Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19343D625 + (ML19343D625)
- 05000333/LER-1981-031-03, /03L-0:on 810401,indicated Core Flow Appeared Higher than Expected.Possibly Caused by Error in Procedure That Sets Amplifier Gain Which Corrects Core Flow for Reverse Flow Through Idle Jet Pumps.Investigation Underway + (ML19343D626)
- ML19343D628 + (ML19343D628)
- ML19343D629 + (ML19343D629)
- ML19343D630 + (ML19343D630)
- ML19343D631 + (ML19343D631)
- W3P81-1168, Forwards Organization Chart Reflecting Change in Organizational Structure.Info Provided for Consideration in SER Scheduled for Issuance on 810530 + (ML19343D634)
- ML19343D635 + (ML19343D635)
- ML19343D636 + (ML19343D636)
- ML19343D698 + (ML19343D698)
- ML19343D755 + (ML19343D755)
- ML19343D794 + (ML19343D794)
- ML19343D843 + (ML19343D843)
- ML19343D918 + (ML19343D918)
- ML19343D971 + (ML19343D971)
- PLA-7830, Response to Second Request for Additional Information Regarding Proposed License Amendment Requesting a Temporary Change to the Technical Specifications to Allow Replacement of Emergency Service Water System Piping + (ML19343E412)
- ML19343E596 + (ML19343E596)
- ML19343E599 + (ML19343E599)
- ML19344A009 + (ML19344A009)
- ML19344A013 + (ML19344A013)
- ML19344A014 + (ML19344A014)
- ML19344A015 + (ML19344A015)
- ML19344A016 + (ML19344A016)
- ML19344A024 + (ML19344A024)
- ML19344A031 + (ML19344A031)
- ML19344A032 + (ML19344A032)
- ML19344A033 + (ML19344A033)
- ML19344A037 + (ML19344A037)
- ML19344A039 + (ML19344A039)
- ML19344A041 + (ML19344A041)
- 05000302/LER-1978-044, Forwards LER 78-044/03L-0 + (ML19344A042)
- 05000368/LER-1978-002, Forwards LER 78-002/01T-0 + (ML19344A045)
- ML19344A046 + (ML19344A046)
- 05000368/LER-1978-002-01, /01T-0 on 780920:during Inspec,Discovered That Valves Had an Interference Between Valve Gate & Gate Guide. Caused by Design Problem Which Could Prevent Complete Valve Closure.Valves Returned to Manufacturer for Repairs + (ML19344A047)
- 05000302/LER-1978-045, Forwards LER 78-045/03l-0 + (ML19344A048)
- ML19344A049 + (ML19344A049)
- 05000302/LER-1978-045-03, /03l-0 on 780907:closed Indication Not Received for Control Complex Air Supply Damper D-1 After Closed Command Was Issued.Caused by Mech Binding of Air Supply Damper.Preventive Maint Will Provide Corrective Action + (ML19344A050)
- ML19344A052 + (ML19344A052)
- ML19344A053 + (ML19344A053)
- ML19344A055 + (ML19344A055)
- ML19344A056 + (ML19344A056)
- ML19344A057 + (ML19344A057)
- ML19344A060 + (ML19344A060)
- ML19344A061 + (ML19344A061)
- ML19344A063 + (ML19344A063)
- ML19344A064 + (ML19344A064)
- ML19344A066 + (ML19344A066)
- ML19344A067 + (ML19344A067)
- ML19344A068 + (ML19344A068)
- ML19344A069 + (ML19344A069)
- ML19344A070 + (ML19344A070)