- ML20009D751 + (ML20009D751)
- 05000318/LER-1981-033, Forwards LER 81-033/03L-0 + (ML20009D753)
- ML20009D754 + (ML20009D754)
- 05000295/LER-1981-004, Forwards Updated LER 81-004/03X-1 + (ML20009D755)
- ML20009D757 + (ML20009D757)
- 05000318/LER-1981-033-03, /03L-0:on 810704,pressurizer Level Deviated Excessively from Program Level While Paralleling Main Turbine Generator.Caused by RCS Temp Swing,Not Uncommon During Paralleling Process + (ML20009D759)
- 05000295/LER-1981-004-03, Microswitch 2FIC-611A, Controlling Only Valve on RHR Recirculation Line B,Found to Be Defective.Caused by Faulty Procedure Used to Check Switch Calibr.Procedure Revised & Switches Tested + (ML20009D760)
- ML20009D762 + (ML20009D762)
- 05000304/LER-1981-014, Forwards LER 81-014/03L-0 + (ML20009D764)
- ML20009D766 + (ML20009D766)
- ML20009D767 + (ML20009D767)
- 05000304/LER-1981-014-03, /03L-0:on 810619,svc Water Inlet Valve to RCFC, 2MOVSW0002,failed to Stroke Open on Train B Actuation Signal Per Tech Spec,During Quarterly Safeguard Surveillance.Cause Not Determined + (ML20009D768)
- ML20009D769 + (ML20009D769)
- 05000334/LER-1981-059, Forwards LER 81-059/03L-0 + (ML20009D770)
- ML20009D772 + (ML20009D772)
- ML20009D773 + (ML20009D773)
- 05000334/LER-1981-059-03, /03L-0:on 810615,battery Charger Supply to 125-volt Dc Bus 1-2 Lost When Battery Charger 2 Output Breaker Tripped Open.Caused by Excessive Heat in Emergency Switchgear Area.Fan Placed by Charger + (ML20009D775)
- IR 05000321/1981011 + (ML20009D776)
- IR 05000324/1981010 + (ML20009D778)
- ML20009D781 + (ML20009D781)
- ML20009D782 + (ML20009D782)
- ML20009D786 + (ML20009D786)
- ML20009D790 + (ML20009D790)
- IR 05000566/1981006 + (ML20009D791)
- ML20009D792 + (ML20009D792)
- 05000249/LER-1981-014, Forwards LER 81-014/03L-0 + (ML20009D794)
- ML20009D795 + (ML20009D795)
- 05000334/LER-1981-058, Forwards LER 81-058/03L-0 + (ML20009D796)
- ML20009D797 + (ML20009D797)
- IR 05000328/1981029 + (ML20009D798)
- 05000334/LER-1981-058-03, /03L-0:on 810610,refueling Water Storage Tank Level Indicator LI-QS-100A Failed Low.Caused by Failure of Force Motor within Low Loop Level Transmitter.Transmitter Repaired & Replaced on 810624 + (ML20009D799)
- 05000320/LER-1981-015, Forwards LER 81-015/01L-0 + (ML20009D800)
- 05000317/LER-1981-017, Forwards Updated LER 81-017/03X-1 + (ML20009D802)
- ML20009D803 + (ML20009D803)
- ML20009D804 + (ML20009D804)
- 05000249/LER-1981-014-03, /03L-0:on 810616,during Scram Air Sys Header Pressure Switch Calibr,Pressure Switches 3-302-99A & B Actuated W/Setpoint Lower than Required.Caused by Instrument Setpoint Drift.Switches Reset + (ML20009D806)
- 05000317/LER-1981-017-03, Inboard Bearing Found Scored When Auxiliary Feedwater Pump 12 Taken Out of Svc for Insp.Apparently Caused by Improper Oil Level or Contaminated Oil.Markings Added to Sightglasses & Maint Program Modified + (ML20009D807)
- 05000255/LER-1981-026, Forwards LER 81-026/03L-0 + (ML20009D809)
- ML20009D810 + (ML20009D810)
- IR 05000369/1981018 + (ML20009D811)
- 05000255/LER-1981-026-03, /03L-0:on 810626,during Diesel Generator 1-1 Test Startup,Engine Failed to Reach Rated Speed.Caused by Motor Failure in Potentiometer in Engine Speed Control Circuit. Motor Replaced + (ML20009D815)
- B10233, Submits Comments on 810707-10 Environ Qualification Meeting in Bethesda,Md.Issuance of Another Bulletin Suppl or Generic Ltr Would Further Util Understanding of NRC Positions + (ML20009D816)
- ML20009D817 + (ML20009D817)
- 05000155/LER-1981-013, Forwards LER 81-013/03L-0 + (ML20009D819)
- IR 05000424/1981005 + (ML20009D821)
- 05000155/LER-1981-013-03, /03L-0:on 810617,reactor Depressurization Sys Loop B Was Removed from Svc to Check Inverter Power Supply.Caused by Defective Electronic Components in non-essential Synchronizing Circuit.Components Will Be Replaced + (ML20009D824)