- ML19330A545 + (ML19330A545)
- ML19330A547 + (ML19330A547)
- ML19330A550 + (ML19330A550)
- AECM-80-159, Potential Deficiency Rept Re Nonconformances Associated W/ Calibr Svcs Provided by Computer Sciences Corp. Nonconformances Noted During Util Apr 1980 Audit of Calibr Facility.Final Rept Will Be Submitted by 800822 + (ML19330A551)
- ML19330A552 + (ML19330A552)
- 05000346/LER-1980-053, Forwards LER 80-053/01T-0 + (ML19330A553)
- ML19330A554 + (ML19330A554)
- 05000321/LER-1980-081, Forwards LER 80-081/03L-0 + (ML19330A555)
- ML19330A556 + (ML19330A556)
- ML19330A557 + (ML19330A557)
- ML19330A558 + (ML19330A558)
- ML19330A560 + (ML19330A560)
- 05000346/LER-1980-053-01, /01T-0:on 800709,meeting Held to Discuss Results of Integrated Safety Features Actuation Sys Test.Some of Logic Modules on Sequencer Steps 2,3,4 & 5 Tripped Before Being Blocked.Caused by Design Deficiency + (ML19330A561)
- DD-80-21, Forwards Directors Decision Under 10CFR2.206 (DD-80-21) Denying Antinuclear Group Representing York Request for EIS & Related Fr Notice + (ML19330A562)
- ML19330A564 + (ML19330A564)
- ML19330A565 + (ML19330A565)
- ML19330A567 + (ML19330A567)
- ML19330A568 + (ML19330A568)
- 05000321/LER-1980-081-03, /03L-0:on 800705,w/mode Switch in Run,Drywell Pressure Recorder 1T48-R608 Found Inoperative.Redundant Recorder 1T48-R609 Was Operable.Caused by Component Failure. Transmitter Repaired,Recalibr & Returned to Svc + (ML19330A569)
- 05000346/LER-1980-054-03, /03L-0:on 800627,NI-1 Output Failed to Zero During Fuel Assembly Movement.Assembly Removed & Put in Support Rack.Cause Unknown But May Be Intermittent Grounding Problem or Component Failure.Ground Problems Under Investigatio + (ML19330A570)
- ML19330A571 + (ML19330A571)
- ML19330A572 + (ML19330A572)
- ML19330A573 + (ML19330A573)
- ML19330A575 + (ML19330A575)
- ML19330A576 + (ML19330A576)
- ML19330A577 + (ML19330A577)
- ML19330A579 + (ML19330A579)
- ML19330A581 + (ML19330A581)
- 05000333/LER-1980-058, Forwards LER 80-058/03L-0 + (ML19330A582)
- ML19330A583 + (ML19330A583)
- ML19330A584 + (ML19330A584)
- ML19330A585 + (ML19330A585)
- 05000333/LER-1980-058-03, /03L-0:on 800628,during Normal Shutdown Operations,Functional Tests of Average Power Range Monitor Instruments Found Not Conducted Per Tech Specs.Caused by Manual Scheduling of Computer Outage + (ML19330A586)
- ML19330A587 + (ML19330A587)
- ML19330A588 + (ML19330A588)
- ML19330A590 + (ML19330A590)
- ML19330A591 + (ML19330A591)
- ML19330A593 + (ML19330A593)
- 05000321/LER-1980-077, Forwards LER 80-077/03L-0 + (ML19330A594)
- ML19330A595 + (ML19330A595)
- ML19330A596 + (ML19330A596)
- ML19330A599 + (ML19330A599)
- ML19330A600 + (ML19330A600)
- ML19330A601 + (ML19330A601)
- 05000321/LER-1980-077-03, /03L-0:on 800708,during High Reactor Pressure Instrumentation Functional Test & Calibr,Found That Pressure Switch 1B21-NO23B Actuated in Excess of Tech Specs.Caused by Setpoint Drift.Switch Recalibr & Successfully Tested + (ML19330A602)
- ML19330A603 + (ML19330A603)
- ML19330A604 + (ML19330A604)
- ML19330A605 + (ML19330A605)
- ML19330A606 + (ML19330A606)
- ML19330A607 + (ML19330A607)
- 05000333/LER-1980-057, Forwards LER 80-057/03L-0 + (ML19330A608)