Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20011D325 + (ML20011D325)
- ML20011D327 + (ML20011D327)
- ML20011D328 + (ML20011D328)
- ML20011D330 + (ML20011D330)
- ML20011D331 + (ML20011D331)
- 05000414/LER-1989-021-02, :on 890821,hydrogen Skimmer Fan 2A Declared Inoperable in Order to Replace Breaker,In Response to NRC Bulletin 88-010.On 890825,breaker Tripped & Power Reduction Resumed.Caused by Inappropriate Action + (ML20011D332)
- ML20011D333 + (ML20011D333)
- ML20011D334 + (ML20011D334)
- 05000413/LER-1989-027-01, :on 891120,chemical & Vol Control Sys Centrifugal Charging Pump 1B Declared Inoperable Due to Inability to Maintain Sufficient Charging Flow.Cause Not determined.Power-range Detector Replaced + (ML20011D335)
- ML20011D336 + (ML20011D336)
- ML20011D337 + (ML20011D337)
- ML20011D338 + (ML20011D338)
- ML20011D339 + (ML20011D339)
- ML20011D340 + (ML20011D340)
- ML20011D342 + (ML20011D342)
- ML20011D343 + (ML20011D343)
- IR 05000445/1989082 + (ML20011D345)
- ML20011D346 + (ML20011D346)
- ML20011D348 + (ML20011D348)
- ML20011D349 + (ML20011D349)
- IR 05000416/1989028 + (ML20011D351)
- ML20011D355 + (ML20011D355)
- ML20011D358 + (ML20011D358)
- ML20011D362 + (ML20011D362)
- LIC-89-1148, Submits Supplemental Info Re Insp Rept 50-285/89-01.Survey of Maint Orders Issued Prior to & Including 1976 Will Be Conducted in Order to Provide Reasonable Assurance That Adequate Reviews Performed + (ML20011D363)
- ML20011D367 + (ML20011D367)
- ML20011D369 + (ML20011D369)
- ML20011D370 + (ML20011D370)
- AECM-89-0228, Forwards Response to 891101 Request for Addl Info Re Dcrdr. Human Factors Specialists & Util Personnel Trained in Human Factors Currently Involved in Dcrdr Program.Supplemental Summary Rept Will Be Submitted to NRC by 900430 + (ML20011D372)
- IR 05000321/1989032 + (ML20011D373)
- ML20011D374 + (ML20011D374)
- 1CAN128910, Forwards B&W Owners Group Response to Question 5.9 of NRC 890817 Request on BAW-2085 Re NRC Bulletin 88-011, Pressurizer Surge Line Thermal Stratification, Per + (ML20011D375)
- ML20011D376 + (ML20011D376)
- ML20011D377 + (ML20011D377)
- ML20011D378 + (ML20011D378)
- ML20011D384 + (ML20011D384)
- ML20011D386 + (ML20011D386)
- ML20011D388 + (ML20011D388)
- LIC-89-1175, Forwards Application for Amend to License DPR-40,lowering Allowed Max Ambient Temp in Control Room in Tech Spec 2.12 + (ML20011D390)
- ML20011D391 + (ML20011D391)
- ML20011D392 + (ML20011D392)
- ML20011D393 + (ML20011D393)
- ML20011D394 + (ML20011D394)
- ML20011D395 + (ML20011D395)
- ML20011D399 + (ML20011D399)
- ML20011D400 + (ML20011D400)
- ML20011D401 + (ML20011D401)
- LIC-89-1173, Forwards Application for Amend to License DPR-40,revising Limiting Conditions for Operation for Chemical & Vol Control Sys + (ML20011D402)
- ML20011D403 + (ML20011D403)
- ML20011D405 + (ML20011D405)
- ML20011D406 + (ML20011D406)