ML20035D548

From kanterella
Jump to navigation Jump to search

Notifies NRC of Completion of Human Engineering Discrepancies Ref in Se, of Detailed Control Room Design Review
ML20035D548
Person / Time
Site: Brunswick  
Issue date: 03/30/1993
From: Mccarthy D
CAROLINA POWER & LIGHT CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NLS-93-095, NLS-93-95, TAC-M56107, TAC-M56108, NUDOCS 9304130306
Download: ML20035D548 (1)


Text

/

gpag Carolina Power & Light Company MAR 3 01903 SERIAL: NLS-93-095 United States Nuclear Regulatory Commission ATTENTION: Document Control Desk Washington, DC 20555 BRUNSWICK STEAM ELECTRIC PLANT, UNIT NOS.1 AND 2 DOCKET NOS. 50-325 & 50-324/ LICENSE NOS. DPR-71 & DPR-62 NOTIFICATION OF COMPLETION OF DETAILED CONTROL ROOM DESIGN REVIEW HUMAN ENGINEERING DISCREPANCIES (HEDs) (NRC TAC NOS/56107 andF56108)

Gentlemen:

l I

The purpose of this letter is to notify the NRC of the completion of the Human Engineering Discrepancies (HEDs) referenced in the NRC's Safety Evaluation, dated November 2,1989, of the Brunswick Detailed Control Room Design Review (DCRDR). The NRC Safety Evaluation requested Carolina Power & Light Company (CP&L) address corrective actions for three Emergency Operating Procedure (EOP) instrumentation HEDs and provide a description of the results of the disposition of the 206X-2106 " joy stick zoning" HED, along with the schedule for implementing any associated i

corrective action.

l By letter dated January 5,1990, CP&L responded to the NRC's request to address corrective j

(

actions for three EOP instrumentation HEDs and provided the disposition of the " joy stick zoning" l

HED. The corrective actions for the three EOP instrumentation HEDs were as proposed in Revision 1 to the Brunswick DCRDR Final Summary Report, dated June 23,1987 (NLS-87-123).

These modifications were completed with paperwork closeout dated March 21,1991 for Unit 1, and December 19,1991 for Unit 2. The disposition of the " joy stick zoning" was also as stated in Revision 1 to the Brunswick DCRDR Final Summary Report, and these modifications were completed with paperwork closeout dated February 28,1993 for Unit 1, and December 9,1991 for Unit 2.

l Please refer any questions regarding this submittal to Mr. D. B. Waters at (919) 546-3678.

Yours very truly, b

D. C. McCarthy Manager Nuclear Licensing Section SHC/she (nts93095.wpf) cc:

Mr. S. D. Ebneter

(

l Mr. P. D. Milano l O) e n

- n r

'L 1

Mr. R. L. Prevatte l

E%ag -4,

. wwygmm

/[

l C2760[

i 411 r yencone street

  • P. O ac, int. p.,,,9n N

e t

l l

9304130306 930330

    1. EN" "N h""=n PDR ADOCK 05000324 P

PDR