- 05000277/LER-1981-042-03, /03L-0:on 811021,gland Seal Condenser Bottom Head Gasket Developed Leak & HPCI Sys Declared Inoperable.Caused by Displacement of Gasket on Sealing Surface Between Condenser Shell & Bonnet + (ML20033C921)
- ML20033C922 + (ML20033C922)
- ML20033C923 + (ML20033C923)
- ML20033C924 + (ML20033C924)
- ML20033C925 + (ML20033C925)
- ML20033C928 + (ML20033C928)
- 05000237/LER-1981-064, Forwards LER 81-064/03L-0 + (ML20033C930)
- ML20033C932 + (ML20033C932)
- ML20033C933 + (ML20033C933)
- 05000237/LER-1981-064-03, /03L-0:on 811029,during Pressure Suppression to Vacuum Breaker Dis 1600-3,pressure Switch Trip Point Exceeded Tech Spec.Caused by Setpoint Drift.Valve Readjusted + (ML20033C934)
- ML20033C935 + (ML20033C935)
- ML20033C937 + (ML20033C937)
- ML20033C938 + (ML20033C938)
- ML20033C939 + (ML20033C939)
- ML20033C940 + (ML20033C940)
- ML20033C941 + (ML20033C941)
- ML20033C942 + (ML20033C942)
- ML20033C945 + (ML20033C945)
- ML20033C946 + (ML20033C946)
- ML20033C947 + (ML20033C947)
- 05000286/LER-1981-008, Forwards LER 81-008/01T-0.Detailed Event Analysis Encl + (ML20033C948)
- ML20033C950 + (ML20033C950)
- ML20033C951 + (ML20033C951)
- ML20033C952 + (ML20033C952)
- 05000286/LER-1981-008-01, /01T-0:on 811109,at Hot Shutdown,Two Manual Isolation Vlaves in Weld Channel & Containment Penetration Pressurizaiton Sys Were Closed.Caused by Administrative Error.Valves Opened + (ML20033C953)
- 05000263/LER-1981-024, Forwards LER 81-024/01T-0 + (ML20033C954)
- ML20033C956 + (ML20033C956)
- ML20033C957 + (ML20033C957)
- ML20033C958 + (ML20033C958)
- 05000263/LER-1981-024-01, /01T-0:on 811112,during Maint Shutdown & PM on Hpci,Discovered Abnormal Wear in Woodwear Governor Bracket. Caused by Failed Components Due to Thrust Washer Failure Causing Bushings to Seize to Shaft & Distort Casing + (ML20033C961)
- ML20033C962 + (ML20033C962)
- ML20033C964 + (ML20033C964)
- ML20033C965 + (ML20033C965)
- ML20033C966 + (ML20033C966)
- ML20033C967 + (ML20033C967)
- ML20033C968 + (ML20033C968)
- ML20033C969 + (ML20033C969)
- ML20033C971 + (ML20033C971)
- ML20033C972 + (ML20033C972)
- ML20033C973 + (ML20033C973)
- ML20033C974 + (ML20033C974)
- ML20033C975 + (ML20033C975)
- 05000255/LER-1981-048, Forwards LER 81-048/03L-0 + (ML20033C976)
- 05000219/LER-1981-051, Forwards LER 81-051/03L-0.Detailed Event Analysis Encl + (ML20033C978)
- ML20033C980 + (ML20033C980)
- ML20033C981 + (ML20033C981)
- ML20033C982 + (ML20033C982)
- 05000255/LER-1981-048-03, /03L-0:on 811025,open Fire Barrier Found in West Engineered Safeguards Pump Room W/O Fire Watch Required by Tech Specs.Caused by Personnel Oversight.Personnel Instructed in Responsibility for Fire Watches + (ML20033C983)
- ML20033C984 + (ML20033C984)
- 05000219/LER-1981-051-03, /03L-0:on 811017,high Pressure Switch IE83E Found to Trip Higher than Tech Spec Limit.Caused by Instrument Setpoint Drift.Switch Reset + (ML20033C985)
- ML20033C986 + (ML20033C986)