + (ML20069G914)
- ML20069G918 + (ML20069G918)
- ML20069G919 + (ML20069G919)
- ML20069G921 + (ML20069G921)
- ML20069G923 + (ML20069G923)
- ML20069G925 + (ML20069G925)
- 05000361/LER-1982-116-03, /03L-0:on 820917,condensate Storage Tank T-120 Water Level Fell Below Tech Spec Limit.Caused by Inadequate Makeup Water Control to Tank T-121 & Overly Restrictive Tech Spec Limit.Design & Tech Spec Change Proposed + (ML20069G929)
- ML20069G930 + (ML20069G930)
- ML20069G932 + (ML20069G932)
- ML20069G934 + (ML20069G934)
- ML20069G935 + (ML20069G935)
- 05000361/LER-1982-117-03, /03L-0:on 820918,condensate Storage Tank T-120 Water Level Fell Below Tech Spec Limit.Caused by Inadequate Makeup Water Control to Tank T-121 & Overly Restrictive Tech Spec Limit.Design & Tech Spec Change Proposed + (ML20069G937)
- ML20069G940 + (ML20069G940)
- ML20069G941 + (ML20069G941)
- 05000361/LER-1982-112-03, /03L-0:on 820910,condensate Storage Tank T-120 Water Level Fell Below Tech Spec Limit.Caused by Inadequate Makeup Water Control to Tank T-121 & Overly Restrictive Tech Spec Limit.Design & Tech Spec Change Proposed + (ML20069G944)
- 05000368/LER-1983-009, Forwards LER 83-009/01T-0 + (ML20069G946)
- 05000338/LER-1982-061, Forwards LER 82-061/03L-0 + (ML20069G951)
- ML20069G953 + (ML20069G953)
- ML20069G954 + (ML20069G954)
- ML20069G958 + (ML20069G958)
- ML20069G961 + (ML20069G961)
- ML20069G963 + (ML20069G963)
- ML20069G964 + (ML20069G964)
- ML20069G965 + (ML20069G965)
- 05000338/LER-1982-061-03, /03L-0:on 820917,during Chemistry Log Review, Specific Activity of Primary Coolant Exceeded Tech Specs. Caused by Migration of I-131 Through Pinhole Leaks in Fuel Cladding.Specific Activity Returned to Acceptable Limits + (ML20069G975)
- ML20069G976 + (ML20069G976)
- 05000315/LER-1982-084, Forwards LER 82-084/04L-0 + (ML20069G981)
- 05000315/LER-1982-084-04, /04L-0:on 820912,unplanned Gas Release Detected by Elevated Vent Stack Gaseous Monitor.Caused by Leak on Waste Gas Oxygen Analyzer.Leak Repaired + (ML20069G991)
- 05000373/LER-1982-103, Forwards LER 82-103/03L-0 + (ML20069H000)
- ML20069H002 + (ML20069H002)
- ML20069H005 + (ML20069H005)
- 05000373/LER-1982-103-03, /03L-0:on 820919,Hi Rad Alarm Sounded.Operator Checked Chart Recorder & Noticed a RHR Svc Water Radiation Monitor Read Downscale.Alarm Caused by Trip in Power Supply to Monitor.Power Supply Reset + (ML20069H007)
- ML20069H013 + (ML20069H013)
- ML20069H019 + (ML20069H019)
- ML20069H023 + (ML20069H023)
- ML20069H025 + (ML20069H025)
- ML20069H027 + (ML20069H027)
- RBG-14-482, Suppls 811002 Response to IE Bulletin 80-16, Potential Misapplication of Rosemount,Inc Models 1151 & 1152 Pressure Transmitters W/Either a or D Output Codes. Final Rept to Be Submitted 830503,subj to GE Evaluation Completion + (ML20069H029)
- ML20069H030 + (ML20069H030)
- ML20069H031 + (ML20069H031)
- 05000305/LER-1982-029-01, /01X-1:on 820927,discovered That Monthly Testing Requirements Exceeded for Containment Radiation Monitors R-11 & R-12.Caused by Postponement of Test Due to Backup Radiation Monitor Being Out of Svc & Personnel Oversight + (ML20069H034)
- 05000305/LER-1982-031-03, /03L-0:on 820913,train 1B of Shield Bldg Vent Failed to Switch to Recirculation Mode After Drawing Vacuum. Recirculation Damper Failed to Open Due to Broken Hydraulic Pump on electro-hydraulic Damper Actuator.Operator Replac + (ML20069H036)
- ML20069H038 + (ML20069H038)
- ML20069H039 + (ML20069H039)
- ML20069H040 + (ML20069H040)
- 05000346/LER-1979-076, Forwards Revised LER 79-076/03X-1 + (ML20069H042)
- ML20069H043 + (ML20069H043)