- ML19294A396 + (ML19294A396)
- ML19294A397 + (ML19294A397)
- ML19294A399 + (ML19294A399)
- ML19294A400 + (ML19294A400)
- ML19294A401 + (ML19294A401)
- ML19294A402 + (ML19294A402)
- ML19294A403 + (ML19294A403)
- ML19294A404 + (ML19294A404)
- ML19294A406 + (ML19294A406)
- ML19294A408 + (ML19294A408)
- ML19294A409 + (ML19294A409)
- ML19294A413 + (ML19294A413)
- ML19294A415 + (ML19294A415)
- ML19294A418 + (ML19294A418)
- ML19294A422 + (ML19294A422)
- ML19294A424 + (ML19294A424)
- ML19294A426 + (ML19294A426)
- ML19294A427 + (ML19294A427)
- ML19294A428 + (ML19294A428)
- ML19294A429 + (ML19294A429)
- ML19294A430 + (ML19294A430)
- ML19294A432 + (ML19294A432)
- ML19294A434 + (ML19294A434)
- ML19294A435 + (ML19294A435)
- 05000318/LER-1978-034, Forwards LER 78-034/03L-0 + (ML19294A437)
- ML19294A438 + (ML19294A438)
- ML19294A439 + (ML19294A439)
- 05000318/LER-1978-034-03, /03L-0 on 781023: in Mode 3 at 500F,12 Main Steam Safety Valve Relief Set Points Were Outside Tolerances of TS 4.7.1;all Were Adjusted & Setpoints Returned to Spec + (ML19294A440)
- ML19294A441 + (ML19294A441)
- 05000334/LER-1978-054, Forwards LER 78-054/03L-0 + (ML19294A443)
- ML19294A444 + (ML19294A444)
- 05000334/LER-1978-054-03, /03L-0 on 781005:During Surveillance Test on Containment High Pressure Bistable,The Setpoint Was 2.3 Lbs Instead of 2.0.Caused by Faulty Elco Connector on Loop Signal Comparator.Comparator Was Replaced + (ML19294A445)
- ML19294A446 + (ML19294A446)
- ML19294A450 + (ML19294A450)
- ML19294A451 + (ML19294A451)
- ML19294A453 + (ML19294A453)
- ML19294A455 + (ML19294A455)
- IR 05000348/1978024 + (ML19294A456)
- ML19294A457 + (ML19294A457)
- ML19294A459 + (ML19294A459)
- ML19294A460 + (ML19294A460)
- ML19294A461 + (ML19294A461)
- ML19294A462 + (ML19294A462)
- ML19294A467 + (ML19294A467)
- ML19294A469 + (ML19294A469)
- 05000348/LER-1978-073, Forwards LER 78-073/03L-0,78-074/03L-0,78-075/03L-0, 78-076/03L & 78-077/03L-0 + (ML19294A470)
- 05000348/LER-1978-073-03, /03L-0 on 781009:Instru Air to Containment Iso Valve Was Declared Inoper When Valve Was Blocked Open to Allow Repair of Control Air Supply Regulator Valve Actuator. Regulator Replaced & Valve Stem Reconnected + (ML19294A472)
- 05000348/LER-1978-074-03, /03L-0:on 780917,during test,1A Motor Driven Aux Feed Pump Failed to auto-start Due to B1F Sequencer Failure. Caused by 205F Agastat Relay Time Delay Setpoint Which Had Drifted.Setpoint Was Adjusted & Retest Performed + (ML19294A473)
- 05000348/LER-1978-075-03, /03L-0:on 781010,review of Data Acquired During Response Time Testing Indicated Possible Faulty Component in 1-2A D/G Output Breaker Control Circuit,Causing Delay in Closure.Fuse on 125 V DC Supply Was Blown.Fuse Replaced + (ML19294A474)
- 05000348/LER-1978-076-03, /03L-0;on 781011,during Operational check,1B Diesel Generator Was Started.B Air Start Sloenoid Valve Stuck Open,Bleeding B Air Receiver Down to 10psig.Valve Disassembled & Parts Cleaned.Unit re-tested + (ML19294A475)