- IR 05000317/1981011 + (ML20010G163)
- 05000318/LER-1981-036-03, /03L-0:on 810804,during Normal Operation,Reactor Protection Sys Channel B Hi Power,Thermal Margin/Low Pressure & Axial Shape Index Units Were Bypassed.Caused by Nuclear Instrumentation Power Spikes Causing Spurious Trips + (ML20010G165)
- ML20010G166 + (ML20010G166)
- ML20010G168 + (ML20010G168)
- 05000267/LER-1981-045-03, /03L-0:on 810727,during Normal Startup Operation, Primary Coolant Dewpoint Exceeded Tech Spec Limits.Caused by Contamination Due to Moisture.Contaminants Removed from Primary Coolant + (ML20010G169)
- ML20010G170 + (ML20010G170)
- ML20010G171 + (ML20010G171)
- 05000315/LER-1981-034, Forwards LER 81-034/03L-0 + (ML20010G173)
- ML20010G174 + (ML20010G174)
- 05000368/LER-1981-028, Forwards LER 81-028/03L-0 + (ML20010G175)
- ML20010G176 + (ML20010G176)
- ML20010G177 + (ML20010G177)
- ML20010G178 + (ML20010G178)
- IR 05000289/1981007 + (ML20010G179)
- 05000315/LER-1981-034-03, /03L-0:on 810804,during Power Reduction, Pressurizer Pressure Dropped Below Min Tech Specs.Caused by Turbine Load Reduction Rate Being Greater than Reactor Power Reduction Rate.Event Will Be Reviewed by Operators + (ML20010G182)
- ML20010G183 + (ML20010G183)
- ML20010G184 + (ML20010G184)
- ML20010G185 + (ML20010G185)
- ML20010G186 + (ML20010G186)
- ML20010G187 + (ML20010G187)
- ML20010G188 + (ML20010G188)
- ML20010G189 + (ML20010G189)
- 05000368/LER-1981-028-03, /03L-0:on 810725,during Mode 1 Operation,Charging Pump 2P36A Seal Failed.Caused by Malfunctioning Discharge Check Valve Due to Foreign Matl Trapped Between Disc & Seat. Pump & Valve Repaired + (ML20010G191)
- ML20010G192 + (ML20010G192)
- ML20010G193 + (ML20010G193)
- ML20010G194 + (ML20010G194)
- ML20010G195 + (ML20010G195)
- ML20010G196 + (ML20010G196)
- ML20010G197 + (ML20010G197)
- ML20010G200 + (ML20010G200)
- ML20010G201 + (ML20010G201)
- ML20010G202 + (ML20010G202)
- ML20010G203 + (ML20010G203)
- ML20010G204 + (ML20010G204)
- ML20010G205 + (ML20010G205)
- ML20010G206 + (ML20010G206)
- FVY-81-130, Responds to IE Bulletin 81-02,Suppl 1, Failure of Gate Type Valves to Close Against Differential Pressure. Affected Valves Are Not Installed or Maintained as Spares at Facility.Response Required 16 Manhours + (ML20010G207)
- ML20010G208 + (ML20010G208)
- 05000316/LER-1981-041, Forwards LER 81-041/03L-0 + (ML20010G211)
- ML20010G212 + (ML20010G212)
- ML20010G213 + (ML20010G213)
- ML20010G215 + (ML20010G215)
- ML20010G217 + (ML20010G217)
- ML20010G219 + (ML20010G219)
- 05000316/LER-1981-041-03, /03L-0:on 810806,RCS Unidentified Leakage Exceeded Tech Spec Limit.Caused by Packing Leak on Valve RC-10811. Valve Repacked.Resistance Temp Detector Loop Hand Valves to Be Checked for Packing Leaks During Next Outage + (ML20010G220)
- IR 05000352/1981011 + (ML20010G221)