- ML20054D104 + (ML20054D104)
- ML20054D106 + (ML20054D106)
- ML20054D107 + (ML20054D107)
- ML20054D108 + (ML20054D108)
- 05000316/LER-1982-021, Forwards LER 82-021/03L-0 + (ML20054D109)
- ML20054D111 + (ML20054D111)
- IR 05000483/1982001 + (ML20054D113)
- 05000133/LER-1982-003, Forwards LER 82-003/03L-0 + (ML20054D115)
- 05000316/LER-1982-021-03, /03L-0:on 820315,while in Mode 5,surveillance Testing of ESF Ventilation Sys Filter Train (HV-AES-2) Revealed One HEPA Filter Did Not Meet Air Flow Distribution Criteria.New Filters Installed + (ML20054D117)
- ML20054D119 + (ML20054D119)
- ML20054D121 + (ML20054D121)
- ML20054D122 + (ML20054D122)
- 05000311/LER-1982-021, Forwards LER 82-021/03L-0.Detailed Event Analysis Encl + (ML20054D123)
- ML20054D125 + (ML20054D125)
- IR 05000461/1981024 + (ML20054D126)
- ML20054D128 + (ML20054D128)
- AECM-82-158, Forwards Addl Info Re Independency of Cygna Energy Svcs & Bechtel.No Vested Interest in Design Control Scheme for Reactor Facility Determined + (ML20054D130)
- 05000133/LER-1982-003-03, /03L-0:on 820319,w/unit Shutdown,Ground Detected at Fire Pump 3 Motor.Caused by Defective Stator Due to Age & Deterioration.Stator Rewound.Preventive Maint Schedule Will Be Established + (ML20054D131)
- 05000311/LER-1982-021-03, /03L-0:on 820320,while Performing Surveillance Procedure SP(O)4.6.1.3 on 100 Ft Elevation Containment Air Lock,Leakage Rate Exceeded Limit of 0.05 La at Design Pressure of 47.0 Psig.Caused by Loose Chain on Inner Door + (ML20054D132)
- IR 05000346/1982003 + (ML20054D134)
- 05000309/LER-1982-014, Forwards LER 82-014/03L-0 + (ML20054D135)
- 05000272/LER-1981-120, Forwards LER 81-120/03X-1.Detailed Event Analysis Encl + (ML20054D137)
- ML20054D139 + (ML20054D139)
- ML20054D143 + (ML20054D143)
- ML20054D144 + (ML20054D144)
- ML20054D145 + (ML20054D145)
- ML20054D146 + (ML20054D146)
- 05000272/LER-1982-011, Forwards LER 82-011/03X-1.Detailed Event Analysis Encl + (ML20054D147)
- ML20054D149 + (ML20054D149)
- AECM-82-173, Forwards Addl Info Requested by Equipment Qualification Branch Re Justification for Interim Operation for Equipment Not Qualified to Seismic Qualification Review Team Criteria + (ML20054D150)
- ML20054D151 + (ML20054D151)
- 05000309/LER-1982-014-03, /03L-0:on 820326,during Start of Plant Heatup, Station Technical Advisor Was Not at Required Station for Period of 7-h.Caused by Misconception on Part of Assigned Personnel.Station Technical Assistants Advised of Procedure + (ML20054D156)
- ML20054D157 + (ML20054D157)
- 05000315/LER-1982-017, Forwards LER 82-017/03L-0 + (ML20054D159)
- 05000266/LER-1982-007-01, /01T-0:on 820329,during secondary-to-primary Leak Check,Two Leaking Tubes in a Steam Generator & 28 Defective Tubes in a & B Steam Generators Discovered.Caused by Caustic.All Defective & Leaking Tubes Plugged + (ML20054D161)
- ML20054D162 + (ML20054D162)
- 05000155/LER-1982-013, Forwards LER 82-013/01T-0 + (ML20054D163)
- ML20054D165 + (ML20054D165)
- 05000155/LER-1982-013-01, /01T-0:on 820328,during Drainage of Primary Sys Water Level,Steam Drum Level Indication Failed to Register Proper Water Level.Caused by Inadequate Procedure Re Filling Level Transmitter Ref Lines.Procedures Will Be Revised + (ML20054D166)
- 05000315/LER-1982-017-03, /03L-0:on 820320,during Normal Operation,Number 4 S/G Stop Valve Dump valves,MRV-241 & MRV-242 Removed from Svc to Repair Seat Leakage.Stem Disc,Seat Ring & Gaskets Replaced in Each Fisher Style 657 EAS Valve + (ML20054D167)
- 05000237/LER-1982-009, Forwards LER 82-009/03L-0 + (ML20054D168)
- 05000289/LER-1982-002, Forwards LER 82-002/03L-0 + (ML20054D170)
- ML20054D172 + (ML20054D172)
- 05000237/LER-1982-009-03, /03L-0:on 820317,refuel Floor Hi Rad Surveillance B SBGTS Failed.A SBGTS Did Not Start Upon Failure of B. Caused by Blown Gasket on Foxboro Controller,Model 130M. a SBGTS Failure Due to Short Initiation Signal + (ML20054D174)
- ML20054D175 + (ML20054D175)
- ML20054D178 + (ML20054D178)
- ML20054D179 + (ML20054D179)
- ML20054D180 + (ML20054D180)
- ML20054D181 + (ML20054D181)
- A02302, Comments on Draft Evaluation of SEP Topic VI-7.A.3, ECCS Actuation Sys + (ML20054D182)
- ML20054D183 + (ML20054D183)