- ML20008F639 + (ML20008F639)
- 05000333/LER-1981-025, Forwards LER 81-025/03L-0 + (ML20008F641)
- ML20008F642 + (ML20008F642)
- 05000333/LER-1981-025-03, /03L-0:on 810323,while Conducting Surveillance During Normal Operation,Reactor Water Level Switch Found Set Contrary to Tech Specs.Caused Attributed to Instrument Drift.Switch Adjusted & Weekly Surveillance Performed + (ML20008F643)
- ML20008F646 + (ML20008F646)
- 05000267/LER-1981-017, Forwards LER 81-017/03L-0 + (ML20008F648)
- ML20008F649 + (ML20008F649)
- 05000267/LER-1981-017-03, /03L-0:on 810217,standby Diesel Engine 1B Tripped on High Cooling Water Temp.Caused by Sticking Temp Control Valve.Valve Disassembled,Cleaned & Returned to Svc + (ML20008F650)
- 05000327/LER-1981-036, Forwards LER 81-036/03L-0 + (ML20008F652)
- ML20008F653 + (ML20008F653)
- 05000327/LER-1981-036-03, /03L-0:on 810320,remote Shutdown Monitoring Channel for Steam Generator 4 Pressure Declared Inoperable. Caused by Blown Fuse in Loop Power Supply.Fuse Replaced + (ML20008F655)
- 05000267/LER-1981-021, Forwards LER 81-021/03L-0.Detailed Event Analysis Encl + (ML20008F656)
- ML20008F657 + (ML20008F657)
- ML20008F658 + (ML20008F658)
- 05000267/LER-1981-021-03, /03L-0:on 810302,liquid Nitrogen Storage Tank Level Lower than Tech Spec Requires.Caused by Sys Usage & Unavailable Recondensers.Level Restored W/Two Loads + (ML20008F660)
- ML20008F661 + (ML20008F661)
- ML20008F663 + (ML20008F663)
- B10170, Submits Info Re Revision 4 to Facility Modified Amended Security Plan.Info Withheld (Ref 10CFR2.790) + (ML20008F664)
- ML20008F665 + (ML20008F665)
- AECM-81-135, Forwards Clarifications & Exceptions to ANSI N18.1-1971 Re Selection & Training of Nuclear Power Plant Personnel.Review & Reply Requested + (ML20008F666)
- ML20008F668 + (ML20008F668)
- ML20008F669 + (ML20008F669)
- ML20008F670 + (ML20008F670)
- ML20008F673 + (ML20008F673)
- ML20008F675 + (ML20008F675)
- ML20008F678 + (ML20008F678)
- 05000267/LER-1981-020, Forwards LER 81-020/03L-0.Detailed Event Analysis Encl + (ML20008F679)
- ML20008F680 + (ML20008F680)
- 05000348/LER-1981-007, Forwards LER 81-007/01T-0 + (ML20008F681)
- ML20008F682 + (ML20008F682)
- ML20008F683 + (ML20008F683)
- ML20008F685 + (ML20008F685)
- 05000267/LER-1981-020-03, /03L-0:on 810226,primary Coolant Moisture & Oxidants Exceeded Limits.Caused by Circulator Buffer Sys Upset & Helium Circulator Trip Due to 810223 Reactor Scram. Reactor Power Reduced Until Moisture Level Decreased + (ML20008F687)
- 05000348/LER-1981-007-01, /01T-0:on 810402,mathematical Sign Error Was Found in Load Summation in Turbine Driven Auxiliary Feedwater Pump Nozzle Load Design Analysis.Caused by Designer Error. Seismic Restraint Mod Made + (ML20008F688)
- ML20008F689 + (ML20008F689)
- ML20008F691 + (ML20008F691)
- ML20008F693 + (ML20008F693)
- ML20008F694 + (ML20008F694)
- RBG-10-034, Final Deficiency Rept Re Incorrect Input to Finite Element Model Used to Calculate Amplified Floor Response Spectra of Reactor Bldg,Initially Reported on 800912.Concludes Condition Not Reportable Per 10CFR50.55e + (ML20008F695)
- 05000254/LER-1981-007, Forwards LER 81-007/03L-0 + (ML20008F696)
- ML20008F697 + (ML20008F697)
- ML20008F698 + (ML20008F698)
- 05000254/LER-1981-007-03, /03L-0:on 810313,no Position Indication Found on Recirculation Pump 1A Discharge Valve MO-1-202-5A.Caused by Tripped Valve Motor Breaker Due to Several Shorted Conductors in Cable 12507 Leading to Valve Inside Drywell + (ML20008F699)
- A810014, Responds to NUREG-0737 Items II.K.3.16 & 18 Re Reduction of Challenges & Failures of Relief Valves & Mod to Automatic Depressurization Sys Logic,Respectively + (ML20008F700)
- ML20008F701 + (ML20008F701)
- 05000298/LER-1981-003, Forwards LER 81-003/03L-0.Detailed Event Analysis Encl + (ML20008F703)
- ML20008F704 + (ML20008F704)
- ML20008F705 + (ML20008F705)
- ML20008F706 + (ML20008F706)
- 05000298/LER-1981-003-03, /03L-0:on 810223,RHR-MO-26B Motor Amps Increased & Remained Excessively High When Valve Reached Closed Position.Caused by Limit Switch on Limitorque SMB-O Valve Motor Operator Not Opening & de-energizing Starter + (ML20008F707)
- ML20008F708 + (ML20008F708)