List of results
- ML20028F399 + (ML20028F399)
- 05000361/LER-1982-170, Forwards LER 82-170/03L-0.Detailed Event Analysis Submitted + (ML20028F400)
- ML20028F401 + (ML20028F401)
- 05000317/LER-1982-082, Forwards LER 82-082/03L-0 + (ML20028F403)
- ML20028F405 + (ML20028F405)
- ML20028F408 + (ML20028F408)
- ML20028F409 + (ML20028F409)
- ML20028F414 + (ML20028F414)
- 05000317/LER-1982-082-03, /03L-0:on 821227,noted Continuous Control Element Assembly Motion Inhibit (CMI) Signal in Effect Causing CMI to Be Inoperable Whenever Control Element Assemblies Moved. Cause Unknown.Cmi Alarm Relay Replaced + (ML20028F416)
- ML20028F417 + (ML20028F417)
- ML20028F418 + (ML20028F418)
- ML20028F422 + (ML20028F422)
- ML20028F423 + (ML20028F423)
- 05000305/LER-1982-035, Forwards LER 82-035/03L-1 + (ML20028F424)
- ML20028F425 + (ML20028F425)
- 05000272/LER-1983-001-03, /03L-0:on 830104,vital Bus 1B Tripped,Rendering RHR Loop Inoperable.Caused by Differential Relay Protection. Redundant RHR Loop Immediately Placed in Operation + (ML20028F426)
- ML20028F428 + (ML20028F428)
- 05000361/LER-1982-170-03, /03L-0:on 821214,review of Chart Recordings of RCS Cold Leg Temp Indicated Heatup/Cooldown Rate Limits Exceeded on Three Occasions.Caused by Inability to Properly Control Shutdown Cooling Sys Flow.Personnel Counseled + (ML20028F429)
- IR 05000320/1982012 + (ML20028F430)
- 05000317/LER-1982-084, Forwards LER 82-084/03L-0 + (ML20028F432)
- ML20028F433 + (ML20028F433)
- ML20028F435 + (ML20028F435)
- 05000305/LER-1982-035-03, /03L-1:on 821216,during Full Power Operation, Pinhole Leak Discovered in Suction Line from Vol Control Tank to Charging Pumps.Caused by Vibrations & Pulsations in Associated Piping.Leak Plugged + (ML20028F436)
- ML20028F438 + (ML20028F438)
- 05000317/LER-1982-084-03, /03L-0:on 821223,sequencer Initiated Alarm Failed to Clear When Diesel Generator 12 Shut Down.Caused by Failure of Breaker Lever to Operate Auxiliary Switch in Cubicle Due to Displaced Assembly.New Assembly Installed + (ML20028F439)
- ML20028F441 + (ML20028F441)
- ML20028F443 + (ML20028F443)
- ML20028F444 + (ML20028F444)
- ML20028F446 + (ML20028F446)
- ML20028F447 + (ML20028F447)
- 05000325/LER-1982-125, Forwards LER 82-125/03L-0 + (ML20028F449)
- ML20028F450 + (ML20028F450)
- ML20028F451 + (ML20028F451)
- ML20028F455 + (ML20028F455)
- IR 05000193/1982002 + (ML20028F456)
- ML20028F458 + (ML20028F458)
- 05000324/LER-1982-134, Forwards LER 82-134/03L-0 + (ML20028F460)
- ML20028F461 + (ML20028F461)
- ML20028F463 + (ML20028F463)
- ML20028F465 + (ML20028F465)
- ML20028F467 + (ML20028F467)
- 05000324/LER-1982-134-03, /03L-0:on 821222,trip Module Showed Upscale Indication of Reactor Level While Local Meter Indicator of Redundant Instrument Showed Indication of 198.0 Inches. Caused by Transmitter Out of Calibr Due to Instrument Drift + (ML20028F468)
- 05000237/LER-1983-003, Forwards LER 83-003/03L-0 + (ML20028F469)
- ML20028F470 + (ML20028F470)
- IR 05000373/1982052 + (ML20028F471)
- 05000395/LER-1982-065-03, /03L-0:on 821222,electrical Power Lost to Train a Radiation Monitoring Sys.During Investigation of Loss of Power,Maint Personnel Accidently Short Circuited Train B. Caused by Blown Power Fuses Due to Personnel Error + (ML20028F472)
- ML20028F474 + (ML20028F474)
- ML20028F476 + (ML20028F476)
- ML20028F477 + (ML20028F477)
- 05000237/LER-1983-003-03, /03L-0:on 830108,during Surveillances Dis 1400-5 & DOS 6600-1,diesel Generator Low Water Pressure Alarm Received.Caused by Bad Low Cooling Water Pressure Switch. Switch Replaced W/Class 9012 Type GAW-5 + (ML20028F479)
- IR 05000255/1982030 + (ML20028F480)