Application for Amend to License DPR-40,lowering Allowed Max Ambient Temp in Control Room in Tech Spec 2.12
ML20011D393
Person / Time
Site: Fort Calhoun 
Issue date: 12/20/1989
From: Morris K
OMAHA PUBLIC POWER DISTRICT
To:
Shared Package
ML20011D391 List:
References
NUDOCS 8912270115
Download: ML20011D393 (4)


Text

_____

BEFORE THE UNITED STATES NUCLEAR REGULATORY COMMISSION In the Matter of Omaha Public Power District Docket No. 50-285 (Fort Calhoun Station Unit No. 1)

APPLICATION FOR AMENDMENT OF OPERATING LICENSE Pursuant to Section 50.90 of the regulations of the U. S. Nuclear Regulatory Commission ("the Commission"), Omaha Public Power District, holder of facility Operating License No. DPR-40, herewith requests that the Technical Specifications set forth in Appendix A to that License be amended to lower the maximum allowable ambient temperature in the Control Room.

The proposed changes in Technical Specifications are discussed in Attachment A to this Application. A discussion, Justification and no Significant Hazards Consideration Analysis, which demonstrates that the proposed changes do not involve significant hazards considerations, is appended in Attachment B.

The proposed changes in specifications would not authorize any change in the types or any increase in the amounts of effluents or a change in the authorized power level of the facility.

WHEREFORE, Applicant respectfully requests that Section 2 of Appendix A to Facility Operating License No. DPR-40 be amended in the form attached hereto as Attachment A.

9912270115 891220

t l

l t

BEFORE THE UNITED STATES NUCLEAR REGULATORY COMMISSION l

In the Matter of Omaha Public Power District Docket No. 50-285 i

(Fort Calhoun Station

[

UnitNo.1)

APPLICATION FOR AMENDMENT 0F OPERATING LICENSE Pursuant to Section 50.90 of the regulations of the U. S. Nuclear Regulatory Commission ("the Commission"), Omaha Public Power District, holder of Facility Operating License No. DPR-40, herewith requests that the Technical Specifications set forth in Appendix A to that License be amended to lower the maximum allowable ambient temperature in the Control Room.

The proposed changes in Technical Specifications are discussed in Attachment A to this Application. A discussion, Justification and no Significant Hazards Consideration Analysis, which demonstrates that the proposed changes do not involve significant hazards considerations, is appended I

in Attachment B.

The proposed changes in specifications would not authorize i

any change in the types or any increase in the amounts of effluents or a change

[

in the authorized power level of the facility.

1 WHEREFORE, Applicant respectfully requests that Section 2 of Appendix A to Facility Operating License No. DPR-40 be amended in the form' attached hereto as l

Attachment A.

r t

i 8912270115 891220."

PDR ADOCK 05000285 P

PDC

2-A copy of this Application, including its attachments, has been submitted to the Director - Nebraska State Division of Radiological Health, as required by 10 CFR 50.91.

OMAHA PUBLIC POWER DISTRICT By Did41Iion Manager Nuclear Operations Subscribed and sworn to before me this for#

day of December, 1989.

I kim h

Notary Public m <.,1.m..,.,_

j o& n :J T. L t.(- u os m un,aac

h 9

4 9

a

.w 4

ATTACHMENT A I

. l I

,- TES E M i t

  • 2. 0 LIMITING CONDITIONS FOR OPERATION r

2.12 Control Room Systems Applicability Applies to the control room air conditioning and filtering systems.

l Objective To limit the environmental conditions in the control room, under normal and post DBA conditions.

Specifications (1)

If the control room air temperature reaches 1200F, immediate action shall be taken to reduce this temperature.

If the temperature cannot be reduced to below 1200F in four hours, the reactor vill be placed in a hot shutdown condition.

(2)

A thermometer must be in the control room at all times.

(3)

All areas of the plant which have safety related instrumentation vill be observed during hot functional testing to determine local temperatures and monitored during operation if normal plant ventilation is not available.

(b)

From and after the date that the control room air treatment system is made or found to be inoperable for any reason, reactor operation is permissable only during the succeeding seven days unless such circuit is sooner made operable.

If these conditions cannot be met, the reactor shall be placed in cold shutdown condition within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

Sasis The reactor protective system and the engineered safeguards system were designed for and the instrumentation was tested at 120 F, 0

Therefore, if the temperature of the control room exceeds 1200F, the reactor vill be shutdown and the conditions corrected to preclude failure of components in an untested environment.

If the centrol room air treatment system is found to be inoperable, there is no immediate threat to the control room and reactor opera-tion may continue for a limited period of time while repairs are being made.

If the system cannot be repaired within seven (i) days, the reactor is shutdown zad brought to cold shutdown within 2h hours.

2-59 Amendment No.15