- TXX-3567, Deficiency Rept Re Defective Governor Drive Coupling on Diesel Generators.Initially Reported on 820912.Drive Coupling Elements Will Be Replaced W/Neoprene Since Isoprene Rapidly Deteriorates & Ultimately Fails + (ML20063M758)
- ML20063M759 + (ML20063M759)
- PLA-1273, Final Deficiency Rept Re Incorrect Wipe Setting of Normally Closed Contacts on Hfa Relays.Initially Reported on 820813. All safety-related Hfa Relays for Unit 2 Checked & Recalibr. Also Reported Per Part 21 + (ML20063M760)
- ML20063M761 + (ML20063M761)
- ML20063M764 + (ML20063M764)
- 05000369/LER-1982-061, Forwards LER 82-061/03L-0.Detailed Event Analysis Encl + (ML20063M767)
- ML20063M770 + (ML20063M770)
- 05000338/LER-1982-055, Forwards LER 82-055/03L-0 + (ML20063M771)
- 05000369/LER-1982-061-03, /03L-0:on 820728,door on Reactor Bldg Side of Lower Containment Personnel Airlock Would Not Close.Caused by Disconnected Section of Tubing in Hydraulics Sys.Tubing Reinstalled W/New Fitting & Fluid Added + (ML20063M773)
- 05000324/LER-1982-104, Forwards LER 82-104/03L-0 + (ML20063M777)
- 05000338/LER-1982-055-03, /03L-0:on 820809,util Notified by Westinghouse That Potential Exists for Undetected Failure in Spss Resulting in No Safeguard Actuation from Affected Slave Relays.Surveillance Test Changed to Verify Closure + (ML20063M779)
- 05000317/LER-1982-050, Corrected Ltr Forwarding LER 82-050/03L-0 + (ML20063M780)
- 05000317/LER-1982-050-03, /03L-0:on 820805,17,21,22 & 23,pressure Level Deviated from Program Level During Startup & Shutdown Operations.Rcs Temp Swings by 10 Degrees Not Uncommon. Reanalysis for Relaxation of Tech Spec in Progress + (ML20063M781)
- 05000324/LER-1982-104-03, /03L-0:on 820811,determined That Required Verification of Indicated Power Availability for Specified Plant Dc/Ac Electrical Sys & offsite-onsite Class IE Electrical Sys Was Not Covered in Plant Procedures + (ML20063M782)
- 05000259/LER-1982-058, Forwards LER 82-058/03L-0 + (ML20063M783)
- 05000251/LER-1982-011, Forwards LER 82-011/03L-0 + (ML20063M785)
- 05000259/LER-1982-058-03, /03L-0:on 820810,elevation 620 MSL Wind Direction Recorder (1-XR-90-102-2) Read Downscale.Caused by Lightning Striking Near Environ Tower.Blown Fuses Replaced + (ML20063M787)
- AECM-82-362, Suppl to Final Deficiency Rept Re Error in Calculations for Impingement Loads on Targets During High Energy Pipe Line Breaks.Initially Reported on 820521.Addl Target Area Identified.Also Reported Per Part 21 + (ML20063M788)
- ML20063M789 + (ML20063M789)
- ML20063M792 + (ML20063M792)
- ML20063M793 + (ML20063M793)
- 05000251/LER-1982-011-03, /03L:on 820805,low Pressure Alarm (Set at 625 Psig) Received on 4B Accumulator.When Supply & Fill Valves Opened,Accumulator Pressure Dropped to 460 Psig. Caused by Loose Setting on Control Potentiometer + (ML20063M794)
- ML20063M797 + (ML20063M797)
- ML20063M799 + (ML20063M799)
- ML20063M800 + (ML20063M800)
- ML20063M804 + (ML20063M804)
- 05000366/LER-1982-087, Forwards LER 82-087/03L-0 + (ML20063M808)
- ML20063M810 + (ML20063M810)
- ML20063M811 + (ML20063M811)
- 05000366/LER-1982-087-03, /03L-0:on 820805,HPCI Steamline Differential Pressure Instrument Actuated at Setpoint Exceeding Tech Spec Limit.Caused by Setpoint Drift.Instrument Calibr & Tested Satisfactorily + (ML20063M812)
- ML20063M814 + (ML20063M814)
- 05000321/LER-1982-070, Forwards LER 82-070/03L-0 + (ML20063M816)
- 05000369/LER-1982-062, Forwards LER 82-062/03L-0 + (ML20063M819)
- ML20063M821 + (ML20063M821)
- 05000369/LER-1982-062-03, /03L-0:on 820801,RCS Nc Leakage Calculation Initiated,Revealing Unidentified Leakage of Approx 4.5 Gpm. Caused by Coolant Passing Through Chemical & Vol Control Sys Valve Packing.Valve Backseated + (ML20063M823)
- 05000277/LER-1982-020-03, /03L-0:on 820806,drywell Pressure Recorders PR-2508A & PR-2508B Failed Downscale Due to Blown Fuses. Caused by Intentional Ground on Positive Side of Transmitters.Mod to Eliminate Ground Completed on 820811 + (ML20063M826)
- ML20063M827 + (ML20063M827)
- 05000318/LER-1982-039, Forwards LER 82-039/01T-0 + (ML20063M836)
- 05000416/LER-1982-046, Forwards LER 82-046/03L-0 + (ML20063M838)
- 05000318/LER-1982-039-01, /01T-0:on 820824,employee Opened Inner Emergency Air Lock Door When Outer Door Not Secured.Release Calculated at 4.83E-8MR.Caused by Possible Misadjustment of Swing Actuating Rods + (ML20063M840)
- 05000247/LER-1982-033, Forwards LER 82-033/99X-0 + (ML20063M842)
- ML20063M845 + (ML20063M845)
- 05000416/LER-1982-046-03, /03L-0:on 820810,daily Fire Door Checks Discovered Not Conducted on 820617 & 24.Caused by Incomplete Communication Between Operating Shifts.Personnel Awareness Increased + (ML20063M846)
- 05000247/LER-1982-033-99, /99X-0:on 820819,svc Water Tube Leak Identified in Main Cooling Coil of Fan Cooler Unit 21.Coil 8 Found Leaking & Tube Bundle Isolated W/O Heat Transfer Capability, Thus Falling Below FSAR Assumption + (ML20063M849)
- AECM-82-394, Final Deficiency Rept Re Unsuitable Governor Drive Coupling on Transamerica Delaval Diesel Generators.Initially Reported on 820824.Flexible Isoprene Elements to Be Replaced W/ Neoprene Elements.Also Reportable Per Part 21 for Unit 1 + (ML20063M851)
- 05000416/LER-1982-045, Forwards LER 82-045/01T-0 + (ML20063M854)
- 05000321/LER-1982-076, Forwards LER 82-076/03L-0 + (ML20063M856)
- 05000321/LER-1982-076-03, /03L-0:on 820806,while in Steady State Operation W/Routine Calibr in Progress,Two Relative Humidity Controllers Found Inoperable on B Standby Gas Treatment Filter Train.Caused by Component Failure Due to Corrosion + (ML20063M858)
- 05000311/LER-1982-084-01, /01T-0:on 820829,discovered Svc Water Leak of 0.5 Gpm on Containment Fan Coil Unit 23.Caused by Erosion of Copper Nickel Cooling Coils.Coil Repaired W/Belzona + (ML20063M859)
- 05000321/LER-1982-069, Forwards LER 82-069/03L-0 + (ML20063M860)
- 05000416/LER-1982-045-01, /01T-0:on 820826,temporary Loss of Power Caused Reactor Scram.Caused by Tree Cutting Maint Near 500 Kv Transmission Line When Worker Felled Tree Across Line.Worker Consequently Killed.Power Restored & Scram Reset + (ML20063M862)