ML20008F697

From kanterella
Jump to navigation Jump to search
Forwards LER 81-007/03L-0
Date released: 01/22/2020 Download: ML20008F697


LER 81-007/03L-0:on 810313,no Position Indication Found on Recirculation Pump 1A Discharge Valve MO-1-202-5A.Caused by Tripped Valve Motor Breaker Due to Several Shorted Conductors in Cable 12507 Leading to Valve Inside Drywell
ML20008F699
Person / Time
Site: Quad Cities 
Issue date: 04/01/1981
From: Kaeppel F
COMMONWEALTH EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML20008F699 (3)
Forwards LER 81-007/03L-0
ML20008F696
Person / Time
Site: Quad Cities 
Issue date: 04/01/1981
From: Kalivianakis N
COMMONWEALTH EDISON CO.
To: KEPPLER J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML20008F696 (1)