THE CINCINNATI GAS & ELECTRIC COMPANY cII CINCIN N ATI. OHIO 452OI August 20, 1982 QA-1950 E. A. BORG M AN N sa n.vm vict Fat set hf U. S. Nuclear Regulatory Commission Region III 799 Roosevelt Road Glen Ellyn, Illinois 60137 Attention:
Mr. J. G. Keppler Regional Administrator RE:
WM.11. ZIMMEP, NUCLEAR POWER STATION UNIT I 10CFR50.55(e) - ITEM M ANCHOR DARLING VALVE ANTIROTATIONAL COLI.AR SET SCREWS -
DOCKET No. 50-358, CONSTRUCTION PERMIT NO.
CPPR-88, W.O. #57300 JOB E-5590 FILE NO.
NRC-8, ITEM M-42 Gentlemen:
This letter constitutes a final report concerning the subject condition initially reported to the Commission under the requirements of 10CFR50.55(e).
As stated in our previous report,,A-1855, dated July 8, 1982, CG6E Nonconformance Report (NR) //0-NPD-82-2140-E was generated which noted that motor aperated Anchor-Darling valves with anti-rotational devices were subject to operational failure if the set screw holding the stem collar in place should lossen.
The CG6E Nuclear Production Department has dispositioned the afotementioned NR to stake the set screws of all safety related motor operated Anchor Darling valves with anti-rotational devices. All necessary work will be accomplished by December 31, 1982.
We trust the above will be found acceptable as a final report under 10CFR50.55(e).
Very truly yours, THE CINCINNATI CAS & ELECTRIC COMPANY By E. A. BORGMANN 8209160179 820820 PDR ADOCK 05000358 SENIOR VICE PRESIDENT S
PDR FKP:as cc: NRC Office of Inspection & Enforcement Washington, D.C.
20555 NRC Senior Resident Inspector
[
Attn:
W. F. Christianson Zimmer Project Inspector Agg 27 19g7 Region III