- 05000499/LER-1993-007-01, :on 930310,determined That Control Room Envelope HVAC Sys Was Not in Mode of Operation Required by TS 3.7.7a & 3.3.3.7b.Caused by Implementation & Use of Computer Program.Review Will Be Performed + (ML20035D452)
- 05000424/LER-1993-003, :on 930316,light 431D,indicating over-temp Delta Temp Turbine Runback Bistable,Lit.Caused by Inadequate Review of Affected Circuitry Prior to Removing Circuit Card.Technicians Counseled + (ML20035D454)
- ML20035D456 + (ML20035D456)
- ML20035D457 + (ML20035D457)
- ML20035D460 + (ML20035D460)
- HL-3239, Monthly Operating Repts for March 1993 for Ei Hatch Nuclear Plant,Units 1 & 2 + (ML20035D462)
- HL-3248, Advises That Through Wall Leak Identified in Reactor Pressure Vessel N11B Instrument Nozzle safe-end.Flaw Removed & Replacement Pipe & Fittings Installed.Proposes to Perform Listed post-repair Hydrostatic Tests + (ML20035D463)
- ML20035D470 + (ML20035D470)
- ML20035D472 + (ML20035D472)
- ML20035D475 + (ML20035D475)
- ML20035D476 + (ML20035D476)
- ML20035D477 + (ML20035D477)
- ML20035D479 + (ML20035D479)
- ML20035D480 + (ML20035D480)
- ML20035D481 + (ML20035D481)
- ML20035D483 + (ML20035D483)
- ML20035D484 + (ML20035D484)
- ML20035D486 + (ML20035D486)
- ML20035D488 + (ML20035D488)
- ML20035D491 + (ML20035D491)
- ML20035D493 + (ML20035D493)
- ML20035D494 + (ML20035D494)
- ML20035D495 + (ML20035D495)
- ML20035D497 + (ML20035D497)
- ML20035D498 + (ML20035D498)
- BSEP-93-0050, Monthly Operating Repts for Mar 1993 for Brunswick Steam Electric Plant,Units 1 & 2 + (ML20035D501)
- ML20035D502 + (ML20035D502)
- ML20035D504 + (ML20035D504)
- ML20035D505 + (ML20035D505)
- ML20035D506 + (ML20035D506)
- ML20035D511 + (ML20035D511)
- ML20035D520 + (ML20035D520)
- ML20035D526 + (ML20035D526)
- ML20035D532 + (ML20035D532)
- ML20035D538 + (ML20035D538)
- ML20035D542 + (ML20035D542)
- ML20035D548 + (ML20035D548)
- ML20035D555 + (ML20035D555)
- ML20035D560 + (ML20035D560)
- ML20035D566 + (ML20035D566)
- ML20035D572 + (ML20035D572)
- ML20035D576 + (ML20035D576)
- ST-HL-AE-4406, Forwards Revised Ltrs ST-HL-AE-4395 & ST-HL-AE-4396 Sent to NRC W/Isi Summary Rept for Sys Pressure Tests & ISI Summary Rept for Repairs & Replacements on 930331.Revised Ltrs Reflect Correct Docket 50-498 + (ML20035D584)
- 05000309/LER-1993-004, :on 930308,upper Level Spray Pump Bldg Fire Door Became Inoperable Due to Personnel Error.Heating Ventilation Unit HV-7 Returned to Svc.Precautions Will Be Placed in Ventilation Procedures + (ML20035D589)
- ST-HL-AE-4395, Corrected Ltr Transmitting Unit 1 Fourth Refueling Outage (1REO4) ISI Summary Rept for Sys Pressure Tests Performed Under ASME Code,Section Xi.W/O Encl + (ML20035D592)
- ST-HL-AE-4396, Corrected Ltr Transmitting Unit 1 Fourth Refueling Outage (1REO4) ISI Summary Rept for Repairs & Replacements Performed Under ASME Code,Section Xi.W/O Encl + (ML20035D596)
- ML20035D603 + (ML20035D603)
- ML20035D607 + (ML20035D607)
- ML20035D609 + (ML20035D609)