p V,
Firm NRC-618 U.S. NUCLE AR REGUL/-TORY CoMMIS$loN CERTIFICATE OF COMPLIANCE to C R 71 For Radioactive Materiels Packages 1.(al Certificate Number 1.(b) Revision No.
1.(c) Package Identification No.
1.(d) Pages No. 1.(e) Total No. Pages 9030
?
IISA/9030/R( T 1
2
- 2. PREAMBLE 2.lal This certificate is issued to satisfy Sections 173.393a,173.394,173.39s. and 173.396 of the Department of Transportation Hazardous Materials Regulations (49 CFR 170-189 and 14 CFR 103) and Sections 146-19-toa and 146-19-100 of the Department of Transportation Dangerous Cargoes Regulatiore (46 CFR 146-149), as amended.
2.(b)
The packaging and contents described in item s below, rneets the safety standards set forth in Subpart C of Title to. Code of
.f, '
, Federal Regulations, Part 71, Packaging of Radioactive Materials for Transport and Transportation of Radioactive Material Under Certain Conditions."2.
._,y',.,,,
- k. _~.,. _ ;-.
= -. _
.:. :.. a
-~ ;~
n:= "
2.(c)
This artificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation or other applicable regulatory agencies, including the government of any country through or into which the package will be transported.
- 3. This certificate is issued on the basis of a safety analysis report of the package design or application-3.(a)
Prepared by (Name and address):
3.(b)
Title and identification of report or application:
Teledyne Energy Systems Martin Company application dated June 16, 1966, 110 West Timonium Road as supplemented.
x Timonium, MD 21093 71-9030 3,,,
o,,,,, y,,
- 4. CONDITIONS This certificate is conditional upon the fulfilling of the reovirements of Subpart D of 1o CFR 71, as applicable, and the conditions specified in item 5 below.
- s. Description of Packaging and Authorized Contents, Model Number, Fissile Class, Other Conditions, and
References:
(a), Packaging (1) Model Nos.:
MW-3000, Sentinel-3, and Sentinel-8 (2) Description The packages are thermoelectric generators.
The major components include:
the main housing, tungsten shield, housing flange, and electrical connectors.
The approximate dimensions and weights for the Model Nas. are as follows:
Model No.
Dimensions (inches)
Weight (lbs.)
MW-3000, Sentinel-3 24 OD x 23 2,700 Sentinel-8 24 OD x 25 3,200 (3) Drawings The packagings are constructed in accordance with the following Drawing Nos.:
Model No.
Drawings MW-3000, Sentinel 3 Martin Co. Drawing No. 471A1000000 Sentinel-8 Isotopes, Inc. Drawing No. J-30856-003-10000 8007280667
Page 2 - Certificate No. 9030 - hevision No. 2 - Docket No. 71-9030 5.
'(b) Contents (1) Type and form of material Strontiem-90 tita,nate doubly encapsulated in Hastelloy fuel capsule which meet the requirements of special form as defined in 10 CFR 971.4(c).
(2) The maximum quantity of material per package Model No.
Quantity MW-3000, Sentinel-3 25,000 Curies Sentinel-8 40,000 Curies 6.
Eye-bolts shall be removed or covered during transportation to prevent their use as tie-down devices of packages.
7.
The MW-3000, Sentinel-3, and Sentinel-8 shall have their top steel cover plate bolted to the outer wrought steel shield at all times except when maintenance operations are being performed on the generator which require removal of the top steel cover plate.
8.
The packages authorized by this certificate are hereby approved for use under the general license provisions of 10 CFR 571.12(b).
9.
Expiration date:
July 31, 1985.
REFERENCES i
Isotopes, Inc. applications da,ted:
September 15 and 16, 1969; and March 3 and April 20, 1970.
Additional References Required For The Model No. MW-3000 and Sentinel-3 Martin Company application dated June 16, 1966; with supplements dated:
July 22 and August 16, 1966.
Additional References Required For The Model Sentinel-8 1sotopes, Inc. application dated November 5, 1968; with supplement dated:
December 5, 1968.
FOR THE U.S. NUCLEAR REGULATORY COMMISSION Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety Id Date:
i l
--, -.