EPERGENCY PLAN IMPLEMENTING PROCEDURES INDEX Nt)48ER TITLE DATE 099-1 Reference Procedures 2-18-81 110-1 Station Director EPIP 4-30-81 120-1 Operations Director EPIP 2-18-81 130-1 Technical Director EPIP 2-18-81 140-1 Maintenance Director EPIP 2-18-81 15 0-1 Stores Director EPIP 2-18-81 160-1 Administrative Director EPIP 2-18-81 170-1 Security Director EPIP 2-18-81 180-1 Rad / Chem Director EPIP 2-lS-C',

190-1 Cemrnunications Director EPIP 2-18-81 310-1 Action and Notification 2-18-81 320-1 Activation of the GSEP Station Group 2-18-81 330-1 Classification of GSEP Conditions 6-09-81 330-2 Environs Procedure 2-18-81 330-3 Zion Environmental Surveillance Stations 2-18-81 330-4 Classification of an Incident involving Hazardous Material 2-18-81 340-1 Spill Prevention Control and Countermeasure Plans for Zion Nuclear Power Station 2-18-81 350-1 Quick Estimate of Offsite Oose from an Unplanned Release 5-21-81 360-1 Site Evacuation of Non-essential Personnel 2-18-81 360-2 Assembly Procedure m 2s e 370-1 Rescue and Recovery 2-18-81 APPROVED 8 r6166 3 00 Y77 b

1 DATE

ASSEMELY PROCEDURE 1

EPIP 360-2 TAS.E 7 CONTENTS SECTION TITLE PAT DATE RdVISION Table of Contents 1

aN 23 m' O

Purpose 2

KH 2 3 "*"

Q Reference 2

JuN 2 3 en 0

Prerequisites 2

JUN 2 3 W -

O Precautions 2

AN 2 3 a 0

Limitations and Actions 2

mN 2 3 a O

Procedure 2

JUN 2 3 -

0 3

JUN 2 3 m 0

l l

1 l

t I

This procedure contains 3 pages.

l' 1

DATE

EPIP 360-2 R2v. O JUN 2 3 190 Assembly Procedure A.

PURPOSE To assemble and account fcr all personnel 'within the protected area when warranted during a GSEP condition.

8.

REFERENCE EPIP 170 1 C.

PREREQUISITES None D.

PRECAUTIONS None E.

LIMITATION & ACTIONS 1.

Applies to people within the protected area only.

F.

PRO TDURE 1.

Initiate assembly by a two minute continuous siren and/or page announcement.

2.

Station groups are to report to the following areas listed:

A.

Control Room 1.

Operating people assigned to shift 8.

Technical Support Center 1.

GSEP Director and alternates 2.

Anyone assicped specific duties in TSC C.

Rad Protection Office 1.

All Rad Protection personnel D.

Maintenance Machine Shop 1.

Ofrice personnel 2.

Technical Staff 3.

Non-Shift Operating personnel 4.

All Maintenance personnel 5.

All persons in protected area not previously listed E.

Station Security force will stay on post under unless otherwise directed. Security Supervisor will account for all security personnel.

3.

Each supervisor will account for his people and forward to security at Ext. 505 all present or the name of any missing individual.

2

EPIP 360-2 Mv. 0 JUN 2 3 48 FROTDURE (Cont'd) 4.

Security Supervisor will advise each department of last kncwn whereabouts of missing personnel.

5.

Security Supervisor will advise Station or Operations Director of accountability results.

6.

During assembly procedure, Security will admit people into the protected area only on the authorization of the Station Director.

p 9

e FINAL 3