- 05000287/LER-1982-008-01, /01T-0:on 820609,during Removal of Locking Clips on Thermal Shield bolts,19 of 27 Bolts Had Bolt Heads Broken Off.Upon Completion of Locking Clip removal,46 of 96 Had Heads Broken Off.Caused by Stress Cracking + (ML20054L899)
- ML20054L900 + (ML20054L900)
- ML20054L901 + (ML20054L901)
- ML20054L903 + (ML20054L903)
- ML20054L904 + (ML20054L904)
- ML20054L905 + (ML20054L905)
- ML20054L906 + (ML20054L906)
- ML20054L907 + (ML20054L907)
- ML20054L909 + (ML20054L909)
- ML20054L910 + (ML20054L910)
- ML20054L911 + (ML20054L911)
- ML20054L912 + (ML20054L912)
- 05000327/LER-1982-068, Forwards LER 82-068/03L-0 + (ML20054L914)
- ML20054L916 + (ML20054L916)
- ML20054L917 + (ML20054L917)
- ML20054L919 + (ML20054L919)
- ML20054L920 + (ML20054L920)
- 05000369/LER-1982-040, Forwards LER 82-040/03L-0 + (ML20054L921)
- ML20054L923 + (ML20054L923)
- ML20054L925 + (ML20054L925)
- 05000327/LER-1982-068-03, /03L-0:on 820603,condenser Vacuum Exhaust Radiation Monitor 1-RM-90-119 Had Spurious High Radiation Signals.Caused by Noise Picked Up by Monitor Detector Signal Cable.Detector Cables Will Be Installed in Conduit + (ML20054L926)
- ML20054L927 + (ML20054L927)
- ML20054L928 + (ML20054L928)
- ML20054L929 + (ML20054L929)
- ML20054L930 + (ML20054L930)
- 05000369/LER-1982-037-03, /03L-0:on 820513,while in Mode 1,performance of Nuclear Air Cleaning Sys Air Flow Measurement Periodic Test Revealed That Train a of Annulus Ventilation Sys Failed to Meet Flow Acceptance Criteria.Caused by Component Failure + (ML20054L931)
- 05000369/LER-1982-040-03, /03L-0:on 820529,during Fire Protection Sys High Velocity Flush & Chlorination Periodic Test,Five Fire Hose Stations in Auxiliary Bldg Discovered W/O Adequate Water Pressure.Caused by Mistaken Valve Lineup in Test + (ML20054L932)
- ML20054L933 + (ML20054L933)
- W3P82-1518, Forwards Containment Purge Study,Providing Justification for Unlimited Purging During Normal Operation,Per SRP 6.2.4, Revision 1 & Associated Branch Technical Position Csb 6-4. NUREG-0737,Item II.E.4.2 Implemented,Per Util + (ML20054L935)
- ML20054L937 + (ML20054L937)
- ML20054L938 + (ML20054L938)
- ML20054L939 + (ML20054L939)
- ML20054L940 + (ML20054L940)
- ML20054L941 + (ML20054L941)
- ML20054L942 + (ML20054L942)
- ML20054L943 + (ML20054L943)
- ML20054L944 + (ML20054L944)
- ML20054L945 + (ML20054L945)
- ML20054L946 + (ML20054L946)
- 05000369/LER-1982-041-03, /03L-0:on 820513,HEPA & Carbon Absorber Filters Periodic Test Revealed That Carbon Absorber Filter on Train a of Annulus Ventilation Sys Failed to Pass Halogenated Hydrocarbon Penetration Test.Caused by Dirt in Filter + (ML20054L947)
- 05000325/LER-1982-056, Forwards LER 82-056/03L-0 + (ML20054L948)
- ML20054L950 + (ML20054L950)
- ML20054L952 + (ML20054L952)
- ML20054L953 + (ML20054L953)
- ML20054L954 + (ML20054L954)
- ML20054L955 + (ML20054L955)
- 05000321/LER-1982-052, Forwards LER 82-052/03L-0 + (ML20054L956)
- ML20054L959 + (ML20054L959)