ML20011D349

From kanterella
Jump to navigation Jump to search
Forwards Insp Rept 50-416/89-28 on 891021-1117.Violation Noted But Not Cited Since Criteria for Categorization of licensee-identified Violations Met
ML20011D349
Person / Time
Site: Grand Gulf 
Issue date: 12/13/1989
From: Verrelli D
NRC Office of Inspection & Enforcement (IE Region II)
To: Cottle W
System Energy Resources
Shared Package
ML20011D350 List:
References
NUDOCS 8912270015
Download: ML20011D349 (2)


See also: IR 05000416/1989028

Text

p,

-

..

.

'

DEC 131989

'

Docket No.

50-416

License No. NPF 29

System Energy Resources. Inc.

ATTN: Mr. W. T. Cottle

.;

P.O. Box 23054

.

Vice President. Nuclear Operations

y

Jackson. MS 39205

j

Gentlemen:

SUBJECT: NRC INSPECTION REPORT NO. 50-416/89-28

l

'

This refers to the Nuclear Regulatory Commission (NRC) inspection conducted by

H. O. Christensen on October 21 through November 17, 1989.

The inspection

included a review of activities authorized for your Grand Gulf facility.

At

the conclusion of the inspection. the findings were discussed with those

members of your staff identified in the enclosed inspection report.

?

Areas examined during the inspection are identified in the report.

Within

these areas, the inspection consisted of selective examinations of procedures

and representative records. interviews with personnel, and observation of

activities in progress.

The inspection findings indicate that certain activities appeared to violate NRC

!

requirements.

However, because all of the criteria for cateperization of

licensee-identified violations were met, the violations are not being cited.

,

The details pertaining to the licensee-identified violations are described in

the enclosed Inspection Report.

.

In accordance with Section 2.790 of the NRC's " Rules of Practice."

Part 2.

Title 10. Code = of Federal Regulations, a copy of this . letter and its enclosure

will.be placed in the NRC Public Document Room.

Should you have any questions concerning this letter, please contact us.

Sincerely.

ORIGINAL SIGNfD BY

DAVID M. VERRELU

David M. Verre111. Chief

Reactor Projects Branch 1

Division of Reactor Projects

Enclosure: (See page 2)

L

4

s \\

-

8912270015 891213

PDR- ADOCK 05000416

gg /

O

= }fDC

-

s

- a -a.

.

..

9

.

System Energy Resources. Inc.

2

DEC 131989

Enclosure:

NRC Inspection Report

cc w/ enc 1:

T. H. Cloninger. Vice President

The Honorable William J. Guste. Jr.

Nuclear Engineering and Support

Attorney General

System Energy Resources. Inc.

Department of Justice

P. O. Box 31995

State of Louisiana

>

Jackson. MS 39286

Baton Rouge. LA 70804

C. R. Hutchinson. General Manager

Office of the Governor

Grand Gulf Nuclear Station

State of Mississippi

System Energy Resources. Inc.

Jackson MS 39201

P. O. Box 756

Port Gibson, MS 39150

Attorney General

Gartin Building

J. G. Cesare. Director

Jackson. MS 39205

Nuclear Licensing

System Energy Resources. Inc.

Jack McMillan. Director

P. O. Box 469

Division of Solid Waste Management

Port Gibson. MS 39150

Mississippi Department of

Natural Resources

Mr. Ralph T. Lally

P. O. Box 10385

Manager of Quality Assurance

Jackson, MS 39209

Entergy Services. Inc.

P. O. Box 31995

Presidert

Jackson, MS 39286

Clairborne County Board

cf Supervisors

R. B. McGehee. Esq.

Port Gibson, MS 39150

Wise. Carter. Child, and Caraway

P. O. Box 651

State of Mississippi

Jackson. MS 39205

bec w/ enc 1:

N. S. Reynolds. Esq.

L. Kintner. NRR

Bishop. Cook. Purcell & Reynolds

Document Control Desk

1400 L Street. NW - 12th Floor

Washington

D. C.

20005-3502

NRC Resident Inspector

U.S. Nuclear Regulatory Commission

C. B. Hogg. Project Manager

Route 2. Box 39P

Bechtel Power Corporation

Port Gibson. MS 39150

P. O. Box 2166

Houston. TX 77252-2166

Alton B. Cobb, M.D.

State Health Office

State Board of Health

P. O. Box 1700

Jackson, MS 39205

rib R

RII:D P

almain

hFCan'rell

-

12/12/89

12/t 89