- ML20005A571 + (ML20005A571)
- IR 05000334/1981011 + (ML20005A573)
- 05000260/LER-1981-028-01, /01T-0:on 810611,while Performing Routine Surveillance Test SI 4.2.B.8 During Maint Outage,Reactor High Pressure Switches Ps 68-93 Switch 2 & Ps 68-94 Switch 2 Were Above Tech Spec Limits.Caused by Setpoint Drift + (ML20005A574)
- ML20005A575 + (ML20005A575)
- 05000312/LER-1981-030-04, /04T-0:on 810602,plant Effluent Ph Exceeded Limit. Caused by Fluctuating Ph of Water Supply.Negotiations Underway to Set Ph Limits Based on Max Observed Canal Ph in Previous 30 Days + (ML20005A576)
- ML20005A577 + (ML20005A577)
- 05000368/LER-1981-021-99, /99X-0:on 810528,RCS Iodine Levels Increased, Indicating Failure of 20 to 30 Fuel Rods.Cause Being Investigated by Periscope Exam of Rods & Discharged Bundles. Leaking Assemblies Isolated,Reconstituted & Resipped + (ML20005A578)
- ML20005A580 + (ML20005A580)
- ML20005A581 + (ML20005A581)
- ML20005A582 + (ML20005A582)
- ML20005A583 + (ML20005A583)
- ML20005A587 + (ML20005A587)
- ML20005A588 + (ML20005A588)
- ML20005A589 + (ML20005A589)
- ML20005A591 + (ML20005A591)
- ML20005A593 + (ML20005A593)
- ML20005A595 + (ML20005A595)
- TXX-3351, Informs That Analyses for Moderate & High Energy Pipe Breaks on Redundant Pump Rooms,Per ,Will Include Verification That Breaks Will Not Cause Unacceptable Flooding of Redundant Essential Equipment + (ML20005A597)
- ML20005A598 + (ML20005A598)
- 05000324/LER-1981-028, Forwards LER 81-028/01T-0 + (ML20005A599)
- ML20005A600 + (ML20005A600)
- ML20005A601 + (ML20005A601)
- ML20005A604 + (ML20005A604)
- ML20005A605 + (ML20005A605)
- ML20005A607 + (ML20005A607)
- ML20005A610 + (ML20005A610)
- IR 05000423/1981005 + (ML20005A611)
- 05000324/LER-1981-028-01, /01T-0:on 810610,while Performing Orderly Unit Shutdown,Shutdown Period Was Exceeded by 12 Minutes.Caused by Personnel Error.Personnel Reinstructed on Importance of Following Action Statements + (ML20005A613)
- ML20005A614 + (ML20005A614)
- IR 05000373/1981017 + (ML20005A615)
- ML20005A617 + (ML20005A617)
- ML20005A619 + (ML20005A619)
- ML20005A621 + (ML20005A621)
- ML20005A622 + (ML20005A622)
- ML20005A623 + (ML20005A623)
- ML20005A624 + (ML20005A624)
- ML20005A626 + (ML20005A626)
- ML20005A627 + (ML20005A627)
- ML20005A629 + (ML20005A629)
- ML20005A630 + (ML20005A630)
- IR 05000329/1981011 + (ML20005A631)
- ML20005A632 + (ML20005A632)
- ML20005A633 + (ML20005A633)
- ML20005A635 + (ML20005A635)
- 05000295/LER-1981-024, Forwards LER 81-024/03L-0 + (ML20005A638)
- ML20005A640 + (ML20005A640)
- ML20005A641 + (ML20005A641)
- ML20005A643 + (ML20005A643)
- 05000295/LER-1981-024-03, /03L-0:on 810522,control Room Intake to Turbine Bldg Air Radiation Monitor Indicated Failure.Cause Unknown. Monitor re-energized & Returned to Svc + (ML20005A644)
- ML20005A645 + (ML20005A645)
- 05000295/LER-1981-025, Forwards LER 81-025/03L-0 + (ML20005A647)