ML19294A444

From kanterella
Jump to navigation Jump to search
Forwards LER#78-054/03L-0
Date released: 11/04/2019 Download: ML19294A444


LER#78-054/03L-0 on 781005:During Surveillance Test on Containment High Pressure Bistable,The Setpoint Was 2.3 Lbs Instead of 2.0.Caused by Faulty Elco Connector on Loop Signal Comparator.Comparator Was Replaced
ML19294A445
Person / Time
Site: Beaver Valley
Issue date: 11/04/1978
From: Werling J
DUQUESNE LIGHT CO.
To:
References
Download: ML19294A445 (1)
Forwards LER#78-054/03L-0
ML19294A443
Person / Time
Site: Beaver Valley
Issue date: 11/04/1978
From: Werling J
DUQUESNE LIGHT CO.
To: GRIER B H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19294A443 (2)